Model: | PM series |
---|---|
Brand: | HRD |
Origin: | Made In China |
Category: | Electronics & Electricity / Power Supply & Distribution / UPS |
Label: | Rack Mount UPS , High Frequency UPS , online UPS |
Price: |
US $210
/ pc
|
Min. Order: | 5 pc |
Last Online:02 May, 2017 |
Product Name: | Rack Mounted Ups | Model: | PMR01S,PMR01L,PMR02S |
Capacity: | 1KVA/0.8kW,1KVA/0.8kW,2KVA/1.6kW | Phase: | Single |
Input PF: | Above 0.98 | THDi: | Less Than 5% |
1KVA - 10KVA Rack Mount UPS / 19 Inch LCD Double-Conversion UPS
PM series rack mount online UPS 1-3kva | |||||||
Perfect Application: | |||||||
Computer center, network center, communication system | |||||||
automatic control system data center or other critical systems. | |||||||
|
|||||||
Main Features: | |||||||
19inch,2U and 3U Rack mount | |||||||
High frewuency and online double conversion | |||||||
Wide input voltage (110-285Vac or 65-148Vac) | |||||||
Self-diagnosis system at ups start | |||||||
Digital control technoloy and advanced PFC | |||||||
Output PF0.8,(0.9 optional) | |||||||
Lighting and surge protection 1050j | |||||||
Generator compatible | |||||||
Smart RS232(USB,SNMP OPTIONAL) | |||||||
EMI/RFI noise filter | |||||||
Overview | |||||||
With true double-conversion design, PowerMaster series provides powerful and overall protection to your sensitive devices. It can accept wider input voltage for harsh environment. It's perfect protection for your precisous servers and workstaiosn. | |||||||
Specifications | |||||||
Model | PMR01S | PMR01L | PMR02S | PMR02L | PMR03S | PMR03L | |
Capacity | 1KVA/0.8kW | 1KVA/0.8kW | 2KVA/1.6kW | 2KVA/1.6kW | 3KVA/2.4kW | 3KVA/2.4kW | |
Phase | Single | ||||||
Input voltage | |||||||
Input PF | above 0.98 | ||||||
THDi | less than 5% | ||||||
Rated voltage | 220v/230v/240Vac or 110/120/127Vac | ||||||
Input voltage range | Low line transfer:176 VAC ± 3% @ 100% load
130 VAC ± 3% @ 50% load 85-148Vac( for 110/120/127Vac) |
||||||
Low line comback:188VAC ± 3% @ 100% load
142 VAC ± 3% @ 50% load; 100vac±5Vac(110/120/127Vac) |
|||||||
High Line Transfer:286 ± 3%148Vac ± 3%(for 110/120/120vac); | |||||||
High Line Come Back:271 ± 3%;
145Vac±5Vac(110/120/127Vac) |
|||||||
Rated frequency | 50/60hz(auto sensing) | ||||||
Input frequency range | 46~54 Hz ◎ 50 Hz / 56~64 Hz ◎ 60 Hz | ||||||
By-pass input | |||||||
Input voltage range | 170VAC—270VAC±5V | ||||||
Frequency following range | 46~54 Hz ◎ 50 Hz / 56~64 Hz ◎ 60 Hz | ||||||
Recharge battery | |||||||
Floating charge voltage | 28/41VDC | 55/84/110VDC | 84/110VDC | ||||
Recharging current | 1A(inbuilt battery) | 8A | 1A(Rack batt.case) | 8A | 1A(Rack batt.case) | 8A | |
Battery | |||||||
Battery quantity | 24/36VDC | 48V/72/96VDC | 72/96VDC | ||||
AC output | |||||||
Power factor | 0.8 | ||||||
Phase | single | ||||||
Rated voltage | 220v/230v/240v+/-1.5% | ||||||
Frequency | 50/60hz | ||||||
Frequency stability | ±0.1HZ(battery inverter) | ||||||
Voltage stability | within±1.5%( Static) | ||||||
Crest factor | 3:1(max) | ||||||
Wave distortion | Linear load less 3%,Non-linear load less 5%; | ||||||
Over load ability | 30s when overload is 108%~150%;200ms above 150%; | ||||||
Transfer time | 0ms | ||||||
Alarm | |||||||
AC abnomal | Alarm every 4 seconds | ||||||
Battery low voltage | Keep alarm every 1 second | ||||||
Overload | Keep alarm every 0.5 second | ||||||
Failure | Keep alarm | ||||||
System | |||||||
Efficiency | above 87% | ||||||
Display | LCD+LED | ||||||
Protection |
Output short circuit , Overload , Output low voltage, Battery low voltage, Over-temperature etc. |
||||||
over-voltage protection,over-tempreture protection for charger PCB,and soft-start function for each function module. | |||||||
Infterface | RS232(USB OPTIONAL) | ||||||
Working Temp. | 0~40℃ | ||||||
Relative humidity | 0~90%( No coagulation) | ||||||
Cooling | Intelligent speed-control Fan | ||||||
Input & output | Socket(Optional) | ||||||
Others | |||||||
Surge protection | IEC60664—1 Graded protection | ||||||
EMI | EN 55022 Grade A | ||||||
ESD | IEC 1000-4-2:Grade 3 | ||||||
EFT | IEC 1000-4-4:Grade 3 | ||||||
RS | IEC 1000-4-3:Grade 3 | ||||||
SURGE | IEC 1000-4-5:Grade 3 | ||||||
