Model: | MTS-100 |
---|---|
Brand: | Kongter |
Origin: | - |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | meter test system , power meter test |
Price: |
-
|
Min. Order: | 1 pc |
Last Online:05 May, 2018 |
Phase: 3
Accuracy class: 0.05 or 0.1
AC voltage output: 0-792V
AC current output: 0-120A
This Meter Test System features state-of-art designing with high accuracy. It is composed of high accurate (class 0.05% or 0.1%) standard reference meter and power source (up to 120A). This system is particularly designed with modular structure for calibration and test of different single phase/3 phase electronic/inductive active and reactive energy meters.
Main function:
Main features:
Order Info
MTS-100 contains 2 models with different accuracy below:
MTS-100C: Accuracy Class 0.05
MTS-100B: Accuracy Class 0.1
Technical Specification
AC Voltage output:
Range: 100V, 220V, 380V;
Adjusting range: (0~120) %RG, RG refers to range;
Adjusting resolution: 0.01%RG, 0.1%RG, 1%RG, or 10% RG;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1);
Distortion: ≤0.2% (Non capacitive load);
Max output load: 20VA each phase;
Accuracy: 0.05%RG (Class 0.05), 0.1%RG (Class 0.1);
AC Current output:
Range: 0.05A, 0.2A, 1A, 5A, 20A, 100A;
Adjusting range: (0~120) %RG, RG refers to range, similarly hereafter;
Adjusting resolution: 0.01%RG, 0.1%RG, 1%RG, or 10% RG;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Distortion: ≤0.2% (Non capacitive load);
Max output load: 120VA (100A range)
Accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)
Power output
Power output stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Active/reactive power measurement accuracy: 0.05%RG;
Phase output
Output adjusting range: 0°~360°;
Output adjusting resolution: 10°, 1°, 0.1°, or 0.01°;
Resolution: 0.01°;
Measurement accuracy: 0.05°.
Power factor output:
Adjusting range: -1 ~ 0 ~ +1;
Measuring resolution: 0.0001;
Measurement accuracy: 0.0005
Frequency output
Adjusting range: 40Hz ~70Hz;
Output adjusting resolution: 1Hz, 0.1Hz, 0.01Hz, or 0.001Hz;
Resolution: 0.001Hz;
Accuracy: 0.002 Hz.
Harmonic setting
Harmonic order: 2nd ~63rd
Harmonic amplitude: 0~40%
Harmonic angle: 0°~359.99°
Harmonic set error: 2~31times: ≤±0.1%, 32~63 times: ≤±0.2%;
Energy error measurement:
Active energy basic error limit:
±0.05%RD (Voltage 15V~660V, Current 0.02A~120A, PF≥0.5);
±0.1%RD (Voltage 15V~660V, Current 0.01A~0.02A, PF=1);
Reactive energy basic error limit:
±0.1%RD (Voltage 15V~660V, Current 0.02A~120A, PF≥0.5);
±0.2%RD (Voltage 15V~660V, Current 0.01A~0.02A, PF=1);
Energy pulse input
Input pulse: 3 channels active, 3 channels reactive
Other parameters:
Power supply: 90-265VAC/DC
Power frequency: 50Hz~60Hz
Power consumption: 50VA~1000VA
Environment condition: 20℃~30℃,Humidity: RH≤85%
Storage environment: -20℃~50℃
Size: 600mm(L)× 440mm(W)× 266mm(H)
Weight: 35kg