4 zones conventional fire alarm security host control panel	CK1004 14 zones conventional fire alarm security host control panel	CK1004 24 zones conventional fire alarm security host control panel	CK1004 34 zones conventional fire alarm security host control panel	CK1004 44 zones conventional fire alarm security host control panel	CK1004 5
  • 4 zones conventional fire alarm security host control panel	CK1004 1
  • 4 zones conventional fire alarm security host control panel	CK1004 2
  • 4 zones conventional fire alarm security host control panel	CK1004 3
  • 4 zones conventional fire alarm security host control panel	CK1004 4
  • 4 zones conventional fire alarm security host control panel	CK1004 5

4 zones conventional fire alarm security host control panel CK1004

Model:ck1004
Brand:zc
Origin:Made In China
Category:Security & Protection / Fire Fighting
Label:control panel , security panel , alarm host
Price: US $130 / pc
Min. Order:1 pc
Inquire Now

Member Information

Detail

Product Description

Conventional Fire Alarm Control System :Conventional Fire Alarm Control Panel
 



 

General

Conventional Fire Alarm Control Panel with four Zones

Key Specifications/Special Features

  • Four Style B (Class B) Initiating Device Circuits (IDCs).
  • All zones accept two-wire smoke detectors and any normally-open contact devices.
  • One built-in, Style Y (Class B) Notification Appliance (Signal) Circuits (NACs).
  • Alarm, Trouble and Supervisory, Form-C relays standard.
  • 24-volt operation.
  • Resettable four-wire smoke detector power @ 500 mA.
  • Non-resettable power @ 500 mA.
  • One-man walk-test programmable for silent or audible test.
  • Disable/Enable control per IDC.
  • Reverse polarity protection.

Specifications

 

AC Power

90-270 VAC, 50 Hz, 2.3 amps

Wire size: minimum #14 AWG (2.0 mm2) with 600V insulation

Battery (lead acid only)

Maximum Charging Circuit: Normal Flat Charge—27.6V @ 0.8 amp

Maximum Charger Capacity: 18 Amp Hour batter

Sound Output Device Circuits

General Alarm Zones 1 through 16

Operation: All zones Class B

Normal Operating Voltage: Nominal 24 VDC (ripple = 100 mV maximum)

Alarm Current: 15 mA threshold

Short Circuit Current: 42 mA maximum

Maximum Loop Resistance: 100 ohms

End-of-Line Resistor: 4.7K, ½ watt

Detector Loop Current is sufficient to ensure operation of two alarmed detectors per zone

Standby Current: 7.26 mA

Three Relays Output

Relay contact rating: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive)

Nonresettable 24 VDC Power

Maximum ripple voltage: 10 mVRMS          Operating Voltage nominal 24 volts

Total DC current available from this output is up to 500 mA

Recommended maximum Standby current is 150 mA

 


Payment Terms:T/T,WU,PAYPAL

Product Image

4 zones conventional fire alarm security host control panel	CK1004 1
Img 1
4 zones conventional fire alarm security host control panel	CK1004 2
Img 2
4 zones conventional fire alarm security host control panel	CK1004 3
Img 3
4 zones conventional fire alarm security host control panel	CK1004 4
Img 4
4 zones conventional fire alarm security host control panel	CK1004 5
Img 5

Send Inquiry to this Member

ShenZhen Zoanco Electronics Co ., Ltd

4F, Building B1, XinHaoSheng High-Tech Park, YongHe Road, FuYong Town, Baoan District, Shenzhen, China

Phone:
86-0755-23015236
Fax:
86-0755-23015236
Contact:
Jenny Ning (manager)
Mobile:
15220176087

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Fire Fighting Made In China Products

,  

Fire Fighting China Suppliers and China Manufacturers