Home > Products > Electronics & Electricity > Electronic Instrument > Other Electronic Instrument

TEKTRONIX PROBE 1
  • TEKTRONIX PROBE 1

TEKTRONIX PROBE

Model:TEKTRONIX
Brand:TEK
Origin:-
Category:Electronics & Electricity / Electronic Instrument / Other Electronic Instrument
Label:TEKTRONIX PROBE , TEKTRONIX ACCESSORY , PROBE ACCESSORIES
Price: -
Min. Order:10 pc
Inquire Now

Member Information

Detail

TEK ELECTRONICS (HONGKONG) CO.,LTD

Biz MemberGuang Dong - China
Last Online:27 Jun, 2024

Product Description

IsoVu Isolated Probes  

IsoVu® probes are the right tool for today’s demanding power measurement challenges given their industry leading 1 GHz bandwidth, 160 dB or 100 Million to 1 common mode rejection, 60 kV common mode voltage, large ± 2500 V differential range and superior probe loading.Learn how you can use IsoVu technology to make impossible measurements such as high side Vgs.
 

Model Bandwidth Differential Voltage Common Mode Voltage Common Mode Rejection Ratio Fiber Cable Length  
TIVH02 200 MHz

± 2500 V

≤ 60 kV

DC: > 160 dB

100 MHz: 100 dB

200 MHz: 100 dB

3 meters

 

TIVH02L 200 MHz

± 2500 V

≤ 60 kV

DC: > 160 dB

100 MHz: 100 dB

200 MHz: 100 dB

10 meters

 

TIVH05 500 MHz ± 2500 V ≤ 60 kV

DC: > 160 dB

100 MHz: 100 dB

500 MHz: 80 dB

3 meters

 

TIVH05L 500 MHz ± 2500 V ≤ 60 kV

DC: > 160 dB

100 MHz: 100 dB

500 MHz: 80 dB

10 meters

 

TIVM1 1 GHz ± 50 V

≤ 60 kV

DC: > 160 dB

100 MHz: 120 dB

1 GHz: 80 dB

3 meters

 

TIVH08 800 MHz ± 2500 V ≤ 60 kV

DC: > 160 dB

100 MHz: 100 dB

800 MHz: 75 dB

3 meters

 

TIVM1L 1 GHz ± 50 V

≤ 60 kV

DC: > 160 dB

100 MHz: 120 dB

1 GHz: 80 dB

10 meters

 

TIVH08L 800 MHz ± 2500 V ≤ 60 kV

DC: > 160 dB

100 MHz: 100 dB

800 MHz: 75 dB

10 meters

 

 

High Bandwidth Optical Probes

The DPO7OE series optical probes with a DPO70000 real-time scope deliver the performance and advanced debug capabilities designers need to fully troubleshoot 400G PAM4 signals, up to 56 GBaud, and reduce time to market.

These probes can also be used as a conventional O/E with flat response filter for general laser signal acquisition up to their respective bandwidth of 33 GHz or 59 GHz.

Model Wavelength Response High-bandwidth DC Optical Noise NRZ / PAM2 and PAM4  
DPO7OE1

750nm - 1650nm

up to 33 GHz

6.6 uW rms (TekConnect / ATI)

up to 28 Gbaud

 
DPO7OE2

1200m - 1650nm

up to 59 GHz

10 uW rms (ATI)

up to 56 Gbaud

 

Power Rail Probes 

Optimized for power integrity measurements, these probes combine low noise contribution, DC offset up to 60 V, high bandwidth, low loading, and a wide range of connectivity alternatives.

