Model: | BW-HK002R |
---|---|
Brand: | - |
Origin: | Made In China |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | - |
Price: |
-
|
Min. Order: | 500 pc |
Last Online:20 Nov, 2021 |
CSA approval Constant Temperature Water Heater Control Board BW-HK002R
gas water heater control board Function description
1) It works with a display.
2) It works with a ventilator.
3) It works with a on-off valve, a proportional valve and a section valve.
4) It is with a buzzer.
5) It has AC ionization flame signal detection.
6) Status keeping function: If the nP menu was set as ON, after power on again, the system
will return to the last status before the power is cut off.
7) Flue pipe block-up protection.
8) Malfunction protection and warning function.
9) Compliance with Standard: BS EN298: 2012. ANSI Z21.20 -2014. CAN/CSA C22.2 No. 60730-2-5-2014.
More information you can click here
Main technical parameters |
|
Working voltage range |
90VAC ~ 120VAC |
Rated voltage |
120VAC 60Hz |
Power frequency |
50/60Hz±5% |
Rated frequency |
50Hz |
Dielectric strength(V/1min) |
1800V, 0.5mA, 3S |
Working ambient temperature |
-10℃~70℃ |
Ambient temperature |
-20℃~70℃ |
Life cycle |
≥50,000 times |
Temperature setting range |
35-65℃ |
High temperature protection |
when the output water temperature ≥85℃ for 3S |
Pre- cleaning time |
2S |
After cleaning time |
20s |
Start-up water flow |
≤3L/min |
Closing water flow |
≤2.5L/min |
Ignition time |
8±1S |
Cleaning time before 2nd ignition |
3S |
Max. allowable No. of ignition |
2 |
Valve moving pulse |
0.5±0.05S |
24V Valve open voltage |
≥24V |
24V Valve holding voltage |
≥8.5V |
Output voltage of switch power supply |
5VDC (with 300mA working current) |
30±1.5VDC(with 510mA working current) |
|
12±1VDC(with 110mA working current) |
|
Ion sensibility of flame detection |
≥5.1MΩ |
Temperature detection precision |
±2℃ |
Waiting time of reaching setted temperature |
≤35S |
Water temperature overshoot range |
±3℃ |
Timing tolerance |
±1 minutes |
Post-purge time |
20±2s |
Time to achieve safe shut down |
<1s |
Trial for ignition period |
7.5±1s |
Payment Terms: | FOB Shunde |
---|---|