Model: | TS 32 |
---|---|
Brand: | Lad Companion |
Origin: | Made In China |
Category: | Industrial Supplies / Environment Protection Facilities / Other Environment Protection Facilities |
Label: | - |
Price: |
US $11800
/ pc
|
Min. Order: | 1 pc |
Last Online:20 Jul, 2023 |
Quick Details
Place of Origin:Guangdong, China
Brand Name:Lab companion
Model Number:TS32
Power:Electronic
Product name:Thermal Shock Test Chambers
Temperature range:-80~100℃
Function:temperature test machine
Power supply:AC380V 10% 50HZ
Type:Temperature Test Chamber R448A
Material:SUS304 Stainless Steel
Accuracy:0.01
Certificate:CE Certificate
Standard:IEC-60749-25
Warranty:12 Months
Supply Ability
Supply Ability:10 Set/Sets per Month
Packaging & Delivery
Packaging Details: plywood
Port: Shenzhen
Thermal Shock Test Chambers, Series TS
Lab Companion’s Thermal Shock Chamber is an effective tool in subjecting products to a thermal shock test. Thermal Shock Environmental Chambers have a product carrier basket that automatically transports a product under test between separately controlled temperature zones. With built-in viewing windows, users can easily observe the product as it’s transferred between different temperature zones. Thermal Shock Chambers come in a variety of performance configurations to meet specific testing needs and includes the intuitive Lab Companion Controller.
Three of the test chamber configurations include:
A Vertical Orientation Thermal Shock Chamber has two independently controlled hot and cold zones; one atop the other. A single product carrier moves between each zone, subjecting the product to dramatic changes in temperature. An advantage of the Vertical Orientation chamber is it uses less floor space, making it ideal for smaller labs.
A Horizontal Orientation Thermal Shock Chambers has three side-by-side independent zones: hot, ambient, and cold. The addition of the ambient zone allows for three zone testing, which is a requirement of some military standards. This unique and versatile chamber configuration can also be used for two zone tests. This is accomplished by programming the product carrier to automatically transfer the product from hot to cold, and back again, eliminating a dwell in the ambient zone.
A Double Duty Thermal Shock Chamber has a cold zone positioned between two hot zones, aligned vertically top and bottom. Products under test are placed in one of two product carriers and transferred between the zones producing severe thermal stress. At least one product carrier always occupies the cold zone. This design makes efficient use of the chamber cooling system, providing increased product testing throughput over standard thermal shock designs. Heaters are incorporated into the cold zone for defrost, allowing the zone to be operated as a temperature cycling chamber when it is not being used for thermal shock tests.
The innovative technology of our Lab Companion temperature shock test cabinets allow temperature changes up to 100 K/min. The most common national and international standards (DIN, IEC, MIL) are met. The compressed-air dryer system used as a standard allows up to 3000 test cycles without defrosting.
Basic Equipment:
Your benefits:
Test space capacity in litres:
Temperature range:
Design:
Control:
Multi-Touch-Display with integrated program controller
Test space:
stainless steel grade 1.4301
Refrigerants:
environmental friendly refrigerants
Options:
Type | TS 32 | TS 60 | TS 120 | TS 300 | |
---|---|---|---|---|---|
Test Space | litres | 32 | 60 | 120 | 300 |
Test Space Dimensions in mm | height, appr.
width, appr. depth, appr. |
300
360 300 |
370
380 430 |
410
470 650 |
610
770 650 |
Overall Dimensions in mm | height, appr.
width, appr. depth, appr. |
1820 (2415*)
820 1325 |
1820 (2415*)
880 1550 |
1820 (2525*)
940 2335 |
2450 (3200*)
2160 (2300**) 2200 |
Temperature Tests | |||||
Temperature Range in °C | hot chamber
cold chamber |
+50/+220
-80/+100 |
+50/+220
-80/+100 |
+50/+220
-80/+100 |
+50/+220
-80/+100 |
Adaption time of IC´s < 15 min in kg | 2,5 | 2,5 | 10,0 | 25,0 | |
Changing Time in sec. | < 10 | < 10 | < 10 | < 10 | |
Test Load in kg, max. | 10 | 22 | 50 | 110 | |
Temperature Fluctuation in K | temporally | ± 1 | ± 1 | ± 1 | ± 1 |
Nominal Voltage | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | 400 V +6% -10%, 3/N, 50 Hz | |
Nominal Power in kW | appr. | 9,7 | 9,7 | 19,0 | 33,0 |
Refrigeration Units | air cooled | air cooled | water cooled | water cooled | |
Weight Cabinet in kg | appr. | 650 | 700 | 950 | 2500 |
Noise Level in dB(A) | 58 | 58 | < 60 | < 68 | |
Entry Ports Ø in mm | 50 | 80 | 125 | 125 |
All figures are average values which have been obtained at a temperature of +25° C, without test specimens, without thermal load and without options.
* = height with spindle
** = width with spindle drive