 

Model Attenuation Bandwidth Dynamic Range DC Offset  
TPR1000

1.25x

1 GHz

±1 V

±60 V

 

TPR4000

1.25x

4 GHz

±1 V

±60 V

 


Current Probe

Tektronix current probe solutions offer:

  • The broadest range of AC/DC and AC-only current probes
  • Measurement accuracy from uAs to 2000 A
  • Best-in-class bandwidth up to 120 MHz
  • Best-in-class current clamp sensitivity down to 1 mA
  • The only products with 3rd Party Safety Certification (UL, CSA, ETL)
  • The only products with bare wire voltage ratings
  • Automatic readout and scaling when used with Tektronix oscilloscopes so you don’t have to convert volts to amps or manually set the scaling
         
         
           
           
           
           

Model                             Maximum Current                                                 Minimum Current          Bandwidth          Rise Time
A621                    RMS: 1000 A Peak: 2000 A                                                     10 mA                    50 kHz-
A622                    DC: 100 A  Max RMS: 71 A Peak Current: 100 A                    50mA                   100 kHz-
CT2                      Peak: 36 A Max RMS: 2.5 A continuous                          mA                      200 MHz            < 500 ps
CT1                    Peak: 12 A  Max RMS: 450 mA continuous                  200 μA                   1 GHz                 < 350 ps
CT6                    Peak: 6 A Max RMS: 120 mA continuous                               200 μA                 2 GHz                     < 200 ps

TRCP0300                   300A                                                                            250 mA                    30 kHz-

TCP305A       DC: 50 A Max RMS: 35.4 APeak Current: 50 A                             5 mA                     50 kHz-                   < 7 ns
P6021A        Max RMS: 10.6 A Peak Current: 250 A                                          10 mA                    60 MHz-                < 5.8 ns

TRCP3000                 3000 A                                                               500 mA                 16 MHz

TRCP0600                     600 A                                                                         500 mA                   30 MHz
P6022         Max RMS: 4 A Peak Current: 100 A                                               1 mA                      120 MHz-                < 2.9 ns
TCP312A  DC: 30 A Max RMS: 21.2 A Peak Current: 50 A                             1 mA                       100 MHz              < 3.5 ns
TCP202A  DC: 15 A Max RMS: 15 A Peak Current: 50 A                               10mA                      50MHz                 < 7 ns

TCPA400             (Probe Dependent)                                                                                          100 MHz             

         
TCP2020            20 A RMS, 100 A Peak Pulse                                           10 mA                  50 MHz                 ≤ 7ns          
           
           
TCPA300                                                                                                                             DC - 100 MHz                 

TCP0020         DC: 20 A Max RMS: 20 A Peak Current: 100 A                            10 mA                50 MHz                           < 7 ns 
TCP303           DC: 150 A Max RMS: 150 A Peak Current: 500 A                       5 mA                   15 MHz                           < 23 ns

TCP0030A     DC: 30 A Max RMS: 30 A Peak Current: 50 A                              1 mA                       120 MHz                      < 2.92 ns
TCP404XL     DC: 500 A Max RMS: 500 A Peak Current: 750 A                        1 A                               2 MHz                     < 175 ns
TCP0150        DC: 150 A Max RMS: 150 A Peak Current: 500 A                        5 mA                     20MHz                    < 17.5 ns
Differential Probe - High Voltage
A high voltage differential probe is used for measuring the voltage difference between two test points where neither test point is at ground.  High voltage differential probes from Tektronix can be used for signals up to 6000 V.  These probes are the best choice for making non-ground referenced, floating or isolated measurements in large part due to their common mode rejection capability. These products are designed, manufactured, and serviced by Tektronix.Tektronix High Voltage Differential Probe solutions offer:Best-in-class bandwidth and probe loadingThe only products with 3rd Party Safety Certification (UL, CSA, ETL)High and medium voltage products to support varying dynamic range and measurement resolution requirementsMost extensive set of probe accessories

         
MODEL             Attenuation               Bandwidth              Input Impedance                     Maximum Voltage          

P5200A           50X / 500X                       50 MHz                   10 MΩ || 2 pF                        500X:±1300 V 50X: ± 130 V
P5202A         20X / 200X                       100 MHz                  5 MΩ || 2 pF                         200X: ± 640 V  20X: ± 64 V
P5205A         50X / 500X                       100 MHz                 10 MΩ || 2 pF                        500X:  ± 1300 V  50X: ± 130 V

