Model: | MQW-50A |
---|---|
Brand: | Blue Design |
Origin: | Made In China |
Category: | Transportation / Car Accessories / Auto Repair Tools |
Label: | Exhaust Gas Analyzer , gas detector , analyzer |
Price: |
US $3900
/ pc
|
Min. Order: | 1 pc |
Last Online:26 Mar, 2015 |
1.Environmental Conditions:
Temperature: 0°C ~ 40°C
Relative Humidity: ≤90%
Power supply: AC220V ± 10%,50±1Hz
Atmospheric Pressure: 86.0 kPa ~106.0kPa
2.Measurement Range and Resolution:
Project |
CO |
CO2 |
HC |
O2 |
NO |
Measurement Range |
0.00-15.00 (×10-2) |
0.00-18.00 (×10-2) |
0-9999 (×10-6) |
0-25.00 (×10-2) |
0-5000 (×10-6) |
Resolution |
0.01 (×10-2) |
0.1 (×10-2) |
1 (×10-6) |
0.02 (×10-2) |
1 (×10-6) |
3.Indicating Value Error:
Air type |
Measurement Range |
Allowable error of indicating value |
|
Absolute Error |
Relative Error |
||
HC |
(0~2000)×10-6 |
±4×10-6 |
±3% |
(2001~5000)×10-6 |
---- |
±5% |
|
(5001~9999)×10-6 |
---- |
±10% |
|
CO |
(0.00~10.00)×10-2 |
±0.02×10-2 |
±3% |
(10.01~14.00)×10-2 |
---- |
±5% |
|
CO2 |
(0.0~16.0)×10-2 |
±0.3×10-2 |
±3% |
(16.1~18.0)×10-2 |
---- |
±5% |
|
NO |
(0~4000)×10-6 |
±25×10-6 |
±4% |
(4001~5000)×10-6 |
---- |
±8% |
|
02 |
(0.0~25.0)×10-2 |
±0.1×10-2 |
±5% |
Note:The absolute error and relative error listed in the table to meet one of the requirements to. |
4.Zero point drift and Gauge matrix drift:
The zero drift of the instrument and indication drift should not exceed its Indication error within one hour.
5.Resolution:
The indicating value repetition of repetition equipment should not exceed 1/2 of allowable error of indicating value.
6.Preheating time:
Preheating time of the instrument is not more than 30min.
7.Response time:
HC、CO、CO2≤8s,O2≤12 s,NO≤15s
8.Power Consumption: 300W
9.Weight:15kg
10.Dimensions: 550mm (Length)×485mm(Width)×230mm (Height)
11.Package(Carton):620mm (Length)×580mm(Width)×370mm(Height)
This equipment is used to ignite the engine exhaust measurement, measurement object for the discharge of exhaust HC, CO, CO2, O2, and NO concentration.The technical requirements of the specifications, features, and performance of the equipment meets the GB18285, JJG688 related provisions, the detection accuracy level reached 00. Applicable to a simple transient conditions (Vmas) and steady-state conditions (ASM) system equipment for measurement of HJ/T290, and HJ/T291 condition equipment and technology required to meet the special five gas analysis instruments.
▣ The device uses the non-dispersive infrared absorption principle (NDIR) the use of imported the HORIBA optical platform measuring CO, HC, CO2 concentration; using electrochemical sensors measuring O2, NO concentration.
▣ Standard equipped with temperature and humidity, speed, oil temperature interface measurable environmental temperature and humidity, engine speed and oil temperature.
▣ The device comes standard with RS232 interface, to facilitate detection line networking, data transfer and print statements.
▣ The sampling channel loading filtration system, efficient separation of oil, water and impurities in the exhaust; pipeline back wash technology, automatic cleaning sampling pipes; detection requirements from the sample gas sampling channels into line with the high-precision sampling platform, in order to ensure measurement accuracy and stability.
▣ Built-Vmas 、ASM testing process, the Chinese big screen detection interface to guide users with implementation of on-site detection.
▣ The device can automatically calculate and display the engine air-fuel ratio λ value, providing automatic zeroing, the license plate number of input and time display function, provides a 4000 measurement data storage and access to and license plate number intelligent search function.
▣ Recommendations supporting the use of ML-100, to achieve Vmas detection.
▣ NO detection upgrade for HORIBA NO detection dedicated optical platform.