Model: | - |
---|---|
Brand: | kacise |
Origin: | - |
Category: | Electronics & Electricity / Electronic Instrument / Electronic Measurment Apparatus |
Label: | ultrasonic sensor , sensor |
Price: |
US $80
/ piece
|
Min. Order: | 1 piece |
Last Online:22 Sep, 2017 |
Brief introduction
This sensor provides very short to long-range detection and ranging, in a compact, robust PVC or stainless steel housing, designed to meet IP67 water intrusion. The power 9.0V-28V operation detects objects from 0.1meters to 10meters and provides sonar range information from 0.25meters out to 10meters out with 0.001meters or 0.01meters resolution. The interface output formats included are pulse width output, analog voltage output, NPN/PNP output and serial digital output.
Features
. Designed for outdoor or indoor distance and level measurement.
. High sensitivity
. Readings can occur up to every 33mS(30Hz) within 3meters or occur up to every 80ms(12.5Hz) within 10meters.
. Free run operation can continually measure and output ranger information.
. 9V-28V supply with very low average current draw.
. Multi-kind output type such as analog (4-20mA, 0/1-5V, 0/1-10V), RS485.
. Sensor operates at 40 KHz, 112 KHz, 175 KHz, 300 KHz, 1 MHz
GXUS-M56
Range |
50...500mm; 100...1000mm; 200...3000mm; 300...5000mm; 500...6000mm |
Resolution |
3mm or 0.1%(which is bigger) |
Response time |
< 200ms |
Display |
LED |
Emission angle |
20° |
Analog output |
4~20mA/500Ω LOADING |
Switch output |
RELAY DC 30V/ 5A , PNP/NPN(OPTIONAL) |
RS232/485 |
MODBUS protocol or customized protocol (optional) |
Power supply |
Standard 24VDC (±15%) |
Ambient temperature |
-20~+60°C |
Protection Class |
IP65 (IP66 is selectable) |
Installation |
M56*2 |
GXUS-M18,GXUS-M30
Sensing range |
70 ... 1000 mm; 120...2000mm; 200...3000mm |
Standard target plate |
100 mm x 100 mm |
Transducer frequency |
approx.255 kHz |
Response delay |
approx.125 ms |
LED blue |
Power on |
LED yellow |
solid: object in the evaluation range |
flashing: program function, object detected |
|
LED red |
solid: Error |
flashing: program function, no object detected |
Operating voltage UB |
10 ... 30 V DC , ripple 10 %SS |
No-load supply current I0 |
≤ 45 mA |
Output type |
1 analog output 0-10V or 4…20mA. |
Resolution |
0.11 mm at max. sensing range |
Deviation of the characteristic curve |
± 1 % of full-scale value |
Repeat accuracy |
± 0.1 % of full-scale value |
Load impedance |
> 1kOhm |
Temperature influence |
± 1.5 % of full-scale value |
Ambient temperature |
-25 ... 70 °C (-13 ... 158 °F) |
Storage temperature |
-40 ... 85 °C (-40 ... 185 °F) |
Connection type |
Device connector M12 x 1 , 4-pin |
Protection degree |
IP65 (IP66 selectable) |
Material |
Housing: nickel plated brass or stainless steel or plastic |
Transducer: epoxy resin/hollow glass sphere mixture; polyurethane foam |