Model: | HY-PUMP-XX-XX |
---|---|
Brand: | HOYATEK |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Instrument / Other Electronic Instrument |
Label: | Pump Light Source , Wavelength 980nm , 1480nm |
Price: |
US $1000
/ pc
|
Min. Order: | 1 pc |
Last Online:14 Oct, 2016 |
Pump Light Sourceis designed for EDFA (erbium-doped fiber amplifier ), EDFL (Erbium Doped Fiber Laser) & YDFL (Ytterbium Doped Fiber Laser). Pump Light Source output powercan reach 750mW.
Applications:
Specification :
Parameter |
Symbol |
Unit |
Values |
|||||||||||||||||||||||||||||||||||||||
980 PUMP |
1480 PUMP |
|||||||||||||||||||||||||||||||||||||||||
Wavelength |
λ |
nm |
976±2 |
1475±10 |
||||||||||||||||||||||||||||||||||||||
Maximum power output |
Pmax |
mW |
1000 |
700 |
||||||||||||||||||||||||||||||||||||||
Short-term output power stability |
Pss |
dB |
≤±0.05@15 min. |
|||||||||||||||||||||||||||||||||||||||
Long-term output power stability |
PLs |
dB |
≤±0.1@8h. |
|||||||||||||||||||||||||||||||||||||||
Operating temperature |
TOP |
℃ |
module :-20 ~ +60 |
|||||||||||||||||||||||||||||||||||||||
Bench-top :0 ~ +60 |
||||||||||||||||||||||||||||||||||||||||||
Storage temperature |
Ts |
℃ |
-20 ~+70 |
|||||||||||||||||||||||||||||||||||||||
Relative Humidity |
RH |
% |
20~80 |
|||||||||||||||||||||||||||||||||||||||
Dimensions(L×W×H ) |
mm |
Module : 100×70×19 |
||||||||||||||||||||||||||||||||||||||||
Bench-top : 330×220×110 |
||||||||||||||||||||||||||||||||||||||||||
Fiber type |
SMF-28E or PMF |
|||||||||||||||||||||||||||||||||||||||||
Connector type |
Without connector, FC/PC,FC/APC or customizable |
|||||||||||||||||||||||||||||||||||||||||
Alarm signal |
Low level alarm |
|||||||||||||||||||||||||||||||||||||||||
Power |
Module: DC +3.3V~5V; Bench-top: AC 220V±10%,50Hz,20W Ordering information
|
Note:
Stability testing base on the environment temp. of 23±2℃,after pre-heating 15 minute.