HRD Onoline Three Phase HF UPS 380/400/415Vac 10-120kVA
1. Perfect Applications:
Internet Servor, Internet Data Center, Medium-scale network system / computing center, bank and securities, business server group, Medium-scale office automation, precision equipment, etc.
2. Complete Digital Control Technology:
Fully digital control with two DSPs, all the subsystems are digital controlled including the IGBT rectifier, inverter, charger, discharger.
3. Excellent electrical properties:
True online double conversion instruction offers the safe and effective power protection for various loads, with strong output load capacity.
4. High input power factor, green and energy-saving:
Input end with PFC and input PF of the whole UPS up to 0.99.
5. Dual AC input source supportable:
Allowable AC and bypass 2 input ac source.
6. Strong environmental adaptability:
Wide input voltage and frequency range, adaptation to all kinds of climatic and geographical environment.
7. Comprehensive protection measures:
Surge Protection, short circuit protection, and other protection to ensure the reliability of UPS. IGBT and SCR adopts the advanced EUPEC power module. The adoption of advanced technology (IGBT driving technology, IGBT soft over-current shutdown) improves the reliability and safety of inverter.
8. Similar modular design:
Each phase main board are designed like rack for easy assembling and maintenance, inbuilt battery pack plug-in design for easy use.
9. Intelligent battery management (ABM):
Adopting the intelligent battery management. Intelligent interval three-stage charging process( constant current,constant voltage, float charging and charger shut off, when battery voltage decrease to a lower level, charger restarts to work). Automatic temperature compensation,( -0.11% per °C ), to extremely extend battery life by 30% and minimize the maintaining work.
Online detecting battery status, the max battery charging current can set by end users according to the battery features, to avoid any damage caused by the big charging current; Back up time displayed on the LCD screen. Periodic self-test battery, detecting the battery problems timely. With battery inverse connection, over voltage / current protection, to protect the battery.
10. Superior network monitoring capabilities
Communication port (RS232, USB, and so on) connecting with computer, SNMP card optional.
11. Easy-maintenance design:
a) Adopts the full front maintenance design, reducing the restrictions on the installation space, and saving the space of computing center;
b) Modular design class, convenient and easy site maintenance;
c) With manual maintain bypass;
d) Battery replacement without disrupting the UPS running;
e) Historical records search function, events up to1,000 items.
12. Friendly interface with Large LCD with multi language display (7 languages)
Large LCD display and LED statu s indication; Abundant information display of UPS English, Spanish, Portugese, Russion.
Model |
PW3310 |
PW3315 |
PW3320 |
PW3330 |
PW3340 |
||||||||
Rating Power |
10kVA/9kW |
15kVA/13.5kW |
20kVA/18kW |
30kVA/27kW |
40kVA/36kW |
||||||||
AC Input |
|||||||||||||
Rated voltage |
380/400/415Vac(Line-Line) |
||||||||||||
Input connection |
3phase +N+PE |
||||||||||||
Power factor |
Above 0.999 |
||||||||||||
THDi |
Less 2% |
||||||||||||
Voltage range |
-40%~+25% |
||||||||||||
Frequency |
40-70Hz |
||||||||||||
Bypass |
+/- 15%(settable) |
||||||||||||
Output |
|||||||||||||
Power factor |
0.9 (lag) |
||||||||||||
voltage precision |
380/400/415Vac±0.5% |
||||||||||||
Dynamical voltage transient |
Less 5% ( 0~100% load step) |
||||||||||||
THDU |
THD less 0.6%( linear load ),3%(non-linear load) |
||||||||||||
Crest Factor |
3:1 |
||||||||||||
Frequency tracking range |
50/60Hz±3Hz |
||||||||||||
Output Frequency precision |
±0.05%(Battery mode) , ±3hz(Line mode) |
||||||||||||
phase displacement |
120±0.5°(Balance or imbalance load ) |
||||||||||||
Voltage unbalance |
+/-3%( 100% unbalance load) |
||||||||||||
Frequency tracking rate |
Less 1Hz/s |
||||||||||||
Overload capability |
110%: 1hour, 110%<Load<125%, transfer to bypass after 10 minutes |
||||||||||||
125%<Load<150%, transfer to bypass after 1mins; above 150%, transfer to bypass after 200ms |
|||||||||||||
Bypass overload |
Below125% long time operation 125%<Load<150%,10mins;above 150% 1S |
||||||||||||
System |
|||||||||||||
System efficiency |
Above 92%(Line and battery mode) |
||||||||||||
98%(ECO mode) |
|||||||||||||
Display |
Touch screen LCD+LED |
||||||||||||
EMC |
IEC62040-2 |
||||||||||||
IEC61000-4-2 (ESD) |
|||||||||||||
IEC61000-4-3 (RS) |
|||||||||||||