THDP0200   50X / 500X                       200 MHz                 10 MΩ || 2 pF                        500X: ± 1500 V  50X:  ± 150 V
TMDP0200   25X / 250X                       200 MHz                 5 MΩ || 2 pF                          250X: ± 750 V  25X: ± 75 V
P5210A        100X / 1000X               50 MHz                  40 MΩ || 2.5 pF                      1000X: ± 5600 V  100X: ± 560 V
THDP0100   100X / 1000X                  100 MHz                 40 MΩ || 2.5 pF                       1000X: ± 6000 V  100X: ± 600 V
TDP0500       5X / 50X                       500 MHz               1 MΩ || ≤ 1 pF                        50X:  ± 42 V   5X: ± 4.2 V
TDP1000     5X / 50X                             1 GHz                    1 MΩ || ≤ 1 pF                        50X:  ± 42 V  5X: ± 4.2 V
P6251          5X / 50X                              1 GHz                   1 MΩ || ≤ 1 pF                         50X:  ± 42 V  5X: ± 4.2 V

Differential Probe - Low Voltage
Differential signaling used in high speed serial standards requires very accurate characterization. The industry-leading bandwidth and signal fidelity found in a Tektronix low voltage differential probe ensures that you see every possible detail. Tektronix offers TriMode™ architecture which streamlines measurement acquisition by enabling you to make differential, single-ended, and common mode measurements with a single connection!
MODEL             Attenuation               Bandwidth                  Input Impedance                     Maximum Voltage

ADA400A               1 MHz                1 MΩ || ~ 55 pF                   100x, 10x, 1x, 0.1x
TDP1500               1.5 GHz             200 kΩ / ≤1 pF                     1X / 10X                               ±25 V (DC + pk AC)
P6247                    1 GHz               200 kΩ / < 1 pF                     1X, 10X                                ±25 V (DC + pk AC)

TDP3500               3.5 GHz               100 kΩ / ≤0.3 pF                  5X                                     ±15 V (DC + pk AC)

TDP4000              4 GHz              100 kΩ || ≤ 0.3 pF                      5X                                      ±15 V (DC + pk AC)

P7504                 4 GHz                         -                                       5X / 12.5X                              ±15 V (DC + pk AC)

P6248              1.5 GHz           200 kΩ / <1 pF                           1X, 10X                                ±25 V (DC + pk AC)
TDP7704         4 GHz    100kΩ (SIT) / 150kΩ (BRW) || 0.4 pF  4X / 10X                               ±12 V
TDP7706         6 GHz    100kΩ (SIT) / 150kΩ (BRW) || 0.4 pF  4X / 10X                                ±12 V
TDP7708         8 GHz    100kΩ (SIT) / 150kΩ (BRW) || 0.4 pF   4X / 10X                                 ±12 V
P7506              6 GHz                       100 kΩ                               5X / 12.5X                             ±15 V (DC + pk AC)
P7708              8 GHz    100kΩ (SIT) / 150kΩ (BRW) / 0.4 pF    4X / 10X                                ±12 V
P7508              8 GHz     100 kΩ                                                 5X / 12.5X                              ±15 V (DC + pk AC)
P7713                 13 GHz   100kΩ (SIT) / 150kΩ (BRW) / 0.4 pF   4X / 10X                                 ±12 V
P7513A              >13 GHz  100 kΩ5X /                                          12.5X                                      ±15 V (DC + pk AC)
P7716                16 GHz     100kΩ (SIT) / 150kΩ (BRW) / 0.4 pF  4X / 10X                                   ±12 V
P7516                16 GHz                           -                                     5X / 12.5X                                ±15 V (DC + pk AC)

P7625                25 GHz      50 Ω / 225 Ω0              25/0.5/1/2/4 (coax)1.25/2.5/5/10/20 (P76TA)   ±5 V (DC + pk AC)
P7720                20 GHz     100kΩ (SIT) / 150kΩ (BRW) / 0.4 pF   4X / 10X                                     ±12 V
P7520A          20 GHz                    -                                             5X / 12.5X                                   ±15 V (DC + pk AC)U

