SNV-309 Remote Wireless Communication Terminal of Overhead Fault Indicator 1SNV-309 Remote Wireless Communication Terminal of Overhead Fault Indicator 2SNV-309 Remote Wireless Communication Terminal of Overhead Fault Indicator 3SNV-309 Remote Wireless Communication Terminal of Overhead Fault Indicator 4SNV-309 Remote Wireless Communication Terminal of Overhead Fault Indicator 5
  • SNV-309 Remote Wireless Communication Terminal of Overhead Fault Indicator 1
  • SNV-309 Remote Wireless Communication Terminal of Overhead Fault Indicator 2
  • SNV-309 Remote Wireless Communication Terminal of Overhead Fault Indicator 3
  • SNV-309 Remote Wireless Communication Terminal of Overhead Fault Indicator 4
  • SNV-309 Remote Wireless Communication Terminal of Overhead Fault Indicator 5

SNV-309 Remote Wireless Communication Terminal of Overhead Fault Indicator

Model:SNV-309
Brand:SNOVA
Origin:Made In China
Category:Electronics & Electricity / Electric Control System
Label:Fault Indicator , RADIO & TTE , Ground&Short circuit
Price: US $1 / sets
Min. Order:10 sets
Inquire Now

Member Information

Detail

Product Description

SNV-309 wireless communication terminal of overhead 
type grounding and short circuit fault indicator

SNV- 309 the wireless communication terminal is used to realize the 
communication between the aerial grounding and short circuit fault 
indicator and the remote server
SNV- 1000; 
As a bridge of communication between the fault indicator and the 
remote server,
SNV- 309 wireless communication terminal has been in 
the work of the state, on the one hand waiting for fault indicator to 
upload data, on the other hand maintain real-time communication with 
the remote server, the fault indicator of the latest data uploaded to the 
remote server changes. And the remote server to download the new 
parameters set up temporarily in its own memory, waiting for the next 
fault indicator communication, will be downloaded to the fault indicator. 
SNV- 309 wireless communication terminal uses 6.2V rechargeable 
lithium iron phosphate battery as the main power source. Through the 
internal battery charging management circuit so that solar panels and 
batteries have been in the best state of charge and discharge.

 

Product function

■ Processing and conversion, storage and 
management of fault indicator upload data 
■ Support the free configuration of the upload point 
table (direct parameter configuration does not need 
to be modified) 
■ Multiple set of sensors can be configured for a 
terminal
■ Manage the operating parameters of the fault 
indicator and download it to the fault indicator at the 
appropriate time. 
■ In real-time communication with the remote 
server, the fault indicator will be uploaded to the 
server.
■ Standard transport protocol set of 5- IEC60870- 
1001 (support for a variety of length 101)

■ Telemetry and telemetry 
■ Parameter setting of the terminal by short 
message 
■ Receive fault indicator upload data 
■ Support remote reset, clear fault flag
■ PC through the RS232 to its parameter 
settings 
■ Grounding fault current monitoring and 
the judgment of earth fault 
■ Support remote online program update 
and local serial port program upgrade
■ By holding PDA in the field of the terminal 
parameters settings 
■ Low power consumption, 7Ah 6V lithium 
iron phosphate battery can be standby for15days

 

If you are interested in our products ,please contact with us .

Contact:Andrew Mao

Email:@163.com or 626387134@qq.com

Mobile:0086-13570657698

Wechat :13570657698  QQ:626387134

 

1,Summarize

 

1.1, Intelligent overhead line fault indicator

It can detect the short-circuit fault, ground fault and measure the line current operating condition accurately. It can communicate two-way real-time with the communication terminal through the wireless. So that it can report the fault status and line operating condition to the communication terminal real-timely. Also, it can receive the test signal, configuration parameter and upgrade programme realtimely from the communication terminal 

 

1.2. Overhead type data collecting communication terminal

It is used fortwo-way real-time connectionbetween the wireless remote real-time condition monitoring system and the intelligent overhead line fault indicator. It can report the monitor result to the system, such as fault status and line operation status. At the same time, it can receive the order from the system.

 

 

 1.3. Wireless remote real-time condition monitoring system

It can collect the fault status and line operation condition from the communication terminal. It can also display monitoring results, alarm, storage and printing. It can also control the parameters of intelligent overhead line fault indicator and its upgrade programme.

 

Intelligent Overhead line short-circuit and ground fault indicator

 

2.Features

  

Self-sustain

Short-circuit fault detection

The indicator is made with new material and special circuit designed. When the wire load current is greater than 3A, it begins to get the power from the wire. When the wire load current is greater than 30A, it can work normally without the lithium battery totally.

