Model: | - |
---|---|
Brand: | huiyou |
Origin: | - |
Category: | Electronics & Electricity / Optical Fiber, Cable & Wire / Electric Wire & Cable |
Label: | - |
Price: |
-
|
Min. Order: | 100 pc |
Last Online:29 Aug, 2019 |
We produced according to National Standard of GB/T 22078.2-2008 of the People’s Republic of China.
Range of application
It is suitable for single-core cable’s installation and operation under normal conditions of rated voltage 290/500 KV, but it is not suitable for cable in special use, such as submarine cable.
Characteristics of cable
●Rated voltage of cable is U0=290 KV、U=500 KV、Um=550 KV.
●The allowable maximum temperature of cable conductor is 90℃ when it runs in normal, and 250℃ when it short circuited (Longest time is 5 s).
●The allowable minimum bending radius is 20 times of cable outside diameter when installed. After installation , the minimum bending radius is recommended for 15 times of cable outside diameter.
Service environment( Place )
●Lead sheath cable, is suitable for environment with more serious corrosion but no much nitric acid, acetic acid and organic matter ( Such as mud, coal and strong alkaline corrosion matter with technical force, stress and vibration etc.)
●Aluminium sheath cable, is suitable for environment with minor corrosion and required to bear a certain mechanical force ( For example, connected with transformer directly and laying at bridge opening or in shaft etc.)
●Metal plastic compound sheath cable is suitable for general damp and warm place , no corrosion or light corrosion and no direct contact with water and bear not so much technical force , pulling force , stress and vibration.
●PVC outer sheath cable is mainly used in cable line with general fire-proof requirement and insulation requirement for outer sheath.
●PE outer sheath cable is mainly suitable for directly buried laying cable line with higher requirement on outer sheath insulation, low temperature environment under 20℃, or soaked place by chemical liquid and low toxicity requirement when cable burns, when PE outer sheath is used in tunnel or shaft , fire-control and flame-retardant measures should be adopted if necessary.
Model and Name of product
Model |
Name of cable |
Copper core |
|
YJLW02 |
XLPE insulated corrugated aluminium sheath or welding aluminium sheath PVC sheath power cable |
YJLW03 |
XLPE insulated corrugated aluminium sheath or welding aluminium sheath PE sheath power cable |
YJLW02-Z |
XLPE insulated corrugated aluminium sheath or welding aluminium sheath longitudinally water blocking PVC sheath power cable |
YJLW03-Z |
XLPE insulated corrugated aluminium sheath or welding aluminium sheath longitudinally water blocking PE sheath power cable |
YJQ02 |
XLPE insulated lead sheath PVC sheath power cable |
YJQ03 |
XLPE insulated lead sheath PVC sheath power cable |
YJQ02-Z |
XLPE insulated lead sheath PVC sheath longitudinally water blocking power cable |
YJQ03-Z |
XLPE lead insulated lead sheath PV sheath longitudinally water blocking power cable |
Conductor structure , specifications , insulation thickness
Specifications Conductorcross-section (mm2) |
structure |
Minimum number of single wire in conductor |
Maximum of conductordirect-current resistance(Ω/km) |
Insulation nominal thickness |
800 |
Round conductor/Segmental conductor |
53 |
0.0221 |
34 |
1000 |
Segmental conductor |
170 |
0.0176 |
33 |
1200 |
Segmental conductor |
170 |
0.0151 |
33 |
1400 |
Segmental conductor |
170 |
0.0129 |
32 |
1600 |
Segmental conductor |
170 |
0.0113 |
32 |
1800 |
Segmental conductor |
265 |
0.0101 |
31 |
2000 |
Segmental conductor |
265 |
0.0090 |
31 |
2200 |
Segmental conductor |
265 |
0.0083 |
31 |
2500 |
Segmental conductor |
265 |
0.0073 |
31 |
Representation method of product
●For example
A. Single-core copper conductor with rated voltage of 290/500 KV, nominal sectional area of 1200 mm2, so XLPE insulated corrugated aluminium sheath PVC sheath power cable will be represented as : YJLW02-290/500 KV - 1×1200 GB/T 22078.2-2008.
B. Single-core copper conductor with rated voltage of 290/500 KV , nominal sectional area of 2500 mm2, so XLPE insulated corrugated lead sheath PVC sheath longitudinally water blocking power cable will be represented as : YJQ03-Z-290/500 KV- 1×2500 GB/T22078.2-2008.
More information:
http://www.newmadinaapparels.com
Payment Terms: | T/T, L/C |
---|---|