Disposable pressure transducer
Abbott, Edwards, Utah & BD connectors etc available.
Professional leading manufacturer.
ISO13485 & CE.
Company introduction
Zhejiang Haisheng Medical Devices Co.,Ltd is leading professional manufacturer of Anesthesia Consumables,Monitoring and Intervention Kits for 15years in China. Compliance with ISO9001:2008, ISO13485, CE, some are also got FDA. Haisheng factory area is more than 50,000square meters, its own research insitute was built in the same city, Shaoxing, Zhejiang province. We are always researching and developing new products to meet more people's requirements. We will support you timely delivery and good after-sales service.
More details can be offered by Clara, pls feel free to let her know.
Product Feature
1. Main parts of disposable IBP Transducer are imported, to ensure consistent and accurate readings during blood pressure monitoring.
2. Can make arterial pressure curve, find change of blood pressure easily
3. 3cc/hour flow rates.
4. Compatible with all guardianship equipment.
5. CE and ISO certificates, will get FDA soon.
6. Samplying easily
Connector types: Abbott, Edwards, BD, & Utah,USB,B.Braun
Pressure transducer kit includes:
-- Transducer
-- Infusion set
-- Pressure monitoring line
-- Stopcock etc
Application
Disposable pressure transducer is used to monitor real-time dynamic blood pressure and continue to transfer it to custody singal processing systems to obtain real-time ambulatory blood pressure of this physiological parameter for clinical disease diagnosis,treatment and prognosis on an objective basis.
Procedure
1.Ensure that the cable is compatible with the monitor being used. Connect the
reusable cable to the monitor, and turn the monitor on to allow the electronics
to warm up.
2. Using aseptic technique, remove the transducer and kit from the sterile
packaging.
3. Ensure that all connections are secure.
4. Flush the circuit with the heparinized IV flush solution and remove all air as per hospital policy.
5. When the whole circuit is filled with heparinized solution, secure the system set at the operating bed or other corresponding position. (Note: the pressure inducing chip should be at the same level of the midaxillary line of the patient.) Close the stopcock to the patient.
6. When puncture leads the indewelling needle the artery or central vein, connect the indwelling needle to the end to the patient.
7. Adjust the monitor to read zero mmHg as per the monitor operation mannual.
8. Open the stopcock and watch on the monitor the pressure wave patterns.