We use quick break over-current two-stage current or adaptive load current flow mutation current protection principle, and line running status detection, it can effectively inhibit the closing and reclosing inrush current and feedback to send electrical misoperation (the parameters can be set on-line so that the detection can be more sensitive and reliable).

Ground fault detection

Indication

It can monitor the mutational increment of the grounding current(the parameters can be set on-line so that the detection can be more sensitive and reliable).

The indication is done by three flashing LEDs for a clear visibility and three red display areas work by motor for a clear daytime visibility.

Single-flashing means ground fault indication; double-flashing means short-circuit fault indication.

Reset mode

Current and voltage measurement

1,1~48h timing reset(can be set on-line, default 24h)

2,Intelligent reset(auto-reset after finish the emergency repair and restoring power transmission)or local/remote control reset via wireless.

Real-time monitoring of line load current, wire-to-ground voltage induction, instead of using current transformers and live displays.

Live mounted and removal

Antirust design

The indicator can be mounted under live conditions with the help of an adapter and a hot stick.

The tension discs are made of high quality nylon material. The groove springs are made of stainless steel so that they won’t melt with the wire. The thread jamming structure parts are made of stainless steel and with antirust design.

Anti refuse operation design

Anti misoperation design

We adopt large cross-section design of magnetic circuit, it has good permeability performance, accuracy measurement and high sensitivity. They can be very sensitive no matter in the rural power line small load current or small mutations conditions or in the city network line two phase short circuit or slow flow conditions.

It has anti misoperation design, when the inrush current occurs after the non-loading line is switched on and anti misoperation of non fault branch when it’s on.

 

Communication mode

Embedded short-range two-way wireless communication frequencyRF modules, the GPRS data can communicate via data collection terminal or wireless repeater.

 

  

3. Technical parameters

  

Battery

6.5Ah/3.6V one long-life lithium battery

Electric power

50uA~20mA/3.6V(Corresponds to a load current 3A~600A)

Static average power consumption

40uA/3.6V (RF in parameter and command receiving waiting state)

Dynamic average power consumption

≤50uA / 3.6V (RF transmit data once every five minutes);

≤60uA / 3.6V (RF transmit data once per minute)

Available wire diameter

8~40mm(Insulated wire, bare wire)

Available load current

0~600A(Default),0~100A,0~2000A,0~4000A

Available voltage level

≤35KV(can be set according to the customer)

 Quick-break over current Delay

0~9.99S, Stepping by 0.01s (can be set via local wireless and GPRS on-line remote control)

Quick-break, over current settings

0~700A or 0~4000A (Phase sequence), 0~70A (Zero sequence), Stepping by 1A(can be set via local wireless and GPRS on-line remote control)

Maximum earth impedance

500Ω

Maximum short circuit current

40KA

Communication frequency (RF)

Center frequency: 434MHz, 64 channels automatic frequencyadjustment, two-way communication

Communication distance (RF)

30~100m(10dbm,open area);100~300m(20dbm,open area)

Voltage Linearity

Better than ±5%

Current Accuracy

±1%( when the load current≥20A) or ±1A(Load current<20A)

Short-circuit and ground fault indication

Three flashing LEDs and three red display areas. Single-flashing means ground fault indication; double-flashing means short-circuit fault indication.

Ambient temperature

-35~70℃

Protection class

IP65

Time of operation

>5000 times

Relative humidity

≤95%

Operating Altitude

≤2000m

Weight

≈500 g

Life

≥10 years

Maximum wind velocity

35 m/s

Seismicity

0.1g

Visual angle

360°  

 

4.Fault criterions

 

 

 

When the short-circuit fault occurs, we can shortly find out the fault point. For example, if the line 2 # phase B 2, 5 ,8 indicators and phase C 3, 6,9 indicators turn red display and 11,12 indicators are staying white display, then it can be judged that the point D has occurred short-circuit fault.

 

The line 2 # phase C 3, 6, 9 indicator day turn, and 12 indicator is still white, it can be judged a point D happen fault.

 

4.1,Short-circuit fault criterions (Embedded wireless frequency adjustment module, so that the parameters can be set online)

(1)Quick break, over current criterion

  • Live line lasts for more than 30s, current≥10A or Voltage to groud≥3KV
  • Quick-break and over-current two-stage over-current protection value start: 0~700A/0~9.99s
  • Line in power-cut status, current≤5A and Voltage to ground ≤ 70% (in 10 seconds)

  The indicator will shut off the above function automatically when the quick break, over current set to 700A, and the adaptive load current’s over-current mutation criterion starts.

(2) Adaptive load current’s over-current mutation criterion.

