Home > Products > Electronics & Electricity > Electronic Instrument > Air & Gas Flowmeter

HN-UHZ-300 Series Magnetic turned column 1HN-UHZ-300 Series Magnetic turned column 2HN-UHZ-300 Series Magnetic turned column 3
  • HN-UHZ-300 Series Magnetic turned column 1
  • HN-UHZ-300 Series Magnetic turned column 2
  • HN-UHZ-300 Series Magnetic turned column 3

HN-UHZ-300 Series Magnetic turned column

Model:HN-UHZ-300
Brand:Harhn
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Air & Gas Flowmeter
Label:Level
Price: ¥4000 / pc
Min. Order:1 pc
Inquire Now

Member Information

Detail

Product Description

Level of magnetic flap profile:
    HN-UHZ-300 Series Magnetic turned column (Magnetic turned column) level gauge is based on magnetic coupling principle, the principle of communicating vessels, Archimedes (buoyancy) and other principles of a clever combination of the characteristics of mechanical drive and developed a level measurement device designed for.
    This type of instrument has a float receiving cavity (referred to as the main pipe or casing), which form a flange or other communication via the interface and the container; such that the liquid level within the chamber with the liquid level within the container is the same height, so the cavity will float with the liquid level in the container while lifting the lift; this time we installed a turned column display outside of the cavity, as we float in the manufacture of liquid in the sink float the junction portion of the installed floating magnet, when it float with the lift surface, it passes through the magnetic housing to turn column display, push turned column magnetic flip 180 °; the magnetic turned column is red, two semi-cylindrical white synthetic cylinder, flipped 180 ° so after the column turned toward the outside of the display will change color (below the surface of the red, white above), that is at the junction of the two-color liquid surface height.

HN-UHZ-300 magnetic level gauge
First, the principle and structure of work
    Magnetic turned column (Magnetic turned column) level gauge is based on the principle of magnetic coupling, Archimedes (buoyancy) and other principles of a clever combination of the characteristics of mechanical drive and developed a special means for level measurement.
    This type of instrument has a float receiving cavity (referred to as the main pipe or casing), which form a flange or other communication via the interface and the container; such that the liquid level within the chamber with the liquid level within the container is the same height, so the cavity will float with the liquid level in the container while lifting the lift; this time we can not see the liquid level, so we installed a turned column display outside of the cavity, because we manufacture the float in the float and sink into the liquid portion of the junction leak installed magnets, when it float with the lift surface, it passes through the magnetic housing to turn column display, push turned column magnetic flip 180 ° ; the magnetic turned column is red, white two semi-cylindrical synthetic cylinder, flipped 180 ° so after the column turned toward the outside of the display will change color (below the surface of the red, white above), that is at the junction of two color liquid surface height.
    Instruments with level transmitter (remote electrical signal), the level transmitter section (electrical part) works by using a magnetic float circuit connected to the role of lead resistance changes in the number of magnetic reed switch, and then, so that the sensor portion may occur due to changes in the level corresponding to the resistance signal. Through the signal converter, the resistance of the signal can be converted to the 4 ~ 20mA current signal. Electronic device of the present level gauge almost no capacitors, inductors and other energy storage components. Can be superimposed HART communication protocol, you can also use RS485 communication bus.

Second, product characteristics
    The gauge is based on similar products from home and abroad, and actively absorb, combines the advantages of many products through the company's technical staff of well-designed, high-quality magnets and imports of electronic components. Products are:
    Measuring range, intuitive readings clear;
    Sealing engagement less surface, easy to leakage, safe and reliable;
    Indicating portion completely isolated with the measured medium;
    Easy to install, easy maintenance.

Third, the main technical parameters
 
Normal working conditions:
    Ambient temperature: -20 ~ 80 ℃;
    Relative humidity: 5% to 100% (including direct wet);
    Environmental pressure: 86kPa ~ 108 kPa;
    Measuring range: 0 ~ 12 m (optional);
    Display accuracy: ± 10 mm;
    Medium pressure: 25.0 MPa and below (optional);
    Medium temperature: -40 ~ 450 ℃ (type optional);
    Medium density: ≥.0.5g / cm3;
    ? Medium viscosity: ≤0.05Pa S;
    Wetted material: stainless steel, PVC, Ti and the like;
    Connection: flange, thread (according to user needs);

Alarm switch:
    Contact capacity: AC220V 0.5A or DC24V 0.8A;
    Switch Type: passive dry contact;
    Switch Type: normally open, normally closed, self-holding;
    Electrical life:> 10 million times (about power and control);
    Limit load current: 3A (some models);
    Maximum contact resistance: 150mΩ.

Transmission output modules:
    Output signal: 4 ~ 20mA / HART / RS485;
    Load Resistance: 500Ω (24VDC power supply at the time)
    Power supply: DC24V, 50mA;
    Ambient temperature: -40 ~ 60 ℃;
    Accuracy:
        Measurement Range (m): 0 ~ 0.5 [± 2%] 0.5 ~ 2 [± 1.5%]> 2 [± 1%]
    And outlet: M20 × 1.5 (default);
    Proof in the form: flameproof Ex dⅡCT6, intrinsically safe Ex iaⅡCT6.

Fourth, use and scope of application (see table)
    With the changes in market demand, Hahn (Dalian) Co., Ltd. fluid control technology products are constantly upgrading technology to achieve improved quality and production processes, to broaden the field of application of the gauge and application. In addition, the output signal level meter varied to achieve long-distance level indication, detection, control and recording. It can be applied to a variety of industrial automation and process control level measurement and control. Widely used in petroleum processing, municipal, food processing, chemicals, water treatment, pharmaceutical, power, paper making, metallurgy, shipbuilding and boiler level measurement, control and monitoring.

If unknown, please contact customer service!


Payment Terms:TT

Product Image

HN-UHZ-300 Series Magnetic turned column 1
Img 1
HN-UHZ-300 Series Magnetic turned column 2
Img 2
HN-UHZ-300 Series Magnetic turned column 3
Img 3

Send Inquiry to this Member

HarHn (DaLan)Fluid control Technology Co.,Ltd

Hi-tech Park, Huangpu, Room 156 101

Phone:
86-0411-84710032
Fax:
86-0411-84710032
Contact:
ouyang (Sales Manager)
Mobile:
13842856816

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Air & Gas Flowmeter Made In China Products

,  

Air & Gas Flowmeter China Suppliers and China Manufacturers