TC-600 Series OTDR developed by TECHTX, which meet the needs on the wide range of measurement by FTTX, Metropolitan Area Network, Backbone Network and other optical networks.
TC-600 OTDR Technical Specifications
Technical Specifications:
Wavelength (nm)850/13001310/15501310/1490/15501625
Dynamic range (dB)223/2132/3034/3236/3438/3634/32/3238/36/36304325344365
Pulse width (ns)5, 20, 40, 80, 160, 320, 640, 12805, 20, 40, 80, 160, 320, 640, 1280, 2560, 5120, 10240, 20480
Event blind zone (m)32m2m
Attenuation blind zone (m)39m9m
Linearity (dB/dB)± 0.05 dB/ dB
Loss threshold (dB)0.05
Loss resolution ratio (dB)0.01
Sampling resolution ratio (m)0.125 to 8
Sampling point32K
Distance uncertainty (m)± (1 m + 5× 10-5× Distance + sampling interval)
Distance scope (km)0.3 to180
Typical real-time refreshing duration (s)0.2
Memory capacity of traceSD Card (2G), > 10000 pieces
Duration of measurementDefined by user; 5sec, 10sec, 15sec, 30sec, 1min, 2min, and 3min are selectable
General specification Interface category
Dimension (H× W× D)150× 235× 66
Optical interfaceFC/UPC (PC, and APC are selectable)
Weight1.5kg
Data interface USB interface, SD card interface
TemperatureRunning temperature -10 to 50
Memory temperature -40 to 70
Visible failure orientation VFL
Relative humidity 0% to 95% (non condensation) Wavelength650nm
Power supply Lithium battery; Continuing working duration ≥ 8 hours Output power (dBm)≥ -3
Warranty period12 months Maximum testing distance3km
Remarks:
1. The technical specification describes the ensured performance of the instrument when using typical PC model connector to measure. Without considering the uncertainty caused by optical fiber refractivity.
2. Dynamic range is the data measured under the condition of the maximum pulse width and 3 minutes of average time. Dynamic range is the data measured under the condition of 180km/20480ns/3min.
3. Measuring conditions of blind zone: Reflection event is within 4Km, reflection strength < -35dB. Measured by the minimum pulse width.
4. Dynamic range measured when there is filter.
5. Dynamic range measured when there is no filter.
contact online: skype: wztechtc icq: 698554292
Payment Terms: | TT/LC/DP/DA |
| |
Product Image
Img 1
Img 2
Img 3
Img 4
Img 5
Send Inquiry to this Member
Related Products of this Company
This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please
click here.
China Suppliers Quick Searching:
,