Model
|
DTM-362, DTM-352, DTM-332
|
Telescope
|
Tube Length
|
158mm/6.22 in.
|
Magnification
|
33x (21x/41x with optional eyepieces)
|
Effective diameter of objective
|
45mm/1.77 in. (EDM: 50mm/1.97 in.)
|
Field of view
|
1°20’
|
Resolving power
|
2.5”
|
Minimum focusing distance
|
1.3m/4.26 ft.
|
Distance measurement
|
Range with Nikon specified prisms
|
|
Normal conditions
|
(Ordinary haze, visibility approx. 20km/12.5 miles)
|
With reflector sheet
(5 x 5cm)
|
5 to 100m (16.4 to 328 ft.)
|
With mini prism
|
1,000m/3,280 ft.
|
With single prism
|
2,000m/6,560 ft
|
With triple prism
|
2,600m/8,530 ft.
|
Good conditions
|
(No haze, visibility of over 40km/25 miles)
|
With reflector sheet
(5 x 5cm)
|
5 to 100m (16.4 to 328 ft.)
|
With mini prism
|
1,200m/3,930 ft.
|
With single prism
|
2,300m/7.540 ft.
|
With triple prism
|
3,000m/9,840 ft.
|
Accuracy (Prism/Precise mode)
|
±(3+2ppm x D)mm
±(3+3ppm x D)mm (–20°C to –10°C, +40°C to +50°C
|
Measuring interval*1
|
|
Precise mode
|
1.6 sec. (initial 1.6 sec.)
|
Normal mode
|
1.0 sec. (initial 1.4 sec.)
|
Least count
|
|
Precise mode
|
1mm/0.002 ft.
|
Normal mode
|
10mm/0.02 ft.
|
Ambient temperature
range*2
|
–20°C to 50°C/–4°F to +122°F
|
Atmospheric correction
|
|
Temperature range
|
–40°C to 60°C/–40°F to +140°F
|
Barometric pressure
|
400 to 999mmHg/533 to 1,332hPa/15.8 to 39.3 in.Hg
|
Prism offset
|
–999 to 999
|
Angle measurement
|
|
Reading system
|
Photoelectric detection by incremental encoder
|
Horizontal angle
|
Diametrical(DTM-362/352), Single(DTM-332)
|
Vertical angle
|
Single
|
Minimum increment
(Degree, Gon, MIL6400)
|
Degree: 1/5/10”, Gon: 0.2/1/2mgon, MIL6400: 0.005/0.02/0,05mil
|
DIN 18723 accuracy
(horizontal and vertical)
|
5”/1.5mgon (3”/1.0mgon:DTM-362)
|
Tilt sensor
|
|
Type
|
Dual-axis(DTM-362/352), Single-axis(DTM-332)
|
Method
|
Liquid-electric detection
|
Compensation range
|
±3'
|
Setting accuracy
|
1"
|
Level vial
|
|
Plate level vial
|
30"/2mm
|
Circular level vial
|
10'/2mm
|
Optical plummet
|
|
Magnification
|
3x
|
Focusing range
|
0.5m/1.6 ft. to ∞
|
Display
|
Graphic LCD (128 x 64 dot)
Both sides(DTM-362/352), Single side(DTM-332)
|
Point memory
|
10,000 records
|
Dimensions (W x D x H)
|
168 x 173 x 335mm/6.6 x 6.8 x 13.2 in.
|
Weight (approx.)
|
|
Main unit (with battery)
|
5.3kg/11.7 lbs.(DTM-362/352),
5.2kg/11.5 lbs.(DTM-332)
|
Battery
|
0.4kg/0.9 lbs
|
Carrying case
|
2.4kg/5.3 lbs
|
On-board Ni-MH battery
BC-65
|
|
Operation time
|
|
Continuous distance/angle
measurement
|
Approx. 16 hours*3
|
Distance/angle
measurement every 30 seconds
|
Approx. 27 hours
|
Angle measurement
|
Approx. 30 hours
|
Battery charger for BC-80/65
|
Approx. 2.0 hours for full recharge
|
Quick charger Q-70C (12V DC cigarette lighter charger)
|
Approx. 2.0 hours (fully discharged BC-65 requires more than one charge)
|