TEK DRIVE TDS-V8 AC MOTOR DRIVE/TDS-V8-H5P5E
Product Description
Input Voltage Class |
440V class 3Phase |
Model |
TDS-V8-H |
0P7 |
1P5 |
2P2 |
3P7 |
5P5 |
7P5 |
11 |
15 |
18 |
22 |
30 |
37 |
45 |
55 |
75 |
Max. Applicable Motor |
HP |
1 |
2 |
3 |
5 |
7.5 |
10 |
15 |
20 |
25 |
30 |
40 |
50 |
60 |
75 |
100 |
Motor Output(CT)* |
kW |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
Weight (kg) |
2 |
2 |
2.4 |
2.4 |
5.5 |
5.5 |
13.1 |
13.1 |
24.5 |
24.5 |
24.5 |
24.5 |
24.5 |
46 |
46 |
Power Output |
Rated Output Capacity(kVA) |
2.1 |
2.7 |
4 |
7.5 |
10.1 |
13.7 |
20.6 |
27.4 |
34 |
41 |
54 |
68 |
82 |
110 |
138 |
Rated Output Current(A) |
2.6 |
4 |
4.8 |
8 |
12 |
16 |
24 |
32 |
40 |
48 |
64 |
80 |
96 |
128 |
165 |
Max. Output Voltage |
3Phase 380V~460V |
Max. Output Frequency(Hz) |
Through parameter setting ( 0 Hz to 400Hz) |
Power Source |
Rated Voltage, Frequency |
3Phase 380V~460V,50/60Hz |
Allowable Voltage Fluctuation |
-15% ~ +10% |
Allowable Frequency Fluctuation |
±5% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Control Characteristics |
Operation Mode |
LED Operator or LCD Operator |
Control Mode |
Sine PWM |
Frequency Control Range |
0.1Hz~400Hz |
Frequency Accuracy(varied with temperature) |
Digital Command:±0.01%(-10 ~ +40℃),
Analog Command:±0.1% (25℃ ±10℃) |
|
Frequency Command Resolution |
Digital Command:0.01Hz,
Analog Command:0.06Hz/60Hz |
|
Frequency Output Resolution |
0.01Hz |
|
Overload Resistibility |
150% Rated Current for 1 Minute(CT) ; 120%Rated Current for 1Minute(VT) |
Frequency Setting Signal |
DC 0 ~ +10V / 4 ~ 20mA |
Acc./Dec. Time |
0.0~6000.0 sec (Accel/Decel Time Can be Set Independent) |
Voltage-Frequency Characteristics |
V/F Curve Can be Set Through Paramenter Setting(16Types) |
|
Regeneration Torque |
100%,2%ED,5 sec |
Main Control Function |
Auto Torque Boost, Slip Compensation, Restart After Momentary Power Loss, Energy-Saving, |
PID Control, RS-485 Communication, Simple PLC Function, Sensorless Vector Control |
Extra Function |
Up/Down Operation, 4 Different Sets of Fault Status Record (Including Latest One), |
|
cumulative Power On & Operation Hour Memory, Energy Savings Function, |
|
MODBUS Communication, Multiple-Pulse Output Ports, etc. |
Protection Function |
Stall Prevention |
During Acceleration/Decelearation and constant speed opearation |
Current Level can be Selected During Acceleration and Constant Speed Operation |
During Deceleration, Stall Prevention can be Enabled or Disabled) |
Instantaneous Overcurrent (OC) |
Stopped if above 200% Rated Current |
|
|
|
|
|
|
|
Inverter overloads Protection(OL2) |
Stopped if above 150% Rated Current for 1 Minute |
|
|
|
|
|
|
|
|
Motor Overload (OL1) |
Electronic Overload Curve Protection |
|
|
|
|
|
|
|
|
Over voltage(OV) |
Motor Coasts to Stop if VDC > 410V (230V) or VDC > 820V (460V) |
|
|
|
|
|
|
|
|
Low voltage(UV) |
Motor Coasts to Stop if VDC < 200V (230V) or VDC < 400V (460V) |
|
|
|
|
|
|
|
|
Momentary Power Loss Ride-Through time |
Motor Coasts to Stop after Momentary Power Loss Lasting > 15ms |
|
|
|
|
|
|
|
|
Overheat (OH) |
Protection by Thermistor |
|
|
|
|
|
|
|
|
Grounding Protection (GF) |
Protection by the DC Current Sensor |
|
|
|
|
|
|
|
|
Charge Indication |
Light when the DC Bus Voltage ≧50V |
Payment Terms: | T/T,WU |
specifications: | TDS-V8-H5P5E 380 ~ 460V 7.5Hp / 5.5kW |
Export Markets: | worldwide |
Payment method: | T/T,WU |
Min Order: | 1 pc |
Ship Date: | 3 days after payment |
| |
Product Image
Img 1
Send Inquiry to this Member
Related Products of this Company
This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please
click here.
China Suppliers Quick Searching:
,