IEC6100-4-4 (EFT) |
|||||||||||||
IEC6100-4-5 (Surge) |
|||||||||||||
Noise (1m) |
50- 60dB |
||||||||||||
Insulating resistance |
Above 2M (500VDC) |
||||||||||||
Insulating intensity |
(input, output to PE) 2820Vdc, leakage current lower than 3.5mA, no flashover in 1min |
||||||||||||
Surge protection |
Meet the requirement of IEC60664-1class,endure surge of 1.2/50us+8/20us higher than 6KV/3KA |
||||||||||||
IP class |
IP20 |
||||||||||||
Battery configuration |
|||||||||||||
Installation(dc) |
+/-216Vdc( 168/192/216/240Vdc settable from LCD screen) |
||||||||||||
Battery type |
Free Maintenance Lead Acid (Gel battery or Ni-Cd) |
||||||||||||
Long run |
Battery to be connected external |
||||||||||||
Inbuilt battery |
36pcs *7ah |
36pcs *7ah |
36pcs *9ah |
72PCS*7ah |
72pcs*9ah |
||||||||
Connection |
Bottom cable connection in front |
||||||||||||
Charger |
1-15A,ABM technology (settable from LCD) |
||||||||||||
Physical |
|||||||||||||
Unit Dimension (Long-run) |
390*850*977MM (W*D*H) |
500×717×1150 MM (W*D*H) |
|||||||||||
Unit Dimension (Inbuilt batt.) |
390*850*977MM (W*D*H) |
500×717×1550 MM (W*D*H) |
|||||||||||
Weight (KG) (Long -run) |
110/130 |
130/150 |
152/172 |
160/190 |
160/190 |
||||||||
Weight (KG) (Inbuilt Batt.) |
182/202 |
202/222 |
216/236 |
331/361 |
367/397 |
||||||||
10kva and 15kva:inbuilt 36pcs 7ah 20kva: inbuilt 36pcs 9ah |
(72pcs 7ah) |
(72pcs 9ah) |
Model |
PW3360 |
PW3380 |
PW33100 |
PW33120 |
|||
Rating Power |
60kVA/54kW |
80kVA/72kW |
100kVA/90kW |
120kVA/108kW |
|||
AC Input |
|||||||
Rated voltage |
380/400/415Vac(Line-Line) |
||||||
Input connection |
3phase +N+PE |
||||||
Power factor |
Above 0.999 |
||||||
THDi |
Less 2% |
||||||
Voltage range |
-40%~+25% |
||||||
Frequency |
40-70Hz |
||||||
Bypass |
+/- 15%(settable) |
||||||
Output |
|||||||
Power factor |
0.9 (lag) |
||||||
voltage precision |
380/400/415Vac±0.5% |
||||||
Dynamical voltage transient |
Less 5% ( 0~100% load step) |
||||||
THDU |
THD less 0.6%( linear load ),3%(non-linear load) |
||||||
Crest Factor |
3:1 |
||||||
Frequency tracking range |
50/60Hz±3Hz |
||||||
Output Frequency precision |
±0.05%(Battery mode) , ±3hz(Line mode) |
||||||
phase displacement |
120±0.5°(Balance or imbalance load ) |
||||||
Voltage unbalance |
+/-3%( 100% unbalance load) |
||||||
Frequency tracking rate |
Less 1Hz/s |
||||||
Overload capability |
110%: 1hour, 110%<Load<125%, transfer to bypass after 10 minutes |
||||||
125%<Load<150%, transfer to bypass after 1mins; above 150%, transfer to bypass after 200ms |
|||||||
Bypass overload |
Below125% long time operation 125%<Load<150%,10mins;above 150% 1S |
||||||
System |
|||||||
System efficiency |
Above 94%(Line and battery mode) |
||||||
98%(ECO mode) |
|||||||
Display |
Touch screen LCD+LED |
||||||
EMC |
IEC62040-2 |
||||||
IEC61000-4-2 (ESD) |
|||||||
IEC61000-4-3 (RS) |
|||||||
IEC6100-4-4 (EFT) |
|||||||
IEC6100-4-5 (Surge) |
|||||||
Noise (1m) |
50- 60dB |
||||||
Insulating resistance |
Above 2M (500VDC) |
||||||
Insulating intensity |
(input, output to PE) 2820Vdc, leakage current lower than 3.5mA, no flashover in 1min |
||||||
Surge protection |
Meet the requirement of IEC60664-1class,endure surge of 1.2/50us+8/20us higher than 6KV/3KA |
||||||
IP class |
IP20 |
||||||
Battery configuration |
|||||||
Installation(dc) |
+/-216Vdc( +/-168/192/216/240Vdc ,settable from LCD screen) |
||||||
Battery type |
Free Maintenance Lead Acid (Gel battery or Ni-Cd) |
||||||
Connection |
Bottom cable connection in front |
||||||
Charger |
10-40A( settable from LCD screen) |
||||||
Physical |
|||||||
Unit Dimension (UPS) |
600×850×1680 MM (W*D*H) |
735×850×1680 MM (W*D*H) |
|||||
Unit Dimension (Packing) |
954×704×1857 MM (W*D*H) |
954×839×1857 MM (W*D*H) |
|||||
Weight N/G (KG) |
240/280 |
260/300 |
320/360 |
340/380 |
Packaging & Shipping
Our Services
FAQ
What is the difference between high frequency UPS and low frequency UPS?
Item |
High frequency UPS |
Low frequency UPS |
Input PF |
0.99 |
0.7 |
Efficiency |
85-90% |
75-85% |
Power density |
Higher |
Lower |
Power device capacity |
Less |
More |
Weight |
Light |
Heavy |
Dimension |
Compact |
Bigger |
Price |
Lower |
Higher |
Overload ability |
Normal |
Better |
Anti input sugar capacity |
Normal |
Better |
Output anti-crush , short circuit capacity |
Normal |
Better |
N-G voltage |
Bad |
Better |
Output component |
More |
Less |
Damage extent of device when it’s fail |
Higher |
Lower |
Stability |
Normal |
Better |
Certifications
Company Information
Trade Shows
2014 GITEX
After-Sales Service
HRD high qualtiy UPS successfully installed
for the National Grand Theatre of Algeria