Model: | IP5K |
---|---|
Brand: | Hybridon |
Origin: | Made In China |
Category: | Electronics & Electricity / Power Supply & Distribution / Other Power Supply & Distribution |
Label: | inverter 5000W |
Price: |
US $450
/ unit
|
Min. Order: | 1 unit |
Last Online:17 Oct, 2015 |
DC to AC 24V 220V 5000W Offgrid Power Inverter
Detailed Information
Specifications:
Model | IP1K | IP1.5K | IP2K | IP3K | IP4K | IP5K | IP6K |
Rated Output Power (W) | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 |
Line Mode Specifications | |||||||
Input Voltage | 230Vac(120VAC selectable) | ||||||
Input Frequency | 50Hz/60Hz (Auto detection) | ||||||
Output Voltage Waveform | Pure sine wave | ||||||
Over-Load Protection(SMPSload) | Circuit breaker | ||||||
Output Short Circuit Protection | Circuit breaker | ||||||
Efficiency (Line Mode) | >95% | ||||||
Auto Transfer Relay | 30A | 40A | |||||
Transfer Time | 10ms (typical) | ||||||
Pass through without Battery | Yes | ||||||
Max Bypass Overload Current | 30A | ||||||
Invert Mode Specifications | |||||||
Output Voltage Waveform | Pure sine wave | ||||||
Power Factor | 1 | ||||||
Output Voltage (V) | 230Vac/120 ±10% | 230Vac±10% | |||||
Output Frequency (Hz) | 50/60Hz ± 0.3Hz | ||||||
Auto Tracking Main Frequency (Hz) | 50Hz @ 48-54Hz; 60Hz @ 58-64Hz | ||||||
Output Voltage Regulation | ± 10% rms | ||||||
Efficiency | > 80% | ||||||
Over-Load Protection(SMPSload) | (110% (125% Loa t;150% ±10%; Fault (shutdown output) after 20s | ||||||
Surge Rating | 3000VA | 4500VA | 6000VA | 9000VA | 12000VA | 15000VA | 18000 VA |
Capable Of Starting Electric Motor | 1 HP | 2 HP | 3 HP | ||||
Inverter Breaker Size | 10A | 30A | 40A | ||||
DC Input Voltage | 12V/24V | 12V/24V | 12V/24V | 12V/24V/48V | 24V/48V | 24V/48V | 24V/48V |
Min DC Start Voltage | 11V/22V/43V | ||||||
Low Battery Alarm | 10.5Vdc ± 0.3Vdc for 12V battery;
21.0Vdc ± 0.6Vdc for 24V battery; 42.0Vdc ± 0.6Vdc for 48V battery |
||||||
Low DC input Shut-down | 10.0Vdc ± 0.3Vdc for 12V battery;
20.0vdc± 0.6Vdc for 24V battery; 40.0Vdc± 0.6Vdc for 48V battery |
||||||
High DC input Alarm & Fault | 16Vdc ± 0.3Vdc for 12V battery;
32Vdc ± 0.6Vdc for 24V battery; 64Vdc ± 0.6Vdc for 48V battery |
||||||
High DC input Recovery | 15.5Vdc ± 0.3Vdc for 12V battery;
31.0Vdc ± 0.6Vdc for 24V battery; 62.0Vdc ± 0.6Vdc for 48V battery |
||||||
Power saver | Load ≤25W | ||||||
Charge Mode Specifications | |||||||
Input Voltage | 230Vac / 1200Vac | ||||||
Input Voltage Range | 155-265Vac / 96-127Vac | ||||||
Output Voltage | Same as input voltage | ||||||
Multi Stage Smart Charger (Amp) | 35A/20A | 65A | 65A/40A | 65A/45A/25A | 65A/35A | 65A/40A | 65A/50A |
Charge Current Adjustable Gear | 25%, 50%, 75%, 100% | ||||||
Charger Short Circuit Protection | Circuit breaker | ||||||
Over Charge Protection | Bat. V ≥ 15.7Vdc/31.4Vdc/62.8Vdc, beeps 0.5s every 1s & fault after 60s | ||||||
General Specifications | |||||||
Safety Certification | CE, Soncap, ISO9001 | ||||||
Operating Temperature Range | 0°C to 40°C | ||||||
Storage temperature | 15°C below zero to 60°C | ||||||
Operation humidity | 5% to 95% | ||||||
Audible Noise | 60dB max | ||||||
Cooling | Forced air, variable speed fan | ||||||
Net Weight (KG) | 16 | 21 | 24 | 35 | 44 | 45 | |
Gross Weight (KG) | 19 | 24 | 28 | 39.2 | 48 | 49 | |
Inverter Size | 1000W/1500W/2000W/3000W: 423X185X160MM
4000W/5000W/6000W: 600X185X155MM |
||||||
Carton Box Size | 1000W/1500W/2000W/3000W: 570*315*300MM
4000W/5000W/6000W: 755*319*288MM |
||||||
Wooden Case Size | 1000W/1500W/2000W/3000W: 614X362X359MM
4000W/5000W/6000W: 799X362X359MM |