Winner 2309 wet laser particle size analyzer

Model:Winner 2309 A/B
Brand:Winner
Origin:Made In China
Category:Industrial Supplies / Industrial Supplies Stocks
Label:wet and dry
Price: US $33598 / pc
Min. Order:1 pc
Inquire Now

Member Information

Detail

Product Description

 

Product Description

Winner2309 is intelligent full automatic laser particle size analyzer,adopt MIE scattering principle, which is integrated model of wet and dry dispersion system. It’s the prior choice for industrial production quality control departments and research institutions which have more types of particles and wide particle size distribution.

 

Main Features

(1)Wet and dry, seperated dispersion unit
This instrument integrated wet and dry dispersion test in one, successfully resolved the problem of dry and wet technology integration, realize one key to switch.

(2) Intelligent full automatic operation system and manual operation, freely choose.
Choose automatic mode, very easy and simple to learn,support one key operation.

(3)Optical Path System patented technology
Converging light Fourier transform path system, enables scattering light be not restricted to the lens aperture limit, and the dual laser orthogonal light use auxiliary semiconductor laser to expand the measurement range by enlarge scattering angle from 45 degrees to 135 degrees.

(4) Automatic Optical path alignment System,
which is composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level,make optimum optical paths to ensure accurate and stable test.

(5) Full built-in Sample dispersion system.
set mechanical stirring, ultrasonic dispersion, and circulation path in one, It ensures particles uniform dispersion and distribution,avoids many bad phenomenon, such as uneven distribution of particles, large particles deposit because of the long outer dispersing system tube, And it guarantees the representativeness of test result.

(6)Instrument Software
Original Unconstrained free fitting technology collect scattering data during the measurement process, make particle analysis not be restricted by any functions, truly reflect particles distribution.

Specification

Model Name

Winner2309A|Winner2309B

Standard

ISO13320-1:2009,GB/T19007-2016,Q/0100JWN001-2013
Compliance with 21 CFR Part 11

Principle

Laser diffraction principle

Analysis

Mie and Fraunhofer scattering

Detector Arrangement

Log-spaced array, test angle from 0.015 degree to 145 degree

Measuring Range

Wet:0.01μm-2000 μm Dry: 0.1μm-2000μm |Wet:0.01μm-1200 μm Dry: 0.1μm-1200μm

Silicon Photodetectors

Wet:127 pcs Dry:100 pcs

Accuracy error

Wet≤0.5% Dry≤1% (CRM D50)

Repeatability error

Wet≤0.5% Dry≤1% (CRM D50)

Light source

High performance semiconductor red laser (λ=639nm )
P>3.0MW
Auxiliary green solid semiconductor laser (λ= 405 nm)
P>2.0MW (available)

Optical path

Converging light Fourier transform optical path

Effective focal length

500mm

Laser Safety

Class 1

Wet dispersion

Ultrasonic

Frequency:40KHz Power:60W, Time: ≥1S

Stir

Revolutions Speed: 0-3000RPM (Adjustable)

Circulate

Rated Flow:30L/min Rated Power:70W

Water level sensor (UK

Prevent water overflow and effectively protect the instrument

Sample tank

Volume:1000mL

Micro-
Sample cuvette

Volume: 10mL ( Available)

Dry dispersion

Dry-turbulence dispersion patent technology, normal shock wave shear technique

Feeding Speed

Adjustable (Variable speed knob)

Operation Mode

Full automatic / manual control, freely choose

Dispersion medium

Compressed Air, pressure: 0 to 6 bar

Optical bench alignment system

Full automatic, precision is up to 0.2um

Full Test Speed per time

Wet: <2 Min Dry : <1min
Inverval time per test result :500ms

Outer dimension

Host machine: L120cm×W37cm×H56cm 

wet distribution box: L44.2cm×W28cm×H34.2cm

Net Weight

62Kg+15Kg

 

Principle

Test Operation Interface:

Quality Assurance

1. Strictly conforming to ISO9001-2000 quality management system.2. Strict control from purchasing materials, process inspection to final particle size distribution test.

3. QC department to execute quality control regulations.
4.Only qualified components will be assembled and total laser particle size analyzer must be inspected completely before sale.
5.Laser particle size analyzer will be processed preventing -shake test before delivery.

After Sale Service

1.Operation demo video CD will be offered.

2. Offer free-training service.

3. The quality assurance date is 1 year since finishing payment, Technology support will be provided for life. And after that, we will collect the cost if provide repair accessories.

4. Maintenance for equipment failure caused by improper handling (appropriate cost will be collected).

5. We offer the components with favorable price and perdurable maintenance.

 

Packing List

NO.

Items

Quantity

Unit

1

Winner2309 laser particle size analyzer

1

Set

2

Software

1

Set

3

Software key

1

PCS

4

Standard sample

1

Bottle

5

Power cable

1

PCS

6

Communication cable

1

PCS

7

Sample cuvette

1

PCS

8

Screwdriver

2

PCS

9

Wrench

3

PCS

10

Draining water pipeline

1

PCS

11

Standard sample pipeline

1

Set

12

Clean mirror paper

3

PCS

13

Clean mirror card

1

PCS

14

Sample cuvette brush

2

PCS

15

Spoon

2

PCS

16

2A fuse

5

PCS

17

Quality certificate

1

PCS

18

Warranty Card

1

PCS

19

Manual

1

PCS


Product Image

Winner 2309 wet laser particle size analyzer  1
Img 1
Winner 2309 wet laser particle size analyzer  2
Img 2
Winner 2309 wet laser particle size analyzer  3
Img 3
Winner 2309 wet laser particle size analyzer  4
Img 4

Send Inquiry to this Member

Jinan Winner Particle Instrument Stock Co., Ltd.

Unit 2, East, Building F, North District, University Science and Technology Park, No. 750 Shunhua Road, Lixia District

Phone:
+86-0531-88876213
Fax:
Contact:
Ella Ren (Foreign trade operat)
Mobile:
17362290807

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Industrial Supplies Stocks Made In China Products

,  

Industrial Supplies Stocks China Suppliers and China Manufacturers