Model: | GDVA-404/405 |
---|---|
Brand: | GOLD |
Origin: | Made In China |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | CT PT analyzer , CT PT characteristic , CT PT parameter anal |
Price: |
US $3500
/ pc
|
Min. Order: | 1 pc |
Last Online:22 Apr, 2021 |
Descriptions
The GOLD GDVA test set is a lightweight, robust, portable unit capable of testing both current and voltage transformers. At less than 15Kg the GDVA is a highly portable unit that also offers accuracy in testing. Capable of performing saturation, ratio, polarity, winding resistance, and insulation tests on current transformers, the GDVA can also be used for testing metering and protection class voltage/potential transformers.
The GDVA provides a microprocessor controlled variable voltage and current output along with precision instrumentation for automatically testing single and multi-ratio CT's and PT’s. The GDVA makes testing CT’s easy. It will directly connect to multi ratio CT’s and perform all tests – saturation, ratio and polarity, winding resistance, and insulation – on all taps with the push of a button and without changing leads. This greatly reduces testing time.
The GDVA can be controlled via its large, full color, high resolution, sunlight readable TFT LCD touch screen display. This interface allows the user to perform manual and automatic testing quickly and easily using the manual test screen, or by using ore-constructed test routines. The large color display also permits the user to easily read all pertinent data while the test is being performed and provides the ability to view the results when the test is complete.
Main test function
CT (protection, measurement) |
PT |
Volt-ampere characteristic (excitation characteristic) curve |
Volt-ampere characteristic (excitation characteristic) curve |
Automatically give the inflection point value |
Automatically give the inflection point value |
Automatically give 5% and 10% error curves |
Transformation ratio measurement |
Transformation ratio measurement |
Polarity judgment |
Polarity judgment |
Ratio measurement |
One flow test |
Angle difference measurement |
Ratio measurement |
AC withstand voltage test |
Angle difference measurement |
Secondary load test |
AC withstand voltage test |
Secondary winding test |
Secondary load test |
Iron core demagnetization |
Secondary winding test |
|
Iron core demagnetization |
|
Features
1) Able to test Protection CT’s, Measuring CT’s, TP class CT’s and inductive PT’s
2) Test excitation characteristic and error curve based on low-frequency measurement principle
3) Measure ratio, polarity, ratio error and phase displacement error based on voltage method
4) Adopt patented multifunctional rotary mouse to replace the keypad
5) Adopt 5.7 inches LCD screen for display
6) Adopt DSP, ARM and embedded LINUX operation system
7) Both local test and PC remote test available
8) Higher measurement accuracy: 0.05 %
9) Print test results directly by built-in thermal printer
10) Small and light weight for easy transport
CT/PT Analyzer Technical Index
1) Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
2) Power supply: AC220V±10%, 50/60Hz±10%
3) Voltage output: 0.1~180V (AC)
4) Current output: 0.001~5A(RMS)
5) Power output: 500VA
6) Maximum knee voltage measurement: 45KV
7) Current measurement:
Range: 0~10A (automatically change range in 0.1/0.4/2/10A)
Error: <±0.1%+0.01%FS
8) Voltage measurement:
Range: 0~200V (automatically change range in 1V/10V/70V/200V)
Error: < ±0.1%+0.01%FS
9) Turns ratio measurement:
Range:1~35000
1~2000 error<0.05%
2000~5000 error<0.1%
5000~35000 error<0.2%
10) Phase measurement: error: ±2min; resolution: 0.01min
11) Winding resistance measurement:
Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error: < 0.2%RDG+0.02%FS
Maximum resolution: 0.1mΩ
Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error: <0.2%RDG+0.02%FS
Maximum resolution: 0.001ohm
14)PT Secondary burden:
Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error :<0.2%RDG+0.02%FS
Maximum resolution: 0.1ohm
15)PT ratio measurement:
Range: 1~35000
1~5000 error<0.2%
5000~35000 error<0.5%
16) PT phase angle test: error < 9min
17) Memory capacity: >1000 groups test results
18)Working condition: temperature: -10℃~50℃; moist: ≤90%
19) Size: 485mm×356mm×183mm
20) Weight: <15kg