Model: | 1.5KW-110KW |
---|---|
Brand: | Qma |
Origin: | Made In China |
Category: | Electronics & Electricity / Electric Control System |
Label: | elevator control , ac drives , inverter |
Price: |
US $95
/ pc
|
Min. Order: | 1 pc |
Last Online:29 Nov, 2022 |
INTRUDUCTION]
Q-7000 series of brilliant inverters for operation of elevators and escalators are designed to have a lot of exclusive features including Q-7000-EC especially for escalator, Q-7000-EL and Q-7000-IP especially for elevator.
Q-7000 series are all the type adopting IGBT’s PWM control and current vector control, V/F control. Q-7000 series have the function such as connection-point-memory & DC0-10V EASY TUNING, loading compensation for start-up torque, and manual vernier adjustment correcting. High efficiency and safe function, 300% torque compensation. Monitor torque compensation output of the inverter at anytime so as to reduce the shocking the elevator during running. The series of products has easy tuning function to the motor parameters and are complied with the regulation of GB, with braking unit (for≤45kw) and speed feedback unit.
Q-7000-EC is for open loop control without built in PG card, especially used for escalator with brilliant performance by long life design and support RS-485 communication port.
Q-7000-EL is used for geared asynchronous motor. PG card is built in for customer to realize the high fine speed control. Q-7000EL support standalone signal, frequency division, isolated signal, and open collector output functions for Encoder. 200% of rated current for 10 seconds. Speed control accuracy is nominal 1:100 and could reach 1:1000 with PG.
Q-7000 IP is used for gearless synchronous motor. It also support standalone single, frequency division, isolated signal and open collector output functions for Encoder. Q-7000IP supports Line drive 8192 C/T. Its ultra-slim design is adequate for machine room-less elevator. It combines 32- digit vernier-adjustment current vector control and stochastic PWM control. The ultra-low noise, with adjustable wave frequency, carrier frequency 2k-15k is adjustable.
All of Q-7000 series support the RS-485 communication port and other more functions that customers would find most necessary in elevator controls to provide an inverter that delivers performance which fits the elevator systems.
[FEATURES]
Q7000-EC inverter Special for Escalators
*Adopt IGBT’s PWM control
*Current vector control, V/F control
*Built-in connection-point-memory & DC0-10V EASYTUNING, loading compensation for start-up torque and manual vernier-adjustment correcting function
*With high efficiency and safety function, 300% torque compensation, and monitor the torque compensation output of the inverter at any moment
*With EASYTUNING function of the motor parameters
*The series of products are complied with the regulation of GB, with built-in braking unit (for≤45kw )
*Built-in speed feedback unit
Q7000-EL Asynchronous inverter Special for Elevator
*Adopt IGBT’s PWM control
*Current vector control, V/F control
*Support standalone signal, frequency division, isolated signal, and open collector output functions for ENCODER
*Built-in connection-point-memory & DC0-10V EASYTUNING, loading compensation for start-up torque and manual vernier-adjustment correcting function
*With high efficiency and safety function, 300% torque compensation, reducing the vibration of the elevator during its running.
*With EASYTUNING function of the motor parameters
*The series of products are complied with the regulation of GB, and with built-in braking unit (for≤45kw )
*Built-in speed feedback unit
Q7000-IP Synchronous inverter Special for Elevator
*Current vector control, V/F control
*Support standalone signal, frequency division, isolated signal, and open collector output functions for ENCODER
*Self-correcting compensation function for start-up torque and manual vernier-adjustment correcting, improving the comfort of elevator
*Support LIN DRIVE 8192C/T
*Ultra-slim design is adequate for room-less elevator
Multiple modes enable the control more precise, including jog control, speed adjustment, and analog speed control etc
*Combine 32-digitcurrent vector control of vernier-adjustment with stochastic PWM control
*Ultra-low noise, with adjustable wave frequency, carrier frequency of 2 KHz-15 KHz adjustable
*With built-in braking unit (for≤45kw )
*Built-in speed feedback unit
[SPECIFICATIONS]
440V Class
|
|||||||||||||||||
Type
|
HP
|
2
|
3
|
5
|
7.5
|
10
|
15
|
20
|
25
|
30
|
40
|
50
|
60
|
75
|
100
|
150
|
|
Rated Output
|
Motor power
|
KW
|
1.5
|
2.2
|
3.7
|
5.5
|
7.5
|
11
