Model: | CT-4008-5V5mA |
---|---|
Brand: | NEWARE |
Origin: | - |
Category: | Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument |
Label: | Battery tester , Battery cycler , Battery charge |
Min. Order: | 1 pc |
Payment Terms: | TT |
Last Online:04 Nov, 2019 |
BTS-5V5mA 8 channels coin battery cycler
Test Items: cuttent, voltage, DCIR, Pulse Test, HPPC, Rate, Static capacity, cycle life and etc.
Type of battery test:Li-ion, LifePO4, Ni-MH, Ni-Cd, Lead acid , battery pack, EV/PHEV battery etc.
Different Specifications could be customized, Ranging from 1mA-3000A, 5-800V;
Our customers come from Samsung, LG, BYD, SAFT, University of oxford, University of Stanford, University of Wollongong, etc. making us one of the top companies in this area.
BTS-5V5mA Specification Sheets
Battery testing sysem Description |
Battery testing sysem Product Specification |
||||
AC Input |
AC 110V±10% 50Hz |
||||
Power |
354 |
mW |
|||
Resolution |
AD: 16bit; DA: 16bit |
||||
Input Impedance |
≥1MΩ |
||||
Voltage |
Measuring Range |
Charge: 10mV~5V |
Discharge: 10mV~5V |
||
Discharge Min Voltage |
10mV |
||||
Accuracy |
± 0.1% of FS |
||||
Stability |
± 0.1% of FS |
||||
Current |
Range |
Charge: 0.05mA~10mA Discharge: 0.05mA~10mA |
|||
Accuracy |
± 0.1% of FS |
||||
Stability |
± 0.1% of FS |
||||
Power |
Output Power Per Channel |
25mW |
|||
Stability |
± 0.2% of FS |
||||
Time |
Rise Time |
20ms (0~Full Range) |
|||
Step Time |
≤ (365*24) hour/step |
Time Format 00:00:00 (h:min:s) |
|||
Data Acquisition |
Intervals |
Time interval Δt:(1s~60000s) |
|||
Voltage interval ΔU: (10mV~5V) |
|||||
Current interval ΔI: (0.01mA~5mA) |
|||||
Frequency |
10Hz |
||||
Charge |
Modeof Operation |
CCC, CVC, CC & CVC,CPC,CC&CCC |
|||
End Conditions |
Voltage, Current, Test Time, Capacity, -△V |
||||
Discharge |
Modeof Operation |
CCD, CPD |
|||
End Conditions |
Voltage, Current, Test Time, Capacity, -△V |
||||
Pulse |
charge |
CCC ,Constant power mode |
|||
Discharge |
CCD,Constant power mode |
||||
Min Pulse Width |
500ms |
||||
Automated Switch |
Automated swith from charge to discharge for each pulse |
||||
End Condition |
Voltage, Test Time |
||||
DCIR testing |
Support DCIR testing |
||||
Cycle |
Loop Measure Range |
1~65535 times |
each channel of the analyzer has independent constant-current and constant
voltage source, which can be programmed and controlled by computer software.
And all the data can be exported to EXCEL and PDF sheets from DATA Analyze software.