Physical | |||||||
Weight(N/G)kgs | 12.5/14.5 | 7.0/8.0 | 11.0/13.0 | 28.0/31.0 | 11.0/13.0 | 28.0/31.0 | |
Unit Size
(D*W*H) |
440* 440 *87 mm | 440* 440 *87 mm(long run model) | |||||
440* 440 *134 mm( inbuilt battery model) | |||||||
Packing Size
(D*W*H) |
570*570*185mm | 570*570*185mm(long run model),2U | |||||
640*570 *230mm( inbuilt battery model),3U |
|
|||||||||||
•19'inch, rack mount, 3/4U design 6kva to 10kva | |||||||||||
•True online high frequency double-conversion | |||||||||||
•Advanced DSP controlled ,excellent performance with super high quality | |||||||||||
•Output Power Factor 0.9 | |||||||||||
•Wide input frequency range (40-70Hz) | |||||||||||
•Wide input voltage range | |||||||||||
•50Hz/60Hz frequency converter mode | |||||||||||
•Eco mode operation for energy saving (Optional) | |||||||||||
192Vdc and 240Vdc convertible easily | |||||||||||
•Emergency power off function (EPO) | |||||||||||
History event record function,100 events | |||||||||||
•Cold start and AC start function | |||||||||||
•Automatic 4 levels speed fan control according to load and temperature | |||||||||||
•Advanced N+1 redundancy parallel technology(Max.6units) | |||||||||||
•Support any kinds of Generator | |||||||||||
PC Plus RACK MOUNT 6K/10K ONLINE HF UPS | |||||||||||
MODEL | PCPR 06S | PCPR 06L | PCPR 10S | PCPR 10L | |||||||
PHASE | 1 phase in / 1 phase out | ||||||||||
CAPACITY | 6Kva / 5.4Kw | 10Kva/ 9Kw | |||||||||
INPUT | |||||||||||
Voltage Range | Low Line Transfer | 176 VAC ± 3% @ 100% load
130 VAC ± 3% @ 50% load |
|||||||||
Low Line Comeback | 188 VAC ± 3% @ 100% load
142 VAC ± 3% @ 50% load |
||||||||||
High Line Transfer | 286 VAC ± 3% | ||||||||||
High Line Comeback | 270 VAC ± 3% | ||||||||||
Frequency Range | 40-70Hz
following range 46~54 Hz @ 50Hz ,56~64 Hz @60Hz |
||||||||||
Phase | Single phase with ground | ||||||||||
Power Factor | > 0.99 @ 100%load | ||||||||||
OUTPUT | |||||||||||
Output Voltage | 208/220/230/240 VAC | ||||||||||
AC Voltage Regulation | ± 1% | ||||||||||
Frequency Range (Synchronized Range) | 46~54 Hz @ 50 Hz / 56~64 Hz @ 60 Hz | ||||||||||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||||||||||
Current Crest Ratio | 3:1 (max.) | ||||||||||
Harmonic Distortion | ≤ 3 % THD (Linear Load) , ≤ 6 % THD (Non-linear Load) | ||||||||||
Transfer Time | AC Mode to Batt. Mode | Zero | |||||||||
Inverter to Bypass | Zero | ||||||||||
Waveform (Batt. Mode) | Pure Sinewave | ||||||||||
EFFICIENCY | |||||||||||
AC Mode | 92% | ||||||||||
Battery Mode | 91% | ||||||||||
BATTERY | |||||||||||
Standard model | Battery Type | lead-acid battery maintanence free | |||||||||
Numbers | 16/20Pcs | ||||||||||
Typical Recharge Time | 3 hours recover to 90% capacity | 4 hours recover to 90% capacity | |||||||||
Charging Current (max.) | 1A ±10% | 4A±10% | 1A ±10% | 4A ±10% | |||||||
Charging Voltage | 220/273 VDC ± 1% | ||||||||||
Long-run Model | Battery cabinet | 16/20pcs 7ah | without batt. | 16/20pcs9ah | without batt. | ||||||
INDICATORS | |||||||||||
LCD Panel | UPS status, Load level, Battery level, Input/Output voltage,
output current,Bus voltage, Temp, and warning and fault code and events |
||||||||||
ALARM | |||||||||||
Battery Mode | Sounding every 4 seconds( can mute) | ||||||||||
Low Battery | Sounding every second | ||||||||||
Overload | Sounding every second | ||||||||||
Fault | Continuously sounding | ||||||||||
PHYSICAL | |||||||||||
Standard Model | Dimension,
D X W X H (mm) |
UPS Unit : 580 X 438 X 176 [4U]
Battery Pack : 580 X 438 X 176 [4U] |
UPS unit: 580 X 438 X 176[4U] | UPS Unit: 668 X 438 X 176 [4U]
Battery Pack : 580 X 438 X 176 [4U] |
UPS unit: 668 X 438 X 175[4U] | ||||||
Net Weight (kgs) | UPS Unit : 22 kgs
Battery Pack : 62kgs |
22kgs | UPS Unit : 25 kgs
Battery Pack :75 kgs |
25kgs | |||||||
ENVIRONMENT | |||||||||||
Operation Humidity | 20-90 % RH @ 0- 40°C (non-condensing) | ||||||||||
Noise Level | Less than 55dBA @ 1 Meter | Less than 58dBA @ 1 Meter | |||||||||
MANAGEMENT | |||||||||||
Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC | ||||||||||
Optional SNMP | Power management from SNMP manager and web browser |
Payment Terms: | TT or WU |
---|---|