Product Description
An overview,
When material is fast particle radiation, the electron gain energy, into the excited state, from low level track transition to high-energy orbit;And when the material from the excited state returned to normal, the electrons from high-energy track back to the low level track, the rest of the energy released in the form of radiation, it is light.
Diamond under X-ray irradiation, glow effect, is the diamond processing industry production, one of the effective method of rapid extraction of diamond.
Dandong glory ray instrument co., LTD. According to the light effect the development, design, production X-ray diamond dressing device, is widely used in diamond dressing.
Second, the conditions of use
1, this equipment is installed in a laboratory or workshop fixed places;
2, the environment temperature;10 ℃ and 40 ℃;
3, environment relative humidity;85% or less.
4, power supply:
A, frequency 50 hz, voltage 220 v, capacity of 5 kw;
B, power supply voltage fluctuation is less than the rated voltage of + / - 10%;
C, has a good grounding device, grounding resistance is not greater than 0.5 Ω.
5, no more than 1000 m altitude, if it is more than 1000 m rated lower should comply with the provisions of the general electric product performance;
6, cooling water, water not less than 3 l/min, the water temperature is not more than 30 ℃;
Three, technical parameters
This equipment adopts high voltage rectifier circuit, X ray tube anode grounding, strong water cooling.
1, the X-ray tube voltage regulating range: 0 to 30 kv continuous adjustable;
2, X-ray tube current adjusting range: 0 to 20 ma continuous adjustable;
3, X-ray radiation field: Φ 100 mm;
4, conveyor belts, adjust speed range: 0-15 m/min continuous adjustable;
5, mA value by more than 10% of the rating, the device automatically cut off the high voltage equipment, and sound and light alarm;
6 KV value by more than 5% of the rating, the device automatically cut off the high voltage equipment, and sound and light alarm;
7, cooling water flow rate (export) less than 3 l/min, the device automatically cut off the high voltage equipment, and sound and light alarm;