Model: | SRM-362 |
---|---|
Brand: | Kongter |
Origin: | - |
Category: | Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument |
Label: | meter , standard meter , power meter |
Price: |
-
|
Min. Order: | 1 pc |
Last Online:05 May, 2018 |
SRM-362 High Accuracy Multifunction Standard Meter
Phase: 3
Accuracy: Class 0.05
AC voltage measurement: 0-660V
AC current measurement: 0-120A
With high accuracy and reliability, SRM-362 is used as standard reference meter to test electric meter, energy meter and all kinds of AC electric quantity. These make it widely applied in measurement center, power supply corporations, power stations, quality control departments, research institutions, universities, manufacturers of electric meters, etc.
Main functions:
Main features:
Type:
SRM-362 contains 2 models with different accuracy below:
SRM-362C High Accuracy Multifunction Standard Meter, Class 0.05
SRM-362B High Accuracy Multifunction Standard Meter, Class 0.1
Technical Specification
AC Voltage Measurement
Range: 75mV, 750mV, 7.5V, 30V, 100V, 300V, 660V automatically switch
Stability: ≤100ppm/year
Measurement accuracy: 0.05%RG
AC Current Measurement
Range: 500μA, 2mA, 10mA, 50mA, 200mA, 500mA, 2A, 5A, 10A, 30A, 120A automatically switch
Stability: ≤100ppm/year
Measurement accuracy: 0.05%RG
Power Measurement
Active/reactive power measurement accuracy: 0.05%RG
Phase angle measurement
Measuring range: 0°~360°
Resolution: 0.001°
Measurement accuracy: 0.05°
Frequency measurement
Measuring range: 40Hz ~70Hz
Resolution: 0.001Hz
Accuracy: 0.002 Hz
Harmonic Voltage
Harmonic order: 2nd ~127th
Harmonic amplitude: 0~100%
Harmonic accuracy: when Uh≥1%Un, 5% Uh; when Uh<1%Un, 0.05% Un.
Harmonic Current
Harmonic order: 2nd ~127th
Harmonic amplitude: 0~100%
Harmonic accuracy: when Uh≥3%Un, 5% Uh; when Uh<3%Un, 0.15% Un
Energy error measurement:
Active energy basic error limit:
±0.05%RD (Voltage 15V~660V, Current 0.05A~120A, PF≥0.5)
±0.1%RD (Voltage 15V~660V, Current 0.02A~0.05A, PF=1)
Reactive energy basic error limit:
±0.1%RD (Voltage 15V~660V, Current 0.05A~120A, PF≥0.5)
±0.2%RD (Voltage 15V~660V, Current 0.02A~0.05A, PF=1)
Energy pulse
Energy pulse output:
Pulse constant setting range: (1~599999999) r/kWh (r/kvarh)
Max. output frequency: 10KHZ
Energy pulse input:
Pulse constant setting range: (1~599999999) r/kWh (r/kvarh)
Calibration pulse setting range: 1~999999
Max. input frequency: 10KHZ
Other parameters:
Power supply: 90-265VAC/DC
Power frequency: 50Hz~60Hz
Power consumption: 100VA
Environment condition: 20℃~30℃,Humidity: RH≤85%
Storage environment: -20℃~50℃
Size: 400 (L)× 440(W)× 176mm(H)
Weight: 15kg