Home > Products > Electronics & Electricity > Electronic Instrument > Air & Gas Flowmeter

ABB  Electromagnetic flow meter FEP311/FEP315/FEP321/FEP325/FET321/FET325 1
  • ABB  Electromagnetic flow meter FEP311/FEP315/FEP321/FEP325/FET321/FET325 1

ABB Electromagnetic flow meter FEP311/FEP315/FEP321/FEP325/FET321/FET325

Model:FEP300 series
Brand:ABB
Origin:-
Category:Electronics & Electricity / Electronic Instrument / Air & Gas Flowmeter
Label:FEP311/FEP315 , FEP321/FET321 , FEP325/FET325
Price: -
Min. Order:5 pc
Inquire Now

Member Information

Detail

TEK ELECTRONICS (HONGKONG) CO.,LTD

Biz MemberGuang Dong - China
Last Online:27 Jun, 2024

Product Description

ProcessMaster Electromagnetic flowmeter

                 FEP311.                                                FEP315                              FEP315
(without explosion protection)                         (Zone 2 / Division 2)          (Zone 1 / Division 1)

Measured error Default: 0.4 % of measured value, 0.2 % of measured value
Nominal diameter range DN 3 ... 2000 (1/10 “ ... 80 ")
Process connection6) Flange in accordance with DIN 2501 / EN 1092-1, ASME B16.5 / B16.47, JIS, AS2129
Nominal pressure PN 10 … 100, ASME CL 150, 300, 600, 900, 1500, 2500
Liner Hard rubber (DN 15 ... 2000), soft rubber (DN 50 ... 2000), PTFE (DN 10 ... 600),
PFA (DN 3 ... 200), ETFE (DN 25 ... 600), Linatex (DN 50 ... 600)
Conductivity > 5 μS/cm (20 μS/cm for demineralized water)
Electrodes Stainless steel, Hastelloy B, Hastelloy C, platinum-iridium, tantalum, titanium, tungsten carbide
Process connection material Steel, stainless steel
IP rating IP 65, IP 67
Measuring medium temperature -25 ... 180 °C (-13 ... 356 °F)
Power supply 100 ... 230 V AC (-15 / +10%), 24 V AC (-30 / +10%), 24 V DC (-30 / +30%)
current output 4 ... 20 mA, active or passive
Pulse output Can be configured locally as active or passive using software
Switch output / switch input Optoelectronic coupler, programmable function
Display Graphical display, configurable
Housing Integral mount design: choice of single-compartment housing or dual-compartment housing.
Communication HART protocol (standard), PROFIBUS PA, FOUNDATION Fieldbus (option)
Explosion protection approvals • ATEX / IECEx zone 1, 2, 21, 22
• FM / cFM Cl 1 Div 1 (≤ DN 300), Cl 1 Div 2
• NEPSI zone 1, 2
• GOST zone 1, 2
Pressure Equipment Directive 97/23/EC Conformity assessment in accordance with category III, fluid group 1
CRN (Canadian Reg.Number) On request

1) Single-compartment housing.
2) Dual-compartment housing.
3) Design level "B" sensor.
4) Design level "B" sensor, all versions made from stainless steel.
5) Design level "C" sensor, DN 25 … 600.

Sensors

FEP321.                                                             FEP325.                                   FEP325

(without explosion protection)                 (Zone 2 / Division 2)                   (Zone 1 / Division 1)

Transmitters:

FET321.                                                             FET325.                                   FET325

(without explosion protection)                 (Zone 2 / Division 2)                   (Zone 1 / Division 1)

Sensor
Measured error Default: 0.4 % of measured value, 0.2 % of measured value
Nominal diameter range DN 3 ... 2000 (1/10 “ ... 80 “)
Process connection5) Flange in accordance with DIN 2501 / EN 1092-1, ASME B16.5 / B16.47, JIS 10K
Nominal pressure PN 10 … 100, ASME CL 150, 300, 600, 900, 1500, 2500
Liner Hard rubber (DN 15 ... 2000), soft rubber (DN 50 ... 2000), PTFE (DN 10 ... 600),
PFA (DN 3 ... 200), ETFE (DN 25 ... 600), Linatex (DN 50 ... 600)
Conductivity > 5 μS/cm (20 μS/cm for demineralized water)
Electrodes Stainless steel, Hastelloy B, Hastelloy C, platinum-iridium, tantalum, titanium, tungsten
carbide
Process connection material Steel, stainless steel
IP rating IP 65, IP 67, IP 68, (NEMA 4X)
Fluid temperature -25 ... 180 °C (-13 ... 356 °F)
Transmitters
Power supply 100 ... 230 V AC (-15 / +10 %), 24 V AC (-30 / +10 %), 24 V DC (-30 / +30 %)
current output 4 ... 20 mA, active or passive
Pulse output Can be configured locally as active or passive using software
Switch output / switch input Optoelectronic coupler, programmable function
Display Graphical display, configurable
Housing Field mount housing: choice of single-compartment housing or dual-compartment housing
Communication HART protocol (standard), PROFIBUS PA, FOUNDATION Fieldbus (option)
Approvals
Explosion protection approvals • ATEX / IECEx zone 1, 2, 21, 22
• FM / cFM Cl 1 Div 1 (≤ DN 300), Cl 1 Div 2
• NEPSI zone 1, 2
• GOST zone 1, 2
Pressure Equipment Directive 97/23/EC Conformity assessment in accordance with category III, fluid group 1
CRN (Canadian Reg.Number) On request
1) Design level "B" sensor.
2) Design level "C" sensor, DN 25 … 600.
3) Single-compartment housing.
4) Dual-compartment housing


Payment Terms:T/T

Product Image

ABB  Electromagnetic flow meter FEP311/FEP315/FEP321/FEP325/FET321/FET325 1
Img 1

Send Inquiry to this Member

TEK ELECTRONICS (HONGKONG) CO.,LTD

ROOM 509,5/F, International Commercial building Bao An Bei Road,LuoHu District ShenZhen CIty,GuangDong Province

Phone:
00-852-557-452-62
Fax:
86
Contact:
Tony (MD)
Mobile:
136-0304-2874
This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Air & Gas Flowmeter Made In China Products

,  

Air & Gas Flowmeter China Suppliers and China Manufacturers