|
15
|
18.5
|
22
|
30
|
37
|
45
|
55
|
75
|
90
|
Rated power
|
KVA
|
3.7
|
4.7
|
6.1
|
11
|
14
|
21
|
26
|
31
|
37
|
50
|
61
|
73
|
98
|
130
|
170
|
|
Rated current
|
A
|
4.8
|
6.2
|
8
|
14
|
18
|
27
|
34
|
41
|
48
|
65
|
80
|
96
|
128
|
165
|
224
|
|
Output voltage
|
V
|
Three-phase 380/415/440/460V(Proportional to input voltage )
|
|||||||||||||||
Max. output frequency
|
Up to 400Hz available by programming
|
||||||||||||||||
Power
|
Rated voltage and Frequency
|
Three-phase 380~460V, 50Hz/60Hz
|
|||||||||||||||
Allowable voltage fluctuation
|
+10%~-15%
|
||||||||||||||||
Allowable frequency fluctuation
|
±5%
|
||||||||||||||||
220V Class
|
|||||||||||||||||
Type
|
HP
|
2
|
3
|
5
|
7.5
|
10
|
15
|
20
|
25
|
30
|
40
|
50
|
60
|
75
|
100
|
150
|
|
Rated Output
|
Motor power
|
KW
|
1.5
|
2.2
|
3.7
|
5.5
|
7.5
|
11
|
15
|
18.5
|
22
|
30
|
37
|
45
|
55
|
75
|
110
|
Rated power
|
KVA
|
3.0
|
4.2
|
6.7
|
9.5
|
13
|
19
|
24
|
30
|
37
|
50
|
61
|
73
|
98
|
110
|
160
|
|
Rated current
|
A
|
8
|
11
|
17.5
|
25
|
33
|
49
|
64
|
80
|
96
|
130
|
160
|
183
|
224
|
300
|
450
|
|
Output voltage
|
V
|
Three-phase 200/220/230/240V (Proportional to input voltage)
|
|||||||||||||||
Max. output frequency
|
Up to 400Hz available by programming
|
||||||||||||||||
Power
|
Rated voltage and Frequency
|
Three-phase 220~2400V, 50Hz/60Hz
|
|||||||||||||||
Allowable voltage fluctuation
|
+10%~-15%
|
||||||||||||||||
Allowable frequency fluctuation
|
±5%
|
||||||||||||||||
Control Feature
|
Control method
|
Sine wave PWM dynamic current vector control (with V/F control , torque vector control, PG feedback vector control )
|
|||||||||||||||
Speed control accuracy
|
±0.2%
|
[±0.02% with PG]
|
|||||||||||||||
Speed control range
|
1:100
|
[1:1000 with PG]
|
|||||||||||||||
Speed control response
|
10Hz
|
[30Hz with PG]
|
|||||||||||||||
Starting torque
|
150%/0.5Hz
|
[200%/0Hz with PG]
|
|||||||||||||||
Torque response
|
20Hz, 50ms
|
[40Hz, 25ms with PG]
|
|||||||||||||||
Torque accuracy
|
±5%
|
||||||||||||||||
Torque limit
|
4 kinds of vector control methods by parameter setting
|
||||||||||||||||
Frequency controlling range
|
0.01~400 Hz
|
||||||||||||||||
Frequency accuracy
|
Digital signal reference: ±0.01% (-10℃~ +40℃), analogue reference: ±0.1% (25℃±10℃)
|
||||||||||||||||
Frequency setting resolution
|
Digital signal reference: ±0.01Hz (Below 100Hz), analogue reference: ±0.03Hz/60Hz (12bit)
|
||||||||||||||||
Output frequency resolution
|
0.001 Hz
|
||||||||||||||||
Frequency setting signal
|
Analogue reference DC-10~+10V(20KΩ),4~20Ma(250Ω)
|
||||||||||||||||
Braking torque
|
±20 % ( approximately 150% with braking resistor option)
|
||||||||||||||||
Accelerating/decelerating time
|
0.01-6000.0s (Accelerating/Decelerating time setting independently, 4 kinds of time controlling modes available)
|
||||||||||||||||
Overload capability
|
150% of Rated torque current for 60s, 200% of rated torque current for 5s
|
||||||||||||||||
Communication
|
RS-485
|
||||||||||||||||
Running/stopping setting
|
Operator, RS-485, Control circuit terminal (frequency setting and parameter access control available by computer)
|
||||||||||||||||
Affiliated control function
|
Parameter save operator, RS-485, torque control, speed control, PID control, multiple-speed control, couple control, etc.
|
||||||||||||||||
Protective Function
|
Instantaneous Overcurrent
|
Motor coasts to stop at approx. 200% rated output current.
|
|||||||||||||||
Motor overload protection
|
Electronic thermodynamic electric protection
|
||||||||||||||||
Fuse protection
|
Motor coasts to stop
|
||||||||||||||||
Momentary power loss
|
Continue to run during power loss less than 2s (standard)
|
||||||||||||||||
Overload
|
150% of rated output current for 60s, 200% of rated output current for 5s, motor coasts to stop
|
||||||||||||||||
Fin Overheat
|
Thermocouple temperature switch protection
|
||||||||||||||||
Stall prevention
|
Stall prevention during acceleration/deceleration and constant speed operation
|
||||||||||||||||
Ground fault
|
Protected by electronic circuit
|
||||||||||||||||
Power charge protection
|
Indicates until the main circuit voltage reaches 50 V
|
||||||||||||||||
Environment
|
Ambient temperature
|
-10℃~+50℃(internal type)
|
|||||||||||||||
Ambient humidity
|
Below 90%RH (non-condensing)
|
||||||||||||||||
Vibration
|
9.8 m/s2 (1G) at a vibration frequency below 20 Hz, 2 m/s2 (0.2G) at a vibration frequency above20 Hz
|
||||||||||||||||
Applicable places
|
Indoor (Protected from corrosive gasses and dust)
|
||||||||||||||||
Storage temperature
|
Payment Terms: | T/T |
---|---|