Model: | CHE-24 |
---|---|
Brand: | - |
Origin: | Made In China |
Category: | Industrial Supplies / Other Industrial Supplies |
Label: | - |
Price: |
-
|
Min. Order: | 1 pc |
1.Scope of Application
This product is mainly used for detecting formaldehyde emission ,VOC emission for furniture, wood-based panel, indoor decoration and home appliance. That meets the standard of ASTME1333,ISO16000-9,EN717-1,ANSI/BIFMA X7.1-2007 Standards.
2.Technical Parameters
①Temperature: Range:(10~40)℃
Adjustment Precision:±0.5℃
Measurement Accuracy:±0.2℃
Rate of Temperature Variation≥0.2℃/min
②Humidity:
Range:(40~70)%RH.
Adjustment Precision:±3%R.H.
Error Tolerance:±2%R.H.
③Air flow rate:
Range:6m3~60m3/h (Air Exchange Rate:0.2~2Pcs/h,Stepless Adjustment.)
Adjustment Precision:Air Volume±1%
Error Tolerance:±0.01m3/h
④Face Velocity:On Horizontal,Total Cross-Section Air Circulation, Air Rate(0.1~0.3)m/s,Precision≤0.05m/s
⑤Dimension(Interior):24m³(Designed by actual site);
⑥Pressure:10±5Pa
⑦Tightness: At Static,1KPa,Leakage Rate≤1×10-3 m3/min
⑧Heat Preservation Box: Thickness of Polyurethane Board:120mm,
Exterior: White Painted Steel Plate;
Interior:304 Stainless Steel Board
⑨Clean Gas
No Load State:Background Concentration of Formaldehyde<0.006mg/m3 ,Background Concentration of TVOC<0.02mg/m³。Single Background Concentration of TVOC<0.002mg/m3
After gas enter :Concentration of Formaldehyde≤0.006 mg/m3,Single Concentration of TVOC≤0.002 mg/m3 ,Concentration of TVOC≤0.02 mg/m3
⑩All of the test conditions reach to a balance within 4 hours after starting.
3.Conditions:
①Room Temperature Range:(15~30)ºC
②Relative Humidity ≤80%
③Environment: Non-shock Non-corrosiveness, No Strong Magnetic Interference
④Voltage: 380V,Three-phase Four-wire System,Fluctuating range≤±10% of Nominal Voltage;Power:30KW
⑥Dimension:( Can be designed according to customer’s requirements & Actual site)
Interior Dimension(Studio):W3000mm×H2000mm×L4000mm
Dimension of Testing Chamber:W4050mm×H2640mm×L4580mm