60w (CE certificate) USA RF Tube CO2 Fractional laser vaginal tightening/ Fractional CO2 laser
I.Treatment Theory:
1. VRL system
Use an articulate arm probe with automatically 3600 rotation technology, producing in 50-70oC at a controlled depth inside the vaginal mucosa - stimulates collagen contraction, restructuring and regeneration; promotes collagen fiber proliferating, remodeling; improves vaginal mucosa microcirculation; increases cell secretion and dynamic reaction function; corrects PH value of vaginal inside; improves the inside environment; achieve female private parts to significant lasting firming, nourishing and restoring harmonious sexual life.
2. Fractional system
Fractional ablative CO2 resurfacing delivers 10600nm laser in fractional manner into the skin while leaving the untreated surrounding areas intact. Laser creates microscopic thermal dot on surface and performs within tissues, offering improve skin tightening, age spots, fine lines, acne scars, stretch marks removal and vulva rejuvenation. The untreated tissue helps to accelerate the healing process and rejuvenate the skin by promoting microcirculation and new cell genesis.
II.Multi-function:
The machine has 3 systems: Fractional CO2, VRL and CO2, can satisfy all needs, very excellent investment Safe treatment: Totally safe, and tested by hundreds of women in the world; the ideal wavelength is absorbed by the mucous membrane micron, to avoid any thermal damage by deep tissue or organ Fast treatment: Each treatment less than 30 minutes and 1-3 times treatment can completely solve the vaginal problems Effective treatment: Effective for all women who have the loosen vaginal; and effective prevention of gynecological inflammation Painless treatment: The patients only can feel warm/hot inside, cannot feel any pain
Treatment of fractional CO2 laser
Perfect skin\whitening\wrinkle removal\ acne prevention\facial beauty\ for human tissue burning\vaporization and coagulation. Mainly used for local and facial skin, repair skin light aging, improve uneven skin, large pores, rough skin, the skin relaxation phenomena, especially applicable to dispel various scars and wrinkles, acne, tattoo, stains, and pigmentation, as well as on the surface of any part of a variety of moles, warts, acne, skin tag, treatment of hemangioma. vaginal tightening urinary incontence.
Thermal radiation make the shrink of mucosal tissue, collagen fibers improvement and restructuring so that the vaginal tightening.
I .Vaginal Tightening: rapid tightening, lasting constriction firmness increase 60%.
II. Vaginal Beautify: Dilute pigment, the labia pink increase 70%.
III.Vaginal moisten: increase secretion, eliminate dryness, lubrication increase 80 percent.
IV.Vaginal Young Maintain: Deep anti-aging, youth increase 80%.
Technical parameters of fractional CO2 laser
Laser wavelength |
10.6 μm ± 0.1μ M |
Three output mode |
Ultra pulse, continuous output and dot matrix output |
The output terminal of power |
1~40W |
Lattice point output energy of each |
5mj-100mj ( 16 speed adjustable ) |
Fractional output total energy |
125mj+1kj |
Scanner focal length |
f=50mm ( FFLS ) or f=100mm ( HFLS ) |
Focal spot diameter |
≤ 0.1mm≤ 0.2mm ( FFLS ), ( HFLS ) |
Treatment of depth |
2000μ m ( FFLS ), 600 μ m ( HFLS ) |
Guidelines for glory |
Green semiconductor laser ( 532nm,≤ 5mW ) |
System control |
microcomputer control |
Exhaust system |
built-in smoke system |
Cooling system |
built-in closed water cooling circulation system |
Display |
interface ( 10.4 inch color touch screen ) |
Light guide system |
2 joint torsion spring joint arm ( export) |
Way of working |
galvanometer scanning ( lattice ): |
FFLS scan size |
a maximum of 15*15mm |
HFLS scan size |
a maximum of 20*20mm |
The oval, triangular (standard and adjustable ) |
|
Scan rate |
>10m/s continuous: 1~30W, every step 1W adjustable; |
Pulse frequency modulation Pulse frequency modulation |
0-999Hz, every step 1Hz adjustable |
Environment temperature |
5~40 degree |
Relative humidity |
≤ 80% |
Power supply |
220V, 50Hz, 3A |
Dimensions |
500mm 650mm 1100mm |
Weight |
50kg |
Scanning pattern |
rectangle, square, triangle, circle, ellipse, straight line |
Pulse interval |
0-5000ms, every step 1ms adjustable |
LCD |
8/10.4 |
Advantage of Vaginal Tightening
360 degree automatic scanning technology to ensure uniform treatment to overcome the difficulty of the similar product, Can be integrated to improve a number of physiological functions of female private parts. There was no discomfort, no special care.Treatment can be repeated several times, with no side effects, Non-invasive and painless, no anesthesia.
Taboo
heart disease, high blood pressure, pregnant women, skin cancer , scar constitution, to avoid menstruation.
After treatment 15 days no sex.
Course of Treatment :1-3 times.