Laboratory instrument High quality Gas Chromatography
Product Description
Professional Gas Chromatograph for Ethylene Oxide
.Instruction
The special GC for ethylene oxide is your best choice in GC industry. It is equipped with the special chromatography column and headspace injector, which can analyze the ethylene oxide residue precisely.
Features
4.1 The detecting method is professional, innovative and adapted to the new international standards.
It Installs headspace injector of DK-300A to save the time for pre-processing of the injections, avoid the interference caused by organic solvents for analysis, and reduce the contamination of the column and inlet, reaching high analysis efficiency. The special chromatographic column successfully solves the overload problem of the columns and detectors. The changing of balance temperature, insulation temperature, injecting time and inflation pressure can be set.
4.2 The system is high precise and multi-functional, while its operation interface is simple and humanized.
4.2.1The use of new integrated digital electronic circuit has stable and reliable performance, and the temperature control can be precise to 0.01ºC.
4.2.2 It has functions of boot self-diagnosis, stopwatch(convenient to detect flow), timer operation, storage protection for power off, keyboard locking, anti-interference for power mutation, network data communication and remote control. All these functions are simple to operate.
4.3 Improved uniqueness and selectivity of the injector system with various injecting ways.
4.3.1 The unique inlet design solves the injecting discrimination, while the dual-column compensation function not only solve the problem of program drift by heating, and minus the effects of background noise, so as to get the minimum LOD.
4.3.2 Installed two kinds of injectors: packed column injector, split/splitless capillary injector(with the function of diaphragm cleaning).
4.4 Good stability and high sensitivity of the detector and its perfect supporting facilities can satisfy your various detection requirements.
It is convenient and time-saving, while the injectors can get high sensitivity, precise results and less error by using FID, headspace injecting method and the special chromatographic column for ethylene oxide.
4.5 Improved column designation for precisely controlling the programmed heating and furnace temperature, with the features of stability, balance and time-saving.
4.5.1 Increased column volume, and the intelligent backdoor system largely shortens the time for detector to keep stable and balance after the programmed heating/cooling.
4.5.2 Heating furnace temperature ramp range: environmental temperature +5ºC~420ºC.
4.5.3 7 steps programmed heating and the heating rate is 0.1~120ºC/min.
4.5.4 You can re-calibrate the furnace temperature, and set the maximum temperature within 420ºC according to your needs for the balance time of the heating furnace temperature.
.Parameters
Column oven |
Furnace dimensions |
28 x 30 x 18cm |
Temperature range |
Room temperature +5~420ºC |
Temperature setting |
1˚C, programmed heating rate 0.1˚C |
Maximum heating speed |
120ºC/min |
Temperature stability |
it will be 0.01˚C, when the environmental temperature changes 1˚C. |
Programmed heating |
7 steps |
Programmed heating rate |
0.1-120ºC/min(increment of 0.1ºC) |
Column loss can be compensated (dual channel column) |
FID |
Maximum operating temperature |
400ºC |
LOD |
≤5 x 10-12g/s[n-C16] |
Drift |
≤5 x 10-13A/min |
Noise |
≤2 x 10-15A |
Linear dynamic range |
≥107 |
.Application fields
It is widely used in the fields of petroleum, chemical, food, pharmaceutical, environmental protection, disease control, safety supervision, water, electricity, metallurgy, scientific research and QC.