P7633               33 GHz     50 Ω / 225 Ω                0.25/0.5/1/2/4 (coax)1.25/2.5/5/10/20 (P76TA)    ±5 V (DC + pk AC)
Passive Probe
Passive voltage probes ship standard with most oscilloscopes and provide a low cost, general purpose probing solution. Generally, these probes lack the performance of an active voltage probe but provide the r edness and wide dynamic range suitable for visualizing signals over a broad range of applications. Tektronix has released a new class of passive probes that redefine performance in the passive probe product category.Tektronix new class of passive probe solutions offer:Best-in-class bandwidth up to 1 GHzBest-in-class input capacitance as low as 3.9 pF which minimizes probe loading effectsBest-in-class input capacitance which minimizes performance loss when long ground leads are attachedAutomated probe compensation eliminating the need for the compensation screwdriver
MODEL                Attenuation                  Bandwidth                          Input Impedance                              Maximum Voltage
 

 

TPP0051            10x                                     50 MHz                              10 MΩ || 12 pF                                  300 Vrms CAT II
TPP0100              10X                                    100 MHz                             10 MΩ || 12 pF                                  300 Vrms CAT II
TPP0101              10X                                   100 MHz                               10 MΩ || 12 pF                                  300 Vrms CAT II
TPP0200              10X                                   200 MHz                               10 MΩ || 12 pF                                   300 Vrms CAT II
TPP0201              10X                                   200 MHz                               10 MΩ || 12 pF                                   300 Vrms CAT II
P2220               1X / 10X               10X:200 MHz 1X: 6 MHz   10X: 10MOhm|| 17pF,1X: 1MOhm|| 110pF 10X: 300 Vrms CAT II,1X: 150 Vrms CAT II

P2221              1X / 10X                10X: 200 MHz1X: 6 MHz    10X: 10 MΩ || 110 pF 1X:  1 MΩ || 17 pF     10X: 300 Vrms CAT II1X: 150 Vrms CAT II
P6101B                  1X                         15 MHz                                              1 MΩ || 100 pF                                    300 Vrms CAT II
P3010                10X                           100 MHz                                             10 MΩ || 13 pF                                    300 Vrms CAT II
TPP0250        10X                            250 MHz                                          10 MΩ || 3.9 pF                                      300 Vrms CAT II
TPP0500B     10X                             500 MHz                                          10 MΩ || 3.9 pF                                        300 Vrms CAT

TPP0502       2X                               500 MHz                                           2 MΩ || 12.7 pF                                       300 Vrms CAT II
P6139B        10X                              500 MHz                                           10 MΩ || 8 pF                                           300 Vrms CAT II
P5050B        10X                              500 MHz                                          10 MΩ || 11 pF                                           300 Vrms CAT II
TPP1000      10X                             1 GHz                                               10 MΩ || 3.9 pF                                           300 Vrms CAT II

     
         
           
           
           
             
           
High Voltage Probe - Single Ended
A high voltage single-ended probe is typically used for measuring ground referenced signals up to 40 kV. However, some single-ended probes are designed for instruments with isolated or floating inputs for measurements that are not ground referenced. Users should select probes with a low input capacitance specification (< 4 pF) to minimize the probe’s loading effect on the circuit because a probe with lower input capacitance will offer higher input impedance at higher frequencies.Tektronix High Voltage Probe solutions offer:Best-in-class bandwidth up to 800 MHzBest-in-class probe loading with input capacitance as low as 1.8 pFThe only products with 3rd Party Safety Certification (UL, CSA, ETL)Most extensive set of probe accessories
MODEL                  Bandwidth                          Input Impedance                              Maximum Voltage
         

