Model: | SDT-8KW |
---|---|
Brand: | SANDI |
Origin: | Made In China |
Category: | Electronics & Electricity / Power Supply & Distribution / Other Power Supply & Distribution |
Label: | phase converter , power converter , 8kw converter |
Price: |
US $1
/ pc
|
Min. Order: | 1 pc |
Last Online:19 Dec, 2024 |
8000W phase converter single phase to three phase inverter
SANDI SDT series single-phase to three-phase converter, adopted SVPWM modulation control technology, which can convert ordinary single-phase power to industrial three-phase power. After through SDT series single-phase to three phase converter power conversion, the three-phase power output is standard pure sine wave, the harmonic distortion rate (THD) is less than 2%, totally meet the national standards of three-phase power quality, applicable to all types of load.
The SDT series single-phase to three-phase converter can solve production inconvenience because of some areas with the three-phase electric power restrictions, also solved some user requirements that can’t apply for the three-phase electric because of space limitation.
Technical Features:
1) Using the fifth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It’s service life can up to 15 years or more.
2) Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter’s usage, which reduced the cost of equipment investment, easy to connect wires and control.
3) Pure sine wave output with good transient response less than 50ms, waveform distortion is very little, higher conversion efficiency and stable output voltage.
4) Adopted low frequency transformer which ensure the input voltage and output voltage are completely electrical isolated to avoid interference.
5) Using SVPWM space vector algorithms, high conversion efficiency, high instantaneous power and low losses conversion efficiency up to 94%.
6) Output AC Power is suitable for all types of electric appliances, electric tools, electric motors etc. higher capability of driving load.
7) Converter has the function of filtering the grid disturbance and interference at the same time, which is a good performance of stabilized voltage and frequency power, to provide a more stable and pure power supply environment for the backend devices.
8) Output perfect protection function, with output over-voltage, overload, short circuit, over temperature, self-diagnosis protection and other protection.
9) High conversion efficiency, high instantaneous power and low load loss.
10) The input voltage, output voltage, frequency and phase can be custom made.
Technical Data
Model |
SDT-8KW |
|
Isolation mode |
Low Frequency Transformer |
|
AC Input |
Input rated voltage (Vac) |
Single phase 220V |
Input rated voltage range |
110/120/220/230/240Vac optional |
|
Input rated current(A) |
36A |
|
AC Output |
Rated output power |
8KW |
Output waveform |
Pure sine wave |
|
Phases |
Three phase, 4 wire |
|
Output rated voltage |
380VAC ±3% |
|
Output voltage range |
220/380/400/415/440/480Vac optional |
|
Output rated current |
12A (phase current) |
|
Output Frequency |
50Hz/60Hz±0.05Hz |
|
Power Factor(PF) |
0.99 |
|
Overload Ability |
150%, 10s |
|
Efficiency |
>94% |
|
Waveform distortion rate (THD) |
<3%(Linear load) |
|
Dynamic Response (0 to 100% load) |
5%,≤50ms |
|
Display |
LCD+LED |
|
Running mode |
Working continuously |
|
Electrical insulation properties |
2000Vac, 1 Minute |
|
Protection function |
Protection |
Input under voltage, over voltage, output over-current, short circuit, overheating etc. |
Cooling method |
Fan-cooled |
|
Short-circuit protection |
No automatic recovery, need to restart the machine |
|
Working environment |
Ambient temperature |
-15~+55℃ |
Using environment humidity |
0~90%,No condensation |
|
Noise ( 1 meter) |
≤50dB |
|
Degree of protection |
IP20(indoor) |
|
Using altitude(m) |
≤3000 |
|
Dimension (mm) |
540x540x760mm |
|
CE Standard |
EN60950-1:2006+A11:2009, EN61000-6-4:2007+A1:2001, EN61000-6-2:2005, EN61000-3-12:2005, EN61000-3-11:2000 |