1.1 Introduction
The Yacer HDLC-TCMS protocol converter, provides dual RS-485 synchronous & asynchronous serial ports and two expansion interfaces, with support for the conversion between synchronous HDLC and asynchronous UART. Optional dual 100M Ethernet interfaces, to achieve the protocol conversion between the serial port and the Ethernet interface.
Industrial wide temperature, complete isolation protection measures, applicable for the train communication network.
1.2 Applications
1.3 Features
1.4 Basic Function Blocks
The basic function blocks are shown in the drawing below:
1.5 Technical Specifications
RS-485 Interfaces S1, S2 |
|
Connector |
1 x male D-Sub 9 (X20) + 1 x female D-Sub 9 (X21) |
Interface type |
RS-485 half-duplex serial port with isolation |
Working mode |
Synchronous HDLC, Asynchronous UART |
Encoding format |
NRZI, Manchester, Differential Manchester, DBPL(Differential Bi-Phase Level) |
Baud rate |
Synchronous ≤ 10 Mbps Asynchronous ≤ 3 Mbps |
Isolation protection |
2.5 kVrms |
Expansion Interface S3 |
|
Connector |
1 x male D-Sub9 (X3) |
Optional interface type (One out of three) |
RS-232 full-duplex serial port RS-422 full-duplex serial port with isolation RS-485 half-duplex serial port with isolation |
Working mode |
Synchronous HDLC, Asynchronous UART |
Encoding format |
NRZI, DBPL, Manchester, differential Manchester |
Baud rate |
Synchronous ≤ 10 Mbps Asynchronous ≤ 3 Mbps |
Isolation protection |
2.5 kVrms |
Expansion Interface S4 |
|
Connector |
1 x male D-Sub9 (X4) |
Optional interface type (One out of three) |
CAN bus isolation interface (CAN 2.0A, CAN2.0B, ISO 11898) RS-422 full-duplex serial port with isolation RS-485 half-duplex serial port with isolation |
Working mode |
Synchronous HDLC, Asynchronous UART |
Encoding format |
NRZI, DBPL, Manchester, differential Manchester |
Baud rate |
Serial port: Synchronous ≤ 10 Mbps, Asynchronous ≤ 3 Mbps CAN: 50 Kbps ~ 1 Mbps |
Isolation protection |
2.5 kVrms |
Ethernet Interfaces ETH1, ETH2 |
|
Connector |
2 x M12 with D-coding |
Function |
Support for the Ethernet switching, VLAN and dual-IP functions |
Rate |
10/100 Mbps, Auto MDI/MDI-X |
Network protocol |
TCP/IP |
Programming interface |
UDP Server, UDP Client
|
Isolation protection |
1.5 kVrms |
Configuration Management |
|
Configuration tool |
yacer-DMS configuration management software |
Configuration interface |
Ethernet Interface |
Power Requirements |
|
Power Supply |
LV: Nominal 24V, range 9 ~ 36 VDC MV: Nominal 36V, 48V, range 18 ~ 75 VDC HV: Nominal 72V, 96V, 110V, range 40 ~ 160 VDC |
Isolation protection |
> 1.5 kV, support for the anti-reverse protection |
Power consumption |
< 3 W |
Power interface |
3 pin connector with 5mm pitch (Phoenix Contact MSTB 2,5 / 3-GF or equivalent) |
Mechanical Characteristics |
|
Dimensions |
HxWxD: 124 mm x 36 mm x 104 mm |
Weight |
500g |
Operating Environment |
|
Operating temperature |
-40 ~ +75℃ |
Storage temperature |
-40 ~ +85℃ |
Operating humidity |
5 ~ 95% RH (no condensation) |
1.6 Order Information
HDLC-TCMS |
- |
4 |
3 |
5 |
- |
LV |
400 series products: Dual 100M Ethernet Dual RS-485 serial ports |
|
|
|
|
||
S3 expansion interface: |
|
|
|
|
||
|
0 |
|
|
|
||
|
3 |
|
|
|
||
|
4 |
|
|
|
||
|
5 |
|
|
|
||
S4 expansion interface: |
|
|
|
|||
|
0 |
|
|
|||
|
4 |
|
|
|||
|
5 |
|
|
|||
|
6 |
|
|
|||
Supply voltage range: |
|
|
||||
|
LV |
|||||
|
MV |
|||||
|
HV |