Model: | Prime1 |
---|---|
Brand: | Clairair |
Origin: | Made In United Kingdom |
Category: | Electronics & Electricity / Transducer |
Label: | Prime1 , CO2 gas sensor , IR gas sensor |
Price: |
US $230
/ pc
|
Min. Order: | 1 pc |
Last Online:08 Jul, 2017 |
High Resolution Infrared Methane CH4 Sensor Prime1 0-100% vol
Features
• High Resolution of 0.01%vol for 0 - 10% vol and 0.1% vol for 10 - 100% vol
• Operates independent of supply polarity
• Pellistor mimic Bridge or linear voltage output
• Operating voltage range 3.0V – 5.0V
• Operating current 80mA typical
• Latest technology MEMS detectors
• Default range: High resolution 0-100%volume methane
• All metal construction with isolated housing
• Small internal volume
• Flexible electronic configuration access
• User calibration also enabled by hardware connections
• Wide operating temperature range
• Fast response
• Immunity from ‘poisoning’
Application
Coal mine
Oil field
Biogas plants
Description and Operation
The Prime1 sensor uses the non-dispersive infrared method to detect the presence of hydrocarbon gases.
The sensor contains an infrared radiation source, a dual element custom infrared detector,a unique optical waveguide into which gas diffuses and internal ARM7 core microprocessor based electronics to provide a voltage output which is independent of the power supply polarity.
The sensors can be configured to provide a pellistor format output, typically mid supply at zero with the voltage output increasing with respect to the detector pin by 100mV at range,or a linear voltage output, typically 0.4V – 2.0V over range with respect to the negative supply pin.
In addition, the output can be read and the internal configuration can be accessed by a serial communications link.
The communication link contacts are pads in the 3 pin version Prime1 and pins in the 5 pin version Prime1.
The internal electronics perform all the functions of driving the optical parts of the sensor, extracting the detectorsignals, converting the signals to a concentration, applying temperature compensation and scaling the output.
When in a pellistor configuration, the Prime1 can replace catalytic sensors in existing circuitry subject to thepower supply requirements. External components will be required to meet the power supply requirement when a Prime1 is used in constant current pellistor circuitry.
The Prime1 is not currently Ex approved so should behoused in a suitable Ex enclosure when used in Hazardous areas