Model: | - |
---|---|
Brand: | - |
Origin: | - |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | Harmonic protector , Filter compensation , Low-voltage complete |
Price: |
-
|
Min. Order: | - |
Last Online:21 Jun, 2021 |
1) product features:stable voltage, ensure the power quality is qualified,dynamic reactive power compensation, and improve the power factor, filter harmonic current, reduce the temperature of the equipment, improve the service life of the equipment, to improve power factor, save electricity, to avoid a fine, to improve capacity utilization, increase the load capacity,
2) product features:The complete set of low-voltage dynamic reactive power compensation filtering device with double function characteristics of TSC and power filter, is a kind of advanced and unique thyristor flexible cutting technology. all filter group was achieved by controlled thyristor contactless automatic cutting, to adopt advanced technology for thyristor flexible cutting (FACTF) and special process design of the filter, to avoid the traditional contactor cut and thyristor zero shots cut when the flow, the transient impact, without discharge to pitch. Extend the service life of the dynamic compensation system. group controlled by the controller for filter, improve the fast response ability of the filter bank, according to the load case of the electric distribution system dynamic frequency of cutting. The dynamic response time is not more than 20 ms. powerful and easy to debug LCD controller, can be real-time display system voltage, power factor, input filter on the number of groups, such as offset current data. Can, over voltage value of power factor, loss of pressure value, flow value, harmonic distortion rate, cast time delay parameters such as cutting programming. Have over-voltage, over-current, owe flow, equipment, such as temperature 60 ℃ alarm function.according to the balance of three phase load and asymmetry load can realize three-phase or cut points of a companion, system designed according to the customer, filtering effect is obvious, power factor not less than 0.93 after expiation of complete sets of low-voltage dynamic reactive power compensation filtering device adopted by the thyristor cutting power filter the application of this new technology, for the power distribution system provides a dynamic compensation to improve the power factor, filtering harmonic and improve power quality, stable voltage loss reduction and energy saving of the new method.
3) the product scope of application:The device is widely used in electric power, steel, coal, railway, petroleum, machinery, chemical industry, light industry, building materials, mining, shipbuilding, ports and other low voltage 380 v, 660 v, 380 v power supply and distribution system, the requirements of dynamic reactive power compensation and harmonic inhibition or governance, especially suitable for rolling mill, electric welding machine, crane, elevator, such as driving a harmonic, reactive load and high and volatile.
4) technical parameters:project,parameter
The rated voltage
400V、660V、1000
400 v, 660 v, 1000
The dynamic response time
<20ms
< 20 ms
For seriesLevel 3 ~ 23
The environment temperature
-25°C~45°C
- 25 ° C ~ 45 ° c.
Measure the voltage rating
400V/100V
400 v / 100 v
Measure the current rating
5A
5 a
Harmonic measurement range
1-25 times harmonic
precisionCurrent, voltage magnitude of 0.5
power 1.5 on the Richter scale are unlikely
The fundamental wave reactive power compensation
The power factor above 0.9 ~ 0.95
The machine power consumption
0.6% or less device capacity
Relative humidity
<85%
< 85%
The atmospheric pressure
From 80 to 110 kpa
The altitude
≤2000m
2000 m or less
Installation site should be without severe mechanical vibration and electrical conductivity or explosive dust, no strong electric field or magnetic field, no damage to the insulating and clothing metal harmful gas and steam, is not subject to direct sunlight, rain and snow and severe fungal attacks; Installation tilt is not more than 50.