Model: | MM420 440series |
---|---|
Brand: | SIEMENS |
Origin: | Made In Germany |
Category: | Electronics & Electricity / Transducer |
Label: | inverter , MM420 , MM440 |
Price: |
-
|
Min. Order: | 1 pc |
Last Online:28 Nov, 2024 |
MM420/2 series, 220V,1/3 phases ,0-650HZ, | ||||
Type | Order No. | power KW | current:A | size:(WXHXD) mm |
MM420-75/2 | 6SE6420-2UC17-5AA1 | 0.75 | 3.9 | 73X173X149 |
MM420-150/2 | 6SE6420-2UC21-5BA1 | 1.5 | 7.4 | 149X202X172 |
MM420-220/2 | 6SE6420-2UC22-2BA1 | 2.2 | 10.4 | 149X202X172 |
MM420/3 series, 380V-500v ,0-650HZ, | ||||
MM420-75/3 | 6SE6420-2UD17-5AA1 | 0.75 | 2.1 | 73X173X149 |
MM420-150/3 | 6SE6420-2UD21-5AA1 | 1.5 | 4 | 73X173X149 |
MM420-220/3 | 6SE6420-2UD22-2BA1 | 2.2 | 5.9 | 149X202X172 |
MM420-300/3 | 6SE6420-2UD23-0BA1 | 3 | 7.7 | 149X202X172 |
MM420-400/3 | 6SE6420-2UD24-0BA1 | 4 | 10.2 | 149X202X172 |
MM420-550/3 | 6SE6420-2UD25-5CA1 | 5.5 | 13.2 | 185X245X195 |
MM420-750/3 | 6SE6420-2UD27-5CA1 | 7.5 | 18.4 | 185X245X195 |
MM420-1100/3 | 6SE6420-2UD31-1CA1 | 11 | 26 | 185X245X195 |
MM440/2 vector ,220VAC,1/3 phases ,0-650HZ, | ||||
Type | Order No. | power KW | current:A | size:(WXHXD) mm |
MM440-75/2 | 6SE6440-2UC17-5AA1 | 0.75 | 3.9 | 73X173X149 |
MM440-150/2 | 6SE6440-2UC21-5BA1 | 1.5 | 7.4 | 149X202X172 |
MM440-220/2 | 6SE6440-2UC22-2BA1 | 2.2 | 10.4 | 149X202X172 |
MM440/3 vector ,380-500VAC,0-650HZ | ||||
MM440-75/3 | 6SE6440-2UD17-5AA1 | 0.75 | 2.1/2.1 | 73X173X149 |
MM440-110/3 | 6SE6440-2UD21-1AA1 | 1.1 | 3.0/3.0 | 73X173X149 |
MM440-150/3 | 6SE6440-2UD21-5AA1 | 1.5 | 4.0/4.0 | 73X173X149 |
MM440-220/3 | 6SE6440-2UD22-2BA1 | 2.2 | 5.9/5.9 | 149X202X172 |
MM440-300/3 | 6SE6440-2UD23-0BA1 | 3 | 7.7/7.7 | 149X202X172 |
MM440-400/3 | 6SE6440-2UD24-0BA1 | 4 | 10.2/10.2 | 149X202X172 |
MM440-550/3 | 6SE6440-2UD25-5CA1 | 5.5/7.5 | 13.2/18.4 | 185X245X195 |
MM440-750/3 | 6SE6440-2UD27-5CA1 | 7.5/11 | 18.4/26.0 | 185X245X195 |
MM440-1100/3 | 6SE6440-2UD31-1CA1 | 11.0/15 | 26.0/32.0 | 185X245X195 |
MM440-1500/3 | 6SE6440-2UD31-5DA1 | 15/18.5 | 32.0/38.0 | 275X520X245 |
MM440-1850/3 | 6SE6440-2UD31-8DA1 | 18.5/22 | 38.0/45.0 | 275X520X245 |
MM440-2200/3 | 6SE6440-2UD32-2DA1 | 22/30 | 45.0/62.0 | 275X520X245 |
MM440-3000/3 | 6SE6440-2UD33-0EA1 | 30/37 | 62.0/75.0 | 275X650X245 |
MM440-3700/3 | 6SE6440-2UD33-7EA1 | 37/45 | 75.0/90.0 | 275X650X245 |
MM440-4500/3 | 6SE6440-2UD34-5FA1 | 4555 | 90.0/110. | 350X850X320 |
MM440-5500/3 | 6SE6440-2UD35-5FA1 | 55/75 | 110/145 | 350X850X320 |
MM440-7500/3 | 6SE6440-2UD37-5FA1 | 75/90 | 145/178 | 350X850X320 |
Voltage and power ranges | 200-240 V, ± 10%, 1 AC, 0.12 to 3 kW (0.16 to 4 HP)
200-240 V, ± 10%, 0.12 to 45 kW (0.16 to 60 HP) 380-480 V, ± 10%, 0.37 to 250 kW (0.5 to 350 HP) 500-600 V, ± 10%, 0.75 to 90 kW (1.0 to 125 HP) |
Operating temperature | 0.12 to 75 kW (0.16 to 1.0 HP) (CT): -10 °C to +50 °C
90 to 200 kW (125 to 276 HP) (CT): 0 °C to +40 °C |
Process control | Internal PID controller (autotuning) |
Types of control | Vector control, FCC (Flux Current Control), multipoint characteristic (parameterizable V/f characteristic), V/f characteristic |
Inputs | 6 digital inputs, 2 analog inputs, 1 PTC/KTY input |
Outputs | 2 analog outputs, 3 relay outputs |
Link-up to automation | The ideal partner for your automation needs, from connection to SIMATIC S7-200 to integration in TIA with SIMATIC and SIMOTION. |
Compact housing
Easy to install
Sophisticated vector control (speed/torque)
Versatile inputs and outputs
Guided commissioning
High overload capacity
Evaluation of motor pulse encoders (optional) for maximum control of torque at the lowest speeds (even at zero speed)
Modular system of extension options
Can be dimensioned for CT (constant torque) or VT (quadratic, i. e. variable torque)
3 selectable drive data to adapt the inverter to different operating circumstances
Load torque monitoring
|
Kinetic buffering against voltage dips
Compound braking for controlled rapid braking
Integrated brake chopper for power outputs up to 90 kW (125 HP)
Free function blocks
4 skip frequencies minimize machine stress when resonance occurs
Automatic restart
Minimal stress on motor when inverter connected to rotating motor
Evaluation of motor temperature for integrated motor protection
Prepared for use in IT networks
Available with and without integrated EMC filter
|