Model: | ALHME NF1200 |
---|---|
Brand: | AL HIKMA MEDICAL EQUIPMENT |
Origin: | Made In Qatar |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | DEFIBRILATOR IPAD , SEMI AUTOMATED , FULLY AUTOMATED |
Price: |
-
|
Min. Order: | - |
Last Online:27 Jun, 2012 |
Physical | ||
Size | 2.75 in high X 8.66 in wide X 10.23 in deep
(70mm high X 220 mm wide X 260 mm deep) |
|
Weight | Approximately 4.84 lbs (2.2 kg)
with battery pack installed |
|
Environmental | ||
Operating Conditions | Temperature | 32˚F to 110˚;F (0˚C to 43 ˚C) |
Humidity | 5 % to 95 % (non-condensing) | |
Storage Conditions | Temperature | 32˚F to 110 ˚F (0 ˚C to 43 ˚C) |
Humidity | 5 % to 95 % (non-condensing) | |
Shock/Drop/Abuse Tolerance | Meets IEC 60601-1 clause 21 (Mechanical Strength) | |
Vibration | Meets EN1789 random and swept sine, road ambulance specification in operating and standby states. | |
Sealing | IEC 60529: IP54 | |
ESD | Meets IEC 61000-4-2:2001 | |
EMI (Radiated) | Meets IEC 60601-1-2 limits, method EN 55011:1998+ A1:1999 +A2:2002, Group 1, Class B | |
EMI (Immunity) | Meets IEC 60601-1-2 limits, method EN 61000-4-3:
2001 Level 3 (10V/m 80MHz to 2500MHz) |
|
Defibrillator | ||
Operating Mode | Semi-automated | |
Waveform | e-cube biphasic (Truncated exponential type); impedance compensated | |
Energy | 200 Joules nominal into a 50Ω load | |
Shock Energy Accuracy | Within ±3% (150J into 50Ω) | |
Charge Control | Automatic by Software (Arrhythmia Detection System and Charging Control) | |
Charge time from “Shock Advised” | < 14 seconds, typical | |
Shock to Shock cycle time | < 15 seconds, typical, including analysis | |
Charge complete indicator | * Text prompt (PRESS THE FLASHING ORANGE BUTTON, NOW)
* flashing backlight of SHOCK button * beep from the beeper |
|
Disarm | Once charged, the NF1200 disarms if:
* Patient’s heart rhythm changes to non-shockable rhythm, or * The SHOCK button is not pressed within 15 seconds after the NF1200 is armed, or * The ON/OFF button is pressed to turn OFF the NF1200, or * The defibrillator pads are removed from the patient or the pads connector is disconnected from the NF1200 |
|
Defibrillator, continued | ||
Shock Delivery | Shock is delivered if the SHOCK button is pressed while the NF1200 is armed. | |
Shock Delivery Vector | Via adult defibrillator pads in the anterior-anterior (Lead II) position or via Reduced-energy pediatric pads in the anterior-posterior position. | |
Patient Isolation | Type BF | |
ECG Acquisition | ||
Acquired ECG Lead | Lead II | |
Frequency Response | 1 Hz to 30 Hz EMS Mode
0.3 Hz to 40 Hz Monitoring Mode |
|
ECG Analysis System | ||
Function | Determines the impedance of the patient and evaluates the ECG of the patient to determine whether it is shockable or non shockable | |
Impedance Range | 25Ω to 175Ω | |
Shockable Rhythms | Ventricular Fibrillation or Fast Ventricular Tachycardia | |
Non Shockable Rhythms | ECG rhythms other than Ventricular Fibrillation or Fast Ventricular Tachycardia | |
Sensitivity & Specificity: | Meets AAMI DF39 guidelines | |
Controls, Indicators, and Prompts | ||
Controls | Power On/Off Button,
i-Button, Shock Button |
|
Indicators | State LED, Graphical Rescue Guide LED | |
Audio Speaker | Provides voice prompts | |
Beeper | Provides various audible indications | |
Low Battery Detection | Automatic during daily testing and Power ON and runtime testing | |
Low Battery Indicator | State LED and Voice Prompt | |
Prompts | Voice prompts guide the user throughout a rescue operation | |
Self-Tests | ||
Automatic | * Power On Self-Test / Run Time Self-Test
* daily / weekly/ monthly |
|
User Initiated | Battery Insertion Test | |
Battery Pack | ||
Battery Type | 12 Volt DC, 4.2 Ah, lithium manganese dioxide, disposable long-life primary cell. | |
Capacity | Minimum 200 shocks or 4 hours of operating time. | |
Temperature Range | -40 °F to 140 °F (-40 °C to 60 °C) | |
Defibrillator Pads (CUA0512F) | ||
Type | self-adhesive, disposable, non-polarized defibrillation pads | |
Adult Pads | Defibrillation pads for patients 8 years of age and older or 55 lbs. (25 kg) and over. | |
Surface Area | Adult : 110cm2 each | |
Cable Length | 1.5m | |
Data Recording and Transmission | ||
Infrared | Wireless transmission of event data to PC through IrDA port. | |
Data Stored | First 40 minutes of ECG and the entire incident’s events and analysis decisions. |