Model: | - |
---|---|
Brand: | - |
Origin: | - |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | gas detector , gas detection , gas analyser |
Price: |
-
|
Min. Order: | - |
Last Online:07 Jan, 2014 |
GRI-8523 Wall-mounted VOC Detective Alarm
Product Introduction :
GRI-8523 series single point wall-mounted VOC detective alarm is an apparatus which can continuously detect various volatile gas (VOC) and the gas concentration of lonization potentials ≤10.6eV in operate environment .
The VOC detective alarm is natural diffused gas detective way, adopt America Baseline-MOCON imported PID photoionization as the sensitive component, with high sensitivity and excellent repeatability; Highlight LED backlit plus LCD display screen real-time display the concentration of leakage gas ,Exceed pre-set alarm point immediately start sound and light signals and replay control signals; international standard 4-20mA signal can directly connect DCS system of factory ,connect RS485 digital signal and factory PC .
Product Feature:
Imported NDIR infrared module ,performance stable and reliable ;
Provide LCD display and sound and light alarm , Full-featured;
Intelligent design , zero , alarm setting ,calibration is very convenient ;
Two alarm replays can output control signal for use to drive fans and other equipment;
Apparatus DC9-24V wide range power supply (use power adapter can connect AC 220V),can be use once connect the power supply ;
Metal shell, robust and reliable ;
Infrared remote control ,more convenient for setting ,modifying the parameters of apparatus;
Have standard 4-20mA current signal and RS485 digital signal output;
Application:
Personal safety protection of dangerous places, environmental protection monitoring, industrial safety monitoring, detection of dangerous substances.
Technical parameter :
Product name Single point wall-mounted VOC detective alarm
Sensor name Photoionization sensor
Product model GRI-8522
Sensor model PID-TECH
Input power supply 9-24VDC
Test object VOCs
Current consumption 50-250mA
Test principle PID(Photoionization)
Display way LCD display screen
Test way Diffused / pipe
Alarm way 2 levels sound and light alarm
Test range 20/2000ppm
Alarm error ≤±5% alarm set value
Accuracy 10.6eV
Operate temperature 0℃-50℃
Resolution 0.01/0.1ppm
Operate humidity 0-95%RH(non-condensing )
Pre-heating time ≤±2%FS
Pressure range Atmosphere pressure ±10%
Response time T90≤20S(Diffused )
Signal output 4-20mA or RS485
Use life >1year
Contact capacity 1A/120VAC or 1A/24VDC
Repeatability ≤±1%FS
Note: above part of sensors parameter please standard as the latest technical manual of PIDsensor.