Home > Products > Electronics & Electricity > Other Electrical & Electronic

JMDM-COM40MR/MT serial port control 40-channel output 1JMDM-COM40MR/MT serial port control 40-channel output 2JMDM-COM40MR/MT serial port control 40-channel output 3JMDM-COM40MR/MT serial port control 40-channel output 4JMDM-COM40MR/MT serial port control 40-channel output 5
  • JMDM-COM40MR/MT serial port control 40-channel output 1
  • JMDM-COM40MR/MT serial port control 40-channel output 2
  • JMDM-COM40MR/MT serial port control 40-channel output 3
  • JMDM-COM40MR/MT serial port control 40-channel output 4
  • JMDM-COM40MR/MT serial port control 40-channel output 5

JMDM-COM40MR/MT serial port control 40-channel output

Model:JMDM-COM40MR/MT
Brand:JMDM
Origin:Made In China
Category:Electronics & Electricity / Other Electrical & Electronic
Label:relays , relay controller , controller
Price: -
Min. Order:1 pc
Inquire Now

Member Information

Detail

Product Description

 1. jmctrl (at) msn (dot) cn.JMDM-COM40MR/MT serial port brief using explanations (Use the presented of universal serial control software)

1) Connecting the wiring between the controller and equipment, the serial port communication line between the computer 


and controller according to the instructions attach to the wiring diagram;


2) The default address is 00 when the serial port control one controller; 4 DIP switches need to dial up all, fully OFF


 state represent the address is 00. (Remark: having marks at the DIP switch ---- arrow down means ON , that is to dial 


down means the ON state, the dial on means OFF, state).


3) After careful examination and correct, connected the power supply of the controller; AC and DC universal, regardless 


of positive and negative.


4) Connect the serial port control software and supplied with the products.


Method one: Double-click the small light bulb icon directly.


Path: serial port control 40-channel output PC monitoring procedure \ serial port control 40-channel output \ Support \ 


serial port control40-channel relay output.exe file (that is small light bulb icon).


Method two: Double-click setup.exe file, install the supplied universal serial port control software.


Path: serial port control 40-channel output PC monitoring procedure \ serial port control 40-channel output \ setup.exe 


\ open the PC software can click the control output point.


2. Customers can according the communication protocol to write the PC serial port control software, through the online 


download of the serial port deb ing assistant testing to sending the characters directly.


1) JMDM-COM40MR/MT serial port communication protocol with address bits


Baud rate: 9600; parity: none data bits: 8 stop bits: 1


Computer sending example:


 


 


4F 28 30 30 2c 30 30 31 2c 30 29    ASCII code;


O(00,001,0) function: the first output point of the controller’s shutdown address is 00


O(00,001,1) function: the first output point of the controller’s open address is 00


The first output point of the controller’s open address is 00 and the instructions example is: O (00, 001, 1), specify 


of the communication protocol:


Send characters O ( 00 . 001 . 1 )


Function meaning instructions Communication head Controller address separator The first 


channel relay separator The output state is open Communication tail


ASCII code 0x4F 0x28 0x300x30 0x2c 0x300x300x31 0x2c 0x31 0x29


2. Fully open and fully close instructions example


1. The fully open instructions example of the controller for the address is 00: O (00, 000, 1)


The fully close instructions example of the controller for the address is 00: O (00, 000,0)


The corresponding relationship between Characters and ASCII code


The corresponding ASCII code for O is: 0x4F


The corresponding ASCII code for R is: 0x52


The corresponding ASCII code for S is: 0x53


The corresponding ASCII code for P is: 0x50


The corresponding ASCII code for (is: 0x28


The corresponding ASCII code for, is: 0x2C


The corresponding ASCII code for) is: 0x29


The corresponding ASCII code for E is: 0x45


The corresponding ASCII code for M is: 0x4D


The corresponding ASCII code for J is: 0x4A


The corresponding ASCII code for C is: 0x43


After-the sales the service


   1) Since the date of the product sold under the normal use of the hardware failure, one year warranty, repair cost 


is charged only after the warranty period. Due to natural forces and man-made damage are failures to use of the use, 


inappropriate operation, and overhaul.


Product Image

JMDM-COM40MR/MT serial port control 40-channel output 1
Img 1
JMDM-COM40MR/MT serial port control 40-channel output 2
Img 2
JMDM-COM40MR/MT serial port control 40-channel output 3
Img 3
JMDM-COM40MR/MT serial port control 40-channel output 4
Img 4
JMDM-COM40MR/MT serial port control 40-channel output 5
Img 5

Send Inquiry to this Member

Shenzhen Jingmin Digital Machine Co.,Ltd.

5/F, Buiding C, Fenda Technology Creative Park,Sanwei, Xixiang, Baoan,

Phone:
86-0755-23056703
Fax:
86-0755-29355820
Contact:
Crystal (foreign trade clerk)
Mobile:
13392401830

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Other Electrical & Electronic Made In China Products

,  

Other Electrical & Electronic China Suppliers and China Manufacturers