型号: | 3887 |
---|---|
品牌: | CARVER |
原产地: | 美国 |
类别: | 化工 / 化学试验器具和用品 |
标签︰ | 压片机 , 美国压片机 , 全自动压片 |
单价: |
-
|
最少订量: | 1 台 |
全自动压片机,电动液压单元独立设计,并配有直径5英寸的压盘及安全视窗。坚固的侧护板框架结构,保证了压盘的精确定位。"SD"微处理器控制系统,可显示程序设定的压力。升级版的“PD”型控制系统还可以设定泄压压力。25吨的压片机标配直径13毫米的溴化钾模具,40吨的压片机标配31毫米的模具,适用于X荧光样品的制备。(您还可以根据需要,订购40毫米的模具)
型 号 | 最高压力 (吨) (磅) | 压盘尺寸 (英寸) | 模具直径 (毫米) | 压盘行程 (英寸) | 压盘间距 (英寸) | 底座尺寸长x宽 (英寸) | 高 (英寸) | 重量 (磅) |
3887 | 25 50,000 | 5 | 13 | 1 | 1.5-7.25 | 31.5x22.75 | 22 | 400 |
4387 | 40 80,000 | 5 | 31 | 1 | 1.5-7.25 | 34x22.75 | 26 | 500 |
3 Sets of two Connectors (in- and outlet)
for Base plate
6 N9306848
Ultra Clean Connector Set - 1/8" SS
3 Sets of two Connectors (in- and outlet)
for Base plate
6 N9306849
Ultra Clean High Flow Connector Set -
Brass 1/4"
3 Sets of two Connectors (in- and outlet)
for Base plate
6 N9306850
Ultra Clean High Flow Connector Set -
1/4" SS
3 Sets of two Connectors (in- and outlet)
for Base plate
6 N9306851
Ultra Clean Flush Cap Replacement Set
2 Flush Caps for Base Plate
2 N9306852
Ultra Clean High Flow Flush Cap
Replacement Set
2 Flush Caps for High Flow Base Plate
2 N9306853
Ultra Clean Base Plate O-ring
Replacement Set
Two sets of 10 O-rings for Base plate
20 N9306854
Ultra Clean Wall-mounting Bracket Set
Suitable for genuine Ultra Clean Base plates
N9306855
Ultra Clean 0.5 Micron Particle Filter (1/4" Brass) N9306856
Ultra Clean 0.5 Micron Particle Cup Filter Pack
Replacement Filter Element - pack of 12
N9306857
N9303963
Oxygen 850 cc <1 ppb
Water
Hydrocarbons
Replacement cartridge for oxygen, water
and hydrocarbons
N9303964
N9306135
Oxygen 1000 cc <1 ppb
Water
Hydrocarbons
and higher)
Purification System – 3-Head All-Steel System N9306135
Cartridge Set – Gas Purification All System Cartridge
(Replacement)
N9306136
Cartridge – Gas Purification Moisture Replacement N9306137
Cartridge – Gas Purification Hydrocarbon Replacement N9306138
Cartridge – High-Capacity O2
Replacement N9306004
Hardware – Gas Purification Manifold/Mtg for bench
or wall
N9306140
N9301178
N9301192 N9301179
N9301208
N9301191
N9301193
Helium 1.0 x 10-5
Red
Hydrogen* 1.0 x 10-5
Red
Nitrogen 1.4 x 10-3
Yellow
Argon 1.0 x 10-4
Yellow
Carbon Dioxide 1.0 x 10-4
Yellow
Portable Electronic Leak Detector N9306089
Soft Carrying Case N9306142
Probe (Fine Tip) N9306063
Response time
Accuracy ±2%, or ±
Laser Sighting Yes
MiniTemp MT4 N9306074
Tools Come in a Tool Box for Easy Storage and Use N9301327
Shipped in a Plastic Tool Box for Convenient Storage N9301328
Digital Bubble Flow Meter N9302974
Replacement Glass for Digital Bubble Flow Meter N9303429
PerkinElmer Electronic Flowmeter 1000 N9307029
Two-stage 00230522
Three-stage N9300081
Stand N9303314
FlowMark™
Electronic Flowmeter N9307086
Soft Carrying Case N9306142
PSS Splitless Glass Liner Siltek Deactivated Surface Liner
(with wool) – General purpose use, ideal for chlorinated
pesticides analyses
2 4 86.2 5 N6502001
Split Glass Liner Siltek Deactivated Surface Liner (with wool) –
Universal liner for general purpose analyses. Surface provides
inertness over a wide sample pH range. Wool can be adsorp-
tive if fibers are broken
4 6.2 92.1 5 N6121020
Split Glass Liner (with wool) – Universal liner for general
purpose analyses
4 6 92.1 5 N6502009
Split Siltek Deactivated Glass Liner (with wool) – Universal
liner for general purpose analyses. Deactivated surface provides
minimal bleed and inertness over a wide sample pH range
4 6 92.1 5 N6502010
Clarus Cup
molecular weight compounds. Sample vaporization is aided by
tortuous flow path and minimizes molecular weight discrimina-
tion. Difficult to clean
4 6 92.1 5 N6502011
Clarus Cyclosplitter Glass Liner – Patented cylindrical design
for dirty samples, easy to clean and allows many injections
