Model: | E71T-1 |
---|---|
Brand: | tianshen |
Origin: | Made In China |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | welding wire , E71T-1 , E71T-GS |
Price: |
US $1450
/ ton
|
Min. Order: | 10 ton |
Last Online:16 Jan, 2013 |
We specialize in producing flux cored wire, our R&D center works closely with the professional experts and professors from different universitis and national research institutes. Our manufacture facility owns the advanced production equipment, up -to-dated inspection/measurement instrument and the perfect evaluation and quality control systems, we have ISO 9001:2000 certificate.We have 18 production lines with the capacity of 50,000tons per year. Our E71T-1 FCW performs very low spattering, high effective vertical welding, very stable arc and fast welding rate. The diffusible hydrogen content in the deposited metal reaches 3.5ml/100g, which significant avoid the cold cracking and porosity. We are the only FCW supplier in China has 3YH5 certification.
--Specification conformance
AWS A5.20 E71T-1/ JIS Z3313 YFW C50DR
--Description
YC-YJ502(Q) is a gas-shielded carbon steel wire for fabrication of mild and low carbon steel, steel-structure construction ,bridge-building and pressure vessel grades. This all position wire provides good welding performance with 100% CO2. It provides consistent chemistry, steady arc, low spatter and an excellent bead appearance.
--Shielding gas
100% CO2
--Chemical Composition of deposited metal (%)
Item |
C |
Mn |
Si |
P |
S |
Cr |
Ni |
Mo |
V |
Cu |
Standard |
≤0.18 |
≤1.75 |
≤0.90 |
≤0.03 |
≤0.03 |
≤0.20 |
≤0.50 |
≤0.30 |
≤0.08 |
≤0.35 |
--Mechanical Properties Of Deposited Metal
Item |
Yield Point (MPa) |
TensileStrength (MPa) |
Elongation (%) |
Charpy V-notch Impact Toughness |
||
Test Temp. (°C) |
Impact Energy (J) |
Average (J) |
||||
Standard |
≥400 |
≥480 |
≥20 |
-20 |
≥27 |
--Recommended Current (DC+) and Voltage Range
Welding position |
Dia. 1.2 mm |
Dia.1.6 mm |
||||
CurrentRange |
VoltageRange |
CO2 Flow |
CurrentRange |
VoltageRange |
CO2 Flow |
|
Flat |
120~320A |
16~34V |
15~25 L/Min |
180~400A |
22~42V |
15~25 L/Min |
Horizontal |
120~280A |
16~29V |
15~25 L/Min |
180~400A |
22~42V |
15~25 L/Min |
Overhead |
120~240A |
16~28V |
15~25 L/Min |
|||
Vertical Up |
120~240A |
16~27V |
15~25 L/Min |
180~260A |
23~30V |
15~25 L/Min |
Vertical Down |
120~260A |
16~29V |
15~25 L/Min |
180~260A |
23~30V |
15~25 L/Min |
Procedures may vary with change in position, base metals, filler metals,equipment and other changes.
Packing:Precision layer winding, wrapped with volatile corrosion inhibitor paper, vaccum
packed with aluminium foilbags, further packed in seaworthy corrugated carton.
Payment Terms: | TT |
---|---|