Model: | CKT3554 |
---|---|
Brand: | CKT |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Instrument / Other Electronic Instrument |
Label: | battery tester , battery internal , battery meter |
Price: |
US $800
/ set
|
Min. Order: | 1 set |
Last Online:29 May, 2020 |
Repeated recharging of a secondary battery can lead to battery deterioration and increase its internal resistance. Problems can intensify when there is a short-circuit in the internal cell leading to voltage drop, overheating and complete battery malfunction. Worst of all, these problems can cause life-threatening fires and other accidents. Using the large current and anti-interference design, CKT3554 battery tester provides fast, complete and accurate diagnosis in internal resistance and voltage for backup UPS batteries and lead-acid batteries.
|
SPECIFICATIONS | |
CKT3554 Handheld Battery Meter | |
Parameters | ESR, DCV |
Accuracy | Resistance: 0.5%
Voltage: 0.02% |
Measurement Range | Resistance: 0.001mΩ~3.1Ω Voltage: 0.1mV~60V Temperature: -10°C to 60°C |
Signal Source | AC 1kHz, Test current: <150mA |
Range | Resistance: 3mΩ/30mΩ/300mΩ/3Ω
Voltage: 6V/60V |
Speed | 1 meas/sec (the average number optional) |
Display Max | Resistance: 3100, Voltage:6000 |
Max Resolution | Resistance: 0.001mW, Voltage: 0.1mV |
Adjustment | Short-circuit cear zero for all ranges |
Comparator | 200 sets of WARNING/FAIL/PASS, sorting |
Trigger | Internal/auto trigger |
Internal data storage | Store up to 2400 test data |
Interface | USB |
Others | Super anti-interference, can measure UPS battery on load
Provide function of battery status diagnose, directly indicate battery health |
GENERAL FEATURES | |
Power Supply | 12V/1700mAh lithium battery, AA (LR6) Alkaline Batteries x 8 |
Battery Parameters | 8.4v, Li, 2200mAh rechargeable battery |
Working Time | ≥8 hours |
Size | 208 mm (L) x120mm (W) x 52mm (D), without sleeve |
ORDERING INFORMATION | |
Accessories | Test probe, mini USB communication cable; zero board;
DC power adaptor; temperature probe; Li- battery; Kelvin test leads (optional) |