Home > Products > Electronics & Electricity > Optical Fiber, Cable & Wire > Electric Wire & Cable

500 KV XLPE Insulated Power Cable 1
  • 500 KV XLPE Insulated Power Cable 1

500 KV XLPE Insulated Power Cable

Model:-
Brand:huiyou
Origin:-
Category:Electronics & Electricity / Optical Fiber, Cable & Wire / Electric Wire & Cable
Label: -
Price: -
Min. Order:100 pc
Inquire Now

Member Information

Detail

Product Description

We produced according to National Standard of GB/T 22078.2-2008 of the People’s Republic of China.

 Range of application

It is suitable for single-core cable’s installation and operation under normal conditions of rated voltage 290/500 KV, but it is not suitable for cable in special use, such as submarine cable.

Characteristics of cable

●Rated voltage of cable is U0=290 KV、U=500 KV、Um=550 KV.

●The allowable maximum temperature of cable conductor is 90℃ when it runs in normal, and 250℃ when it short circuited (Longest time is 5 s).

●The allowable minimum bending radius is 20 times of cable outside diameter when installed. After installation  , the minimum bending radius is recommended for 15 times of cable outside diameter.

 Service environment( Place )

Lead sheath cable, is suitable for environment with more serious corrosion but no much nitric acid, acetic acid and organic matter ( Such as mud, coal and strong alkaline corrosion matter with technical force, stress and vibration etc.)

Aluminium sheath cable, is suitable for environment with minor corrosion and required to bear a certain mechanical force ( For example, connected with transformer directly and laying at bridge opening or in shaft etc.)

●Metal plastic compound sheath cable is suitable for general damp and warm place , no corrosion or light corrosion and no direct contact with water and bear not so much technical force , pulling force , stress and vibration.

PVC outer sheath cable is mainly used in cable line with general fire-proof requirement and insulation requirement for outer sheath.

PE outer sheath cable is mainly suitable for directly buried laying cable line with higher requirement on outer sheath insulation, low temperature environment under 20℃, or soaked place by chemical liquid and low toxicity requirement when cable burns, when PE outer sheath is used in tunnel or shaft , fire-control and flame-retardant measures should be adopted if necessary.

Model and Name of product

Model

 Name of cable

Copper core

YJLW02

XLPE insulated corrugated aluminium sheath or welding  aluminium sheath PVC sheath power cable

YJLW03

XLPE insulated corrugated aluminium sheath or welding aluminium sheath PE sheath power cable

YJLW02-Z

XLPE insulated corrugated aluminium sheath or welding aluminium sheath longitudinally water blocking PVC sheath power cable

YJLW03-Z

XLPE insulated corrugated  aluminium sheath or welding aluminium sheath longitudinally water blocking PE sheath power cable

YJQ02

XLPE insulated lead sheath PVC sheath power cable

YJQ03

XLPE insulated lead sheath PVC sheath power cable

YJQ02-Z

XLPE insulated lead sheath PVC sheath longitudinally water blocking power cable

YJQ03-Z

XLPE lead insulated lead sheath PV sheath longitudinally water blocking power cable

Conductor structure , specifications , insulation thickness

Specifications Conductorcross-section (mm2)

structure

Minimum number of single wire in conductor

Maximum of conductordirect-current resistance(Ω/km)

Insulation nominal thickness

800

Round conductor/Segmental conductor

53

0.0221

34

1000

Segmental conductor

170

0.0176

33

1200

Segmental conductor

170

0.0151

33

1400

Segmental conductor

170

0.0129

32

1600

Segmental conductor

170

0.0113

32

1800

Segmental conductor

265

0.0101

31

2000

Segmental conductor

265

0.0090

31

2200

Segmental conductor

265

0.0083

31

2500

Segmental conductor

265

0.0073

31

 

Representation method of product

●For example

A. Single-core copper conductor with rated voltage of 290/500 KV, nominal sectional area of 1200 mm2, so XLPE insulated corrugated aluminium sheath PVC sheath power cable will be represented as : YJLW02-290/500 KV - 1×1200 GB/T 22078.2-2008.

B. Single-core copper conductor with rated voltage of 290/500 KV , nominal sectional area of 2500 mm2, so XLPE insulated corrugated lead sheath PVC sheath longitudinally water blocking power cable  will be represented as : YJQ03-Z-290/500 KV- 1×2500 GB/T22078.2-2008.

 

More information:

http://www.newmadinaapparels.com

http://www.cncmachoem.com

http://www.cncmachiningworks.com

http://www.starindustrys.com


Payment Terms:T/T, L/C

Product Image

500 KV XLPE Insulated Power Cable 1
Img 1

Send Inquiry to this Member

Cangzhou Huiyou Cable Stock Co., Ltd

The New Huiyou Industry Zone, Hejian

Phone:
86-317-3812602
Fax:
Contact:
YANG SONG (CEO)
Mobile:
13363672662

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Electric Wire & Cable Made In China Products

,  

Electric Wire & Cable China Suppliers and China Manufacturers