  • Live line lasts for more than 30s, current≥10A or Voltage to ground≥3kV
  • The fault startup conditions:

                  When the load current IL≤200A, ΔI ≥100A

                  When the load current IL>200A, ΔI ≥1/2*IL

  • Fault duration: ≤10Sec
  • Line outage: load current≤5A and voltage to ground ≤ 1kV

 

4.2,Ground fault criterions(Embedded wireless frequency adjustment module, so that the parameters can be set online)

  • Live line lasts for more than 30s, Voltage to ground ≥3KV
  • The first half wave increment: ≥ 30A
  • Earth-phase voltage drop ratio: ≥ 30%
  • Earth-phase voltage reduction time: ≥ 60s
  • The total current of earth-phase: ≥ 10A

 

5. Intelligent overhead data collecting communication terminal

    Intelligent Overhead line short-circuit and ground fault indicator

 

5.1. Summarize

Overhead type data collecting communication terminal CSM-FTU4-I is mainly used for fault indicators signal transmission, fault locating and real-time online monitor system, and send the data to the communication station via GPRS. Furthermore, it can receive the communicate station link circuit query, link circuit reset, information collecting, remote control (data acquisition unit resets, indicator flashes/resets ), remote setting (parameters of data acquisition unit and indicator) orders. It collects the operation information, load current /short circuit operation current, the first half-wave peak current/grounding operation current and data of electric field to ground of 1~30 installed indicators nearby via short range radio frequency (it can adjust the channel automatically).At last, CSM-FTU-4 transmits the collected data to the communicate station via GPRS.

5.2. Structure

Overhead type data collecting communication terminal CSM-FTU4-I mainly consists of the chassis, the MPU (including an RF main node module, GPRS module, SIM card), RF module antenna, GPRS antenna, wide ranged temperature rechargeable batteries, solar panels.

Intelligent Overhead line short-circuit and ground fault indicatorIntelligent Overhead line short-circuit and ground fault indicatorIntelligent Overhead line short-circuit and ground fault indicator

5.3,Features

     (1) RF node parameters online adjustment

      It would be set before delivery, we don’t need to do the local settings online.

NOTE: There may be quite complicated of the technical parameters and to use the function of RF module, welcome to consult our technical staff.

     (2)Settings of GPRS parameters

     It would be set before delivery, we don’t need to do the local settings online.If you really need to change the settings, you can send text messages through authorized phone number, or via wired deb ing box.

The GPRS module of CSM-FTU4-I has been running online normally until the battery voltage is lower than 10.5 V. If the GPRS module power off, it can recover after receive the signal of short circuit or grounding from the indicators, or in 10 minutes after power on. Therefore, you should disconnect the solar panel, battery and control board for more than 10 seconds, and then re-Power-on after you change the GPRS parameters of the CSM-FTU4-I.

NOTE: GPRS parameter Settings have UART maintenance interface Settings (cable) and SMS Settings (the mobile phone must be the authorized number) two methods.

    (3) Parameters settings of overhead type data collecting communication terminal CSM-FTU4-I

    It would be set before delivery, we don’t need to do the local settings online. If you want to add more fault detection point or change the configuration table of the indicators, you can change the settings online.

Note: CSM - FTU4 –I parameter Settings have UART maintenance interface Settings (cable) and local RF wireless set up twomethods.

 

5. Workflow of the whole system

Intelligent Overhead line short-circuit and ground fault indicator

 

    The system is used for the less than 35kv voltage level transmission and distribution linesWhen the fault occurs on the power line, the indicators report the detect result to the communication terminal by transmitting via radio frequency. The damaged line information will send to the specified Internet address of the monitor system via GPRS from the communication terminal. The monitor system will analyze the data once it receive the signal from the communication terminal, then locate the fault section quickly. At last, the monitor system will alarm and it can select to send the information to the specified manager’s cell phone,

    Furthermore, the indicator can transmit the real-time status collect from the network to the monitor system.

 

6.Wireless remote real-time status monitoring system

Intelligent Overhead line short-circuit and ground fault indicator

 

 


Product Image

SNV-309 Remote Wireless Communication Terminal of Overhead Fault Indicator 1
Img 1
SNV-309 Remote Wireless Communication Terminal of Overhead Fault Indicator 2
Img 2
SNV-309 Remote Wireless Communication Terminal of Overhead Fault Indicator 3
Img 3
SNV-309 Remote Wireless Communication Terminal of Overhead Fault Indicator 4
Img 4
SNV-309 Remote Wireless Communication Terminal of Overhead Fault Indicator 5
Img 5

Send Inquiry to this Member

Zhuhai SNOVA Electric Technolagy(HongKong)CO.,LTD

Zhuzhou industrial park, Nanping, Xiangzhou District

Phone:
86-0756-8621065
Fax:
86-756-8618303
Contact:
BettyLucy (Sales manager)
Mobile:
13672655807

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Electric Control System Made In China Products

,  

Electric Control System China Suppliers and China Manufacturers