P5122                  200 MHz                              100 MΩ || 4 pF                       RMS: 1000 V CAT II

P5100A              500 MHz                                  40 MΩ || 2.5 p                     Peak: 2.5 kV  RMS: 1000 V CAT II
P5150               500 MHz                           40 MΩ || 3.8 pF                    Peak: 2.5 kVRMS: 1000 V CAT II

TPP0850          800 MHz                            40 MΩ || 1.8 pF                     Peak: 2.5 kV RMS: 1000 V CAT II
P6015A           75 MHz                               100 MΩ || 3 pF                                     20 kV

Low Voltage Probe - Single Ended
A low voltage single-ended probe is typically used for measuring high-speed, ground referenced signals up to 12 V. These low voltage probes are the best choice for making measurements on high impedance, high frequency circuit elements which require minimal probe loading.  Users should select probes with a low input capacitance specification (~1 pF) to minimize the probe’s loading effect on the circuit.  A probe with lower input capacitance will offer higher input impedance at higher frequencies.Tektronix Low Voltage Single-ended Probe solutions offer:Bandwidths up to 4 GHz.Very high input impedance with low input capacitance (<1 pF)Most extensive set of probe accessories for optimum measurement performance

         
MODEL                Attenuation                  Bandwidth                          Input Impedance                              Maximum Voltage          
           
P6243                 10X                                   1 GHz                                   1 MΩ || ≤ 1 pF                                          ± 8 V
P6245                   10X                                 1.5 GHz                               1 MΩ || ≤ 1 pF                                      ± 8 V
         
           
TAP1500              10X                             1.5 GHz                           1MΩ || ≤ 1 pF                                   ± 8 V          
           
           
           

TAP2500               10X                             2.5 GHz                           40 kΩ || ≤ 0.8 pF                            ± 4 V

TAP3500               10X                                3.5 GHz                             40 kΩ || ≤ 0.8 pF                           ± 4 V

TAP4000               10X                              4 GHz                              40 kΩ || ≤ 0.8 pF                          ± 4 V

         
           

 P7240                      5X                                4 GHz                                 20 kΩ || ≤ 0.8 pF                        ± 2 V

Logic Analyzer Probe
Verification and debug of today's high speed, low voltage digital signals requires probing solutions that can accurately acquire from a wide variety of electronic designs and protect signal fidelity. Tektronix logic analyzer probes contain a variety of connectivity options that are engineered to ensure that signal acquisition is a true reflection of your design's performance. Compare and learn more about Tektronix logic analyzer probe solutions.

Model Connectivity Instrument Series  
P5910 Fits both 0.100 in. and 2 mm square pin configurations TLA6400

 

TLP058 FlexChannel (TM) input 5 Series MSO

 

P5934 Amp Mictor 34-channel connector TLA6400

 

P5960 D-Max® probing technology compression cLGA TLA6400

 

Low Bandwidth Optical Probes
Depend on Tektronix to provide you with performance you can count on, and industry-leading service and support.Broad Wavelength Response 500 to 950 nm or 1100 to 1700 nmHigh-bandwidth DC up to 1.2 GHzHigh Gain 1 V/mWLow Noise <11 pW/√HzProbe Connects to DPO7000*1 and DPO/DSA/MSO70000*2SeriesSONET/SDH and Fibre Channel Reference Receiver Performance

Model Bandwidth  
P6703B ≥1.2 GHz

 

P6701B ≥1.0 GHz

 

 


Advantages:HIGH QUALITY
Export Markets:WORLDWIDE
Payment method:T/T
Min Order:10
Standard Met:CE/UL

Product Image

TEKTRONIX PROBE 1
Img 1

Send Inquiry to this Member

TEK ELECTRONICS (HONGKONG) CO.,LTD

ROOM 509,5/F, International Commercial building Bao An Bei Road,LuoHu District ShenZhen CIty,GuangDong Province

Phone:
00-852-557-452-62
Fax:
86
Contact:
Tony (MD)
Mobile:
136-0304-2874

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Other Electronic Instrument Made In China Products

,  

Other Electronic Instrument China Suppliers and China Manufacturers