Model: | GDGS |
---|---|
Brand: | Gold |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Instrument / Analysis Instrument |
Label: | Tan Delta Testing , Dielectric Loss Test , Power Factor Tester |
Price: |
US $6
/ pc
|
Min. Order: | 1 pc |
Last Online:26 Mar, 2018 |
Introduction:
Characteristics:
Simple operation, the instrument is equipped with a high-end full touch LCD screen, super touch interface, each process is very clear, the operator does not need additional professional training can be used. Click on it to complete the whole process of measurement, is a very ideal intelligent dielectric loss measurement equipment.
The instrument is equipped with a calendar chip and large capacity memory, the test results can be stored in chronological order, at any time to view the history, and can print output.
The instrument can use high pressure, high voltage, standard, standard, positive connection method and reverse connection method, self excitation method and other methods can do testing; high voltage in standard high voltage conditions (greater than 10kV) dielectric loss.
The instrument can also test the full sealed CVT (capacitor voltage transformer) C1, C2 dielectric loss and capacitance, to achieve the C1, C2 simultaneous test. The instrument can also test the CVT ratio and voltage angle difference.
The instrument can accurately measure the dielectric loss and capacitance of CVT without dismantling the CVT high voltage lead.
The instrument can be used to measure the dielectric loss and capacitance value of C0 on the upper end of CVT.
The inverter and sampling circuit of the instrument are all controlled by digital, and the output voltage is adjustable continuously.
The instrument has many protection measures, such as input voltage fluctuation, output short circuit, over voltage, over current and temperature. The instrument also has the grounding detection function to ensure that no grounding equipment is not allowed to boost.
Parameters:
1 |
Use conditions |
-15℃~40℃ |
RH<80% |
|||
2 |
Anti-interference |
Frequency conversion |
||||
3 |
Power |
AC 220V±10% |
Allowable generator |
|||
4 |
High output |
0.5KV~10KV/12KV |
Every 0.1kV |
|||
Precision |
2% |
|||||
Maximum current |
200mA |
|||||
Capacity |
2000VA |
|||||
5 |
Self-excited power |
AC 0V~50V/15A |
45HZ/55HZ 47.5HZ/52.5HZ 55HZ/65HZ 57.5HZ/62.5HZ Automatic double frequency |
|||
6 |
Resolving power |
tgδ: 0.001% |
Cx: 0.001pF |
|||
7 |
Precision |
tgδ:±(Reading*1.0%+0.040%) |
||||
C x :±(Reading*1.0%+1.00PF) |
||||||
8 |
measuring range |
tgδ |
Unlimited |
|||
C x |
15pF < Cx < 300nF |
|||||
|
10KV |
Cx < 60 nF |
||||
|
5KV |
Cx < 150 nF |
||||
|
1KV |
Cx < 300 nF |
||||
CVT test |
Cx < 300 nF |
|||||
9 |
CVT range |
10~10000 |
||||
accuracy |
0.1% |
|||||
Resolving power |
0.01 |
|||||
10 |
Exterior dimension |
350(L)*270(W)*270(H) |
||||
11 |
Memory size |
The 200 group supports U disk data storage |
||||
12 |
Weight |
28 Kg |