Model: | Yxk-2000ga |
---|---|
Brand: | MEDECO MEDICAL |
Origin: | Made In China |
Category: | Industrial Supplies / Other Industrial Supplies |
Label: | : Therapy Equipment , Infant Incubator |
Price: |
US $3000
/ pc
|
Min. Order: | 1 pc |
Last Online:17 Sep, 2020 |
Model | YXK-2000G | YXK-2000GA | 8502 | YXK-5GB | YXK-6G |
Power standard | 220V/50Hz | 220V/50Hz | 220V/50Hz | 220V/50Hz | 220V/50Hz |
Power Consumption | ≤450VA | ≤450VA | ≤650VA | ≤320VA | ≤320VA |
Environment Temperature | 20-30º C | 20-30º C | 20-30º C | 20-30º C | 20-30º C |
Temperature display range | 25-45º C | 25-45º C | 25-45º C | 25-45º C | 25-45º C |
Temperature control range | 25-37º C | 25-37º C | 25-37º C | 25-37º C | 25-37º C |
The control range of the skin temperature | 25-37º C | 25-37º C | 25-37º C | 25-37º C | 25-37º C |
>37º C High temperature control range | 37.1-39º C | 37.1-39º C | 37.1-39º C | 37.1-39º C | 37.1-39º C |
Temperature fluctuation range | <0.5 º C | <0.5 º C | <0.5 º C | <0.5 º C | <0.5º C |
Bed surface temperature Error | <1.5º C | <1.5º C | <1.5º C | <1.5º C | <1.5º C |
Humidity display range | 0-90%RH | 0-90%RH | 0-90%RH | - | - |
Humidity display accuracy | +-10%RH | +-10%RH | +-10%RH | - |
- |
mermaid1{at}medeco-medical.com
Infant Incubtor YXK-2000GA
We designed the YXK-2000GA unit with advanced thermoregulation system for neonate patient for best care, and the servo-controlled humidifier supply the comfortable air inside of incubator with air low velocity. The proportional control provide the patients' humidity air need when and where. The versatile design of double wall prevents the evaporative heat loss common in seal surroundings gets adequately cared.
Servo-controlled humidification system maintains the relative humidity at a constant level in the incubator
Ultrasonic and low temperture nebulized humidification protects neonate from bacterias pollution
Microprocessor servo-controller ensures a precise and reliable temperature control
Set temperature, monitored air temperature and baby skin temperature and heating power are distinguished in display
Set and monitored humidity concentration are displayed separately
>37ºC override temperature function
Self-checking function for safety affirmative
Audible and visible alarm indications for multiple failures with 3 priorities
Chord alarm notes nurse farther than 8meters, but leaves asleep baby uninterrupted
Aluminous framework for constant temperature keeping
Continuous adjustment of mattress inclination up to 10º
Drawer-type water reservoir is easily removable for cleaning and disinfection
Nature air cirulation system
Cupboard cabinet
RS-232 Connector
Application
The optical design of incubator with servo-controlled humidity and temperature keeps the baby in a stable environment virtually in any NICU for fragile neonate.
Widely applicable in all hospitals and clinics and optimize for preterm births or for some ill full-term babies.
Optional Accessories
l X-ray cassette
l Side door, front-rear door
l Vertical height adjustable
l Infant phototherapy unit(LED light or OSRAM tubes)
Model | YXK-2000G | YXK-2000GA | 8502 | YXK-5GB | YXK-6G |
Power standard | 220V/50Hz | 220V/50Hz | 220V/50Hz | 220V/50Hz | 220V/50Hz |
Power Consumption | ≤450VA | ≤450VA | ≤650VA | ≤320VA | ≤320VA |
Environment Temperature | 20-30º C | 20-30º C | 20-30º C | 20-30º C | 20-30º C |
Temperature display range | 25-45º C | 25-45º C | 25-45º C | 25-45º C | 25-45º C |
Temperature control range | 25-37º C | 25-37º C | 25-37º C | 25-37º C | 25-37º C |
The control range of the skin temperature | 25-37º C | 25-37º C | 25-37º C | 25-37º C | 25-37º C |
>37º C High temperature control range | 37.1-39º C | 37.1-39º C | 37.1-39º C | 37.1-39º C | 37.1-39º C |
Temperature fluctuation range | <0.5 º C | <0.5 º C | <0.5 º C | <0.5 º C | <0.5º C |
Bed surface temperature Error | <1.5º C | <1.5º C | <1.5º C | <1.5º C | <1.5º C |
Humidity display range | 0-90%RH | 0-90%RH | 0-90%RH | - | - |
Humidity display accuracy | +-10%RH | +-10%RH | +-10%RH | - | - |