Product Description
Winner2309 is intelligent full automatic laser particle size analyzer,adopt MIE scattering principle, which is integrated model of wet and dry dispersion system. It’s the prior choice for industrial production quality control departments and research institutions which have more types of particles and wide particle size distribution.
Main Features
(1)Wet and dry, seperated dispersion unit
This instrument integrated wet and dry dispersion test in one, successfully resolved the problem of dry and wet technology integration, realize one key to switch.
(2) Intelligent full automatic operation system and manual operation, freely choose.
Choose automatic mode, very easy and simple to learn,support one key operation.
(3)Optical Path System patented technology
Converging light Fourier transform path system, enables scattering light be not restricted to the lens aperture limit, and the dual laser orthogonal light use auxiliary semiconductor laser to expand the measurement range by enlarge scattering angle from 45 degrees to 135 degrees.
(4) Automatic Optical path alignment System,
which is composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level,make optimum optical paths to ensure accurate and stable test.
(5) Full built-in Sample dispersion system.
set mechanical stirring, ultrasonic dispersion, and circulation path in one, It ensures particles uniform dispersion and distribution,avoids many bad phenomenon, such as uneven distribution of particles, large particles deposit because of the long outer dispersing system tube, And it guarantees the representativeness of test result.
(6)Instrument Software
Original Unconstrained free fitting technology collect scattering data during the measurement process, make particle analysis not be restricted by any functions, truly reflect particles distribution.
Specification
Model Name |
Winner2309A|Winner2309B |
|
Standard |
ISO13320-1:2009,GB/T19007-2016,Q/0100JWN001-2013
|
|
Principle |
Laser diffraction principle |
|
Analysis |
Mie and Fraunhofer scattering |
|
Detector Arrangement |
Log-spaced array, test angle from 0.015 degree to 145 degree |
|
Measuring Range |
Wet:0.01μm-2000 μm Dry: 0.1μm-2000μm |Wet:0.01μm-1200 μm Dry: 0.1μm-1200μm |
|
Silicon Photodetectors |
Wet:127 pcs Dry:100 pcs |
|
Accuracy error |
Wet≤0.5% Dry≤1% (CRM D50) |
|
Repeatability error |
Wet≤0.5% Dry≤1% (CRM D50) |
|
Light source |
High performance semiconductor red laser (λ=639nm )
|
|
Optical path |
Converging light Fourier transform optical path |
|
Effective focal length |
500mm |
|
Laser Safety |
Class 1 |
|
Wet dispersion |
Ultrasonic |
Frequency:40KHz Power:60W, Time: ≥1S |
Stir |
Revolutions Speed: 0-3000RPM (Adjustable) |
|
Circulate |
Rated Flow:30L/min Rated Power:70W |
|
Water level sensor (UK |
Prevent water overflow and effectively protect the instrument |
|
Sample tank |
Volume:1000mL |
|
Micro-
|
Volume: 10mL ( Available) |
|
Dry dispersion |
Dry-turbulence dispersion patent technology, normal shock wave shear technique |
|
Feeding Speed |
Adjustable (Variable speed knob) |
|
Operation Mode |
Full automatic / manual control, freely choose |
|
Dispersion medium |
Compressed Air, pressure: 0 to 6 bar |
|
Optical bench alignment system |
Full automatic, precision is up to 0.2um |
|
Full Test Speed per time |
Wet: <2 Min Dry : <1min
|
|
Outer dimension |
Host machine: L120cm×W37cm×H56cm
wet distribution box: L44.2cm×W28cm×H34.2cm |
|
Net Weight |
62Kg+15Kg |
Principle
Test Operation Interface:
Quality Assurance
1. Strictly conforming to ISO9001-2000 quality management system.2. Strict control from purchasing materials, process inspection to final particle size distribution test.
3. QC department to execute quality control regulations.
4.Only qualified components will be assembled and total laser particle size analyzer must be inspected completely before sale.
5.Laser particle size analyzer will be processed preventing -shake test before delivery.
After Sale Service
1.Operation demo video CD will be offered.
2. Offer free-training service.
3. The quality assurance date is 1 year since finishing payment, Technology support will be provided for life. And after that, we will collect the cost if provide repair accessories.
4. Maintenance for equipment failure caused by improper handling (appropriate cost will be collected).
5. We offer the components with favorable price and perdurable maintenance.
Packing List
NO. |
Items |
Quantity |
Unit |
1 |
Winner2309 laser particle size analyzer |
1 |
Set |
2 |
Software |
1 |
Set |
3 |
Software key |
1 |
PCS |
4 |
Standard sample |
1 |
Bottle |
5 |
Power cable |
1 |
PCS |
6 |
Communication cable |
1 |
PCS |
7 |
Sample cuvette |
1 |
PCS |
8 |
Screwdriver |
2 |
PCS |
9 |
Wrench |
3 |
PCS |
10 |
Draining water pipeline |
1 |
PCS |
11 |
Standard sample pipeline |
1 |
Set |
12 |
Clean mirror paper |
3 |
PCS |
13 |
Clean mirror card |
1 |
PCS |
14 |
Sample cuvette brush |
2 |
PCS |
15 |
Spoon |
2 |
PCS |
16 |
2A fuse |
5 |
PCS |
17 |
Quality certificate |
1 |
PCS |
18 |
Warranty Card |
1 |
PCS |
19 |
Manual |
1 |
PCS |