Product Description
LME73.0000A2 automatic combustion, basic unit, intermittent, SA, for PME73.xxxA2, AC230V
LFL1... burner control device is specially designed for forced air burner control and monitoring. It can be used for direct ignition or medium and high power burners with ignition burners. Fuel gas is universal and can be used for fixed preheated air burners WLE according to DIN 4794 standard
The difference between 01 series and 02 series is: ① the safety time of ignition burner with ignition gas valve is different; ② the controller of high-power atmospheric combustion is LFL1.638; if the burner needs continuous operation control, ③ the safety time of burner with ignition gas valve is different.
After the allowed afterburning time of LFL1, the detection electrode and flame simulation test are immediately restored. The fuel valve that is not closed or not completely closed will lock the controller unit of the burner immediately after the allowed afterburning time. The detection electrode and flame simulation inspection only ends when the pre-purge time at the next burner start is completed- During each start-up of the burner, the correct action of the flame monitoring circuit is automatically checked- The controller contact used to release fuel shall be inspected within each post-purge time to ensure that the contact is not closed- A built-in fuse unit protects the contact of the controller from overload.
T1 Pre-purge time TAS safety ignition time TAS safety ignition time t3 pre-ignition time t3 pre-ignition time, Terminal 17 release voltage t4 starts from t2 to terminal 19 release voltage t5 ends from t4 to terminal 20 release voltage t6 post-purge time t7 start command to terminal 7 release voltage t9 safety time t10 start to air pressure control start t11 full open time t12 full close time t13 post-purge time t16 start command to full open command interval t20 stop without post-purge, To next start interval
DANFOSS nozzle/nozzle, HAGO nozzle/nozzle, STEINEN nozzle/nozzle. The atomization shape is solid (S), semi-solid (B), and hollow (H). The spray angle is 45 degrees, 60 degrees, 80 degrees, etc. Weisaupt models W50-110, W50-125, W50-140, W50-160, W50-180, W50-220, W50-225, W50-250, W50-275, W50-300, W50-330, W50-360, W50-390, W50-420, W50-490. Program controller
SIEMENS programmable controller
SIEMENS program controller LOA24.171B27, SIEMENS program controller LOA44.252A27
SIEMENS program controller LMO44.255C2, SIEMENS program controller LAL1.25
SIEMENS program controller LAL2.25, LAL1.25BT, LAL2.25BT, LAL1.25EM, LAL2.25EM, LAL1.25RL, LAL2.25RL), SIEMENS program controller LFL1.322, SIEMENS program controller LFL1.335, SIEMENS program controller LFL1.333, SIEMENS program controller LFL1.635, LFL1.322BT, LFL1.335BT, LFL1.333BT, LFL1.635BT,
LFL1.322RL、LFL1.335RL、LFL1.333RL、LFL1.635RL,LFL1.322EM、LFL1.335EM、LFL1.333EM、LFL1.635EM
SIEMENS combustion program controller
LFL combustion process controller LFL1.333, LFL1.322, LFL1.335, LFL1.635, LFL1.622
LAL fuel combustion controller LAL1.25, LAL2.25, LAL3.25, LAL2.14, LFL1.333BC
LGK dual-purpose combustion controller LGK16.333A27, LGK16.322A27, LGK16.335A27, LGK16.622A27, LGK16.635A27
LOK16 fuel combustion controller LOK16.250A27,
LMV5 series air-fuel ratio combustion management system LMV51.100C2, LMV52.200B2,
LEC1 large combustion controller LEC1/8892, LEC1/8851, LEC1/8853, LFE1/8851,
LFE1 intermittent operation gas combustion controller with any capacity LFE1/8851, LFE1/8853
LGB2 mechanical combustion controller LGB21.330A27, LGB22.330A27, LMG22.330B27
Siemens LDU11 gas leak detector LDU11.523A27, LDU11.323A27,
LMV27 electronic air-fuel ratio controller LMV27.100A2
LME7 integrated function controller LME71.0000A2, LME73.0000A2
AZL display operation unit AZL21.00A9, AZL23.00A9, AZL52.00B1, AZL52.401
Siemens proportional regulator RWF50.20A9, RWF50.30A9, RWF55.50A9
Siemens power adapter AGG5.220, AGG3.131,
Siemens speed sensor AGG5.315
Siemens analog input module AGG56.41A27, AGG56.91A27
KF8804 Siemens LFL1 test unit, PLL52.110A200 flue gas oxygen measurement module
AGO20.002A flue gas collector, auxiliary components of AG flame detector,
Combustion controller • Medium and large capacity burners for forced ventilation of fuel oil, gas or dual fuel • Intermittent operation burners for multi-section or continuous proportion • With damper detection • Flame monitoring – UV flame detector QRA... – The ion probe LFL1... series controller is particularly suitable for OEMs integrating combustion control into their products Purpose - monitor the forced draft burner with expansion flame or pilot fire (ignition) interruptible structure - medium to large capacity - intermittent operation (at least one controlled shutdown every 24 hours) - multi-section or continuous proportional burner - dual fuel burner - fixed air preheater 01 and 02 series. For pilot fire (ignition) burner with pilot fire gas valve, the main reason is the length of safety time. LFL1.638 is suitable for large-capacity atmospheric burner
Payment Terms: | wire transfer |
| |