Model: | EWD-H-XP1 |
---|---|
Brand: | EST |
Origin: | Made In China |
Category: | Construction & Decoration / Building Establishment |
Label: | elevator parts , elevator load cell , overload sensor |
Price: |
US $15
/ pc
|
Min. Order: | 10 pc |
Last Online:15 Jul, 2015 |
EWD-H-XP1 Elevator load weighting device .elevator parts load cell
How to install elevator load sensor?
Type EWD-H-XP1 Elevator Load Weighing Device
INTRODTION MANUAL
● This system is applicable to all elevators with movable car platform and energy-saving operation escalator in need of overload signals. This device is of extremely high performance-price ratio. This appliance is to overcome the inherent disadvantage of the mechanical overload switch and to replace it.
1. Working in a contact less and inductive way. No mechanical movement itself. Being directly installed in the original place of overload switch. No necessity of changing the mechanism of elevator car.
2. Adopting strong inductive magnet, improving the anti-interference of the system to the utmost.
⒈ |
Application Range |
Applicable to all elevators with movable car platform in need of overload signal with a inspection clearance of 8~15㎜. |
2 |
Sensitivity |
Overload turning point≤Rated load adjusting point±0.05㎜ |
3 |
System Error |
≤1.5% (5~40℃) |
4 |
Output Mode |
1 pair of relay dynamic CLOSE or dynamic OPEN contacts respectively with the capacity of DC/AC 48V/500mA. |
5 |
Operation Ambient Temperature |
-25~55℃ |
6 |
Power Supply |
AC/DC 24V(±10%)/15mA. The operating current of the whole machine≤100 mA. |
7 |
Install Position |
Movable elevator car platform |
8 |
Overall Size |
Column of Φ24×83 mm |
This system weighs the elevator car load based on the principle of the elastic deformation of movable elevator car platform caused by loading with the HALL sensor measuring the change of displacement, fulfilling the aim of load weighing.
Wire |
Function |
Explanation |
Red, black(gray) |
Sys Operating Power |
Operating Power AC/DC24V(±10%)/100mA |
Yellow, White |
Overloading relay dynamic Close contact |
Contact Capacity: DC/AC 48V/500mA |
Blue, green |
Overloading relay dynamic Open contact |
Output wire of this device must not be connected with externalpower supply to avoid everlasting damage.
Accessory: Inductive magnet [20×20×4mm3]1piece
Fastening Nut: 2 sets
If there is any abnormality during adjustment or operation, contact our company directly.
Payment Terms: | TT,Paypal,Western Union |
---|---|