before cleaning is required. Not recommended for large
volume injections
4 6 92.1 5 N6502012
Uniliner Deactivated Glass Liner (with wool) – Universal liner
for general purpose analyses
4 6.2 92.1 5 N6121022
Clarus Splitless Glass Liner – Low volume sample analyses,
beneficial with headspace and purge/trap
1 6.2 92.1 5 N6502006
Quartz Liner for Splitless Operation (ships with instrument) –
Standard injector liner
2 6.2 92.1 1 N6121002
Glass Liner for Splitless Operation – Universal liner for general
purpose analyses
2 6.2 92.1 1 N6101372
Deactivated Glass Liner for Splitless Operation (with wool) –
Good for analyses of trace samples
2 6.2 92.1 5 N6121021
Siltek Deactivated Liner (with wool) for Splitless Operation
– Optimum sample dispertion for active samples. Surface
provides inertness over a wide sample pH range. Wool can be
adsorptive if fibers are broken
2 6.2 92.1 5 N6502004
Quartz Liner for Split Operation – Good for large volume
injection samples
4 6.2 92.1 1 N6121001
Glass Liner for Split Operation – Universal liner for general
purpose analyses
4 6.2 92.1 1 N6101052
Siltek Deactivated Double Gooseneck Glass Liner (with wool)
– Optimum sample dispertion for active samples. Decreases
breakdown of active compounds such as endrin and DDT.
Chamber contains sample vaporization cloud. Not suitable for
PPC systems
4 6.2 92.1 5 N6502003
Cyclo Double Gooseneck Liner for
design for large volume and trace dirty samples. Decreases
injection port discrimination. Cannot be packed with wool and
more difficult to clean
4 6.2 92.1 5 N6502005
Zero Dilution Glass Outer Liner – Ideal for trace HS work.
Use in conjunction with N1011446
2 6.3 90 1 N1011445
Zero Dilution Glass Inner Liner – Ideal for trace HS work.
Use in conjunction with N1011445
2 6.3 90 1 N1011446
Quartz Liner for Splitless operation (ships with instrument) –
Excellent liner for low volume analyses
1 4 86.2 1 N6121006
NEW! Siltek Deactivated Glass PSS Liner – Used for low
volume trace sample analyses
1 4 86.2 5 N6502000
Quartz Liner for
Approved PerkinElmer standard injector liner
2 4 86.2 1 N6121004
NEW! Siltek Deactivated Glass Liner for
wool) – Maximum inertness and packed with wool gives opti-
mum sample dispersion. Surface provides inertness over wide
sample pH range. Wool can be adsorptive if fibers are broken
2 4 86.2 5 N6502001
NEW! Siltek Deactivated Glass Liner for
Max. inertness gives optimum sample dispersion.
Deactivated surface provides minimal bleed and inertness
over a wide sample pH range
2 4 86.2 5 N6502002
Zero Dilution Outer Liner –Use in conjunction with N1011446 2.8 4 83 1 N1011447
Zero Dilution Inner Liner –Use in conjunction with N1011447 2 73 1 N1011446
On-column Glass Liner 2.4 4 86.2 1 N6101539
Liner/Hour Glass for POC Injector 2.4 4 19.05 1 N6101703
Quartz
Quartz
Drilled Uniliner (hole on top) – Excellent liner for high sample
recovery and linearity, recommended for aqueous injections.
Good for PPC equipped GCs
4 6.2 92.1 5 N6121022
NEW! Drilled Uniliner (hole on bottom) – Recommended for
analysis in which compounds of interest could be affected by
a tailing solvent peak. Good for PPC equipped GCs
4 6.2 92.1 5 N6502013
NEW! Gooseneck Drilled Uniliner (hole on top) – Use for trace,
active samples, high recovery and linearity
4 6.2 92.1 5 N6502014
NEW! Gooseneck Drilled Uniliner (hole on bottom) – Use for
trace, active samples, high recovery and linearity
4 6.2 92.1 5 N6502015
NEW! Open Top Uniliner (with wool) – Packed with fused silica
wool, highly recommended for high molecular weight active
samples. The fused silica wool traps dirt and sample residue
4 6.2 92.1 5 N6502016
NEW! Cyclo Uniliner – Cylindrical design for high molecular
weight samples provides an excellent vaporization surface.
Spiral traps dirt reducing further residue sample interaction
4 6.2 92.1 5 N6502017
Wide-Bore Column Glass Liner 6 4 92.1 1 N6101375
Wide-Bore Column On/Off Quartz Liner 6 4 92.1 1 N6121003
PSS deactivated glass liners with deactivated wool. Narrow
bore and quartz wool increase volatilization and reproducibility
2 4 86.2 5 N9306232
Capillary splitless deactivated glass liners with
deactivated wool.
4 6.2 92.1 5 N9306233
Capillary splitless deactivated glass liners with
deactivated wool.
4 6.2 92.1 1 N9306234
Capillary splitless deactivated glass liners with
deactivated wool.
4 6.2 92.1 5 N9306235
Capillary splitless deactivated glass liners with deactivated
wool. Quartz wool is used to fully vaporize the sample.
4 6.2 92.1 5 N9306236
PSS Splitless deactivated glass liners with deactivated
wool 5/pk.
1.25 4 86.2 5 N9306237
50 µL Syringe, Metal Plunger
5 µL Syringe, Metal Plunger PTFE-tipped Seal
N6101390
5 μL Syringe, Metal Plunger PTFE-tipped Seal
N6103240
5 μL Syringe, Metal Plunger PTFE-tipped Seal
N6103241
5 µL Syringe, Metal Plunger
5 µL On-column Syringe Metal Plunger
N6101380
0.5 µL Low Injection Volume Syringe, Metal Plunger
N6101252
0.5 μL Low Injection Volume Syringe Metal Plunger
N6103242
0.5 μL Low Injection Volume Syringe Metal Plunger
N6103243
0.5 µL Low Injection Volume Syringe, Metal Plunger
N6101253
0.5 µL 25 1 N9302231
1.0 µL 22 1 00230177
1.0 µL 261
1 00230111
2.0 µL 25 1 N9302235
10 µL 1 #2 N9302210
25 µL 1 #2 N9302211
50 µL 1 #2 N9302212
100 µL 1 #2 N9302213
10 µL 1 #2 N9302222
25/50/100 µL 22S
250 µL 22S
10 µL3
1 #2 00230523
10 µL2
6 #2 N9302230
25 µL 1 #2 N9302202
25 µL 1 #3 09904823
50 µL 1 #2 N9302203
50 µL 1 #3 09904941
Mains Plug Pack
N9304500
Mains Plug Pack
N9304501
Mains Plug Pack
N9304502
Mains Plug Pack
N9304503
6.4 Volt Lithium Ion
Bench-top Vial Crimper 1 N6621006
2 mL
2 mL
2 mL
2 mL
Glass Vials with Write-On Patch and Fill Lines
100 N9306223
2 mL
Glass Vials with Write-On Patch and Fill Lines
100 N9302679
Rubber Septa
1,000 03300806
Silicone Septa
100 N9306228
PTFE Septa
100 N9306229
Rubber Septa
100 N9306230
Rubber Septa
100 N9302686
Rubber Septa
100 N9302684
Rubber Septa
100 N9302685
Rubber Septa
100 N9306015
Viton® Septa
1,000 N9302784
2 mL
with hole
100 N9303441
100 N9303442
2 mL
2 mL
2 mL
Write-On Patch and Fill Lines
100 N9307801
2 mL
Write-On Patch and Fill Lines
100 N9307802
Silicone Septa
100 N9306203
2 mL
2 mL
Rubber Septa
100 N9306206
2 mL
2 mL
with Write-On Patch and Fill Lines
100 N9306207
2 mL
with Write-On Patch and Fill Lines
100 N9306208
Snap Cap
100 N9303416
Snap Cap
100 N9303417
Cap for Waste and Wash Vials (
Clear Waste and Wash Vial 4 mL (
Clear Waste and
Septa for Waste Wash Vials (for use with
Viscous or Toxic Samples)
50 N9302780
Diffusers for Waste and
Diffusers are sold exclusively by PerkinElmer.
The conical shape allows the needle to
penetrate into solvent or waste. Reduces
spillage and large losses through evaporation.
1 N6101276
200-μL Low-Volume Clear Glass Insert 1,000 N9302681
Vial Support for Insert 500 N9302682
Pulled Point with Bottom Spring, 250 μL
Usable Volume
100 N9300703
400 μL Usable Volume
100 N9300704
Use with:
w/White “P” Icon w/Patch
w/White “P” Icon w/Patch
w/Black“P” Icon
w/Black “P” Icon
w/Black “P” Icon
w/Black “P” Icon
N9306057
N9306053
N9303418
N9306231北京博德恒悦科贸有限公司 | |
---|---|
国家/地区︰ | 北京市海淀区 |
经营性质︰ | 贸易商 |
联系电话︰ | 62883589 |
联系人︰ | 白小姐 (职员) |
最后上线︰ | 2017/01/17 |