Model: | 3C10KS/ 3C15KS |
---|---|
Brand: | SANTAKUPS |
Origin: | Made In China |
Category: | Electronics & Electricity / Power Supply & Distribution / UPS |
Label: | UPS , INVERTER , POWER SUPPLY |
Price: |
-
|
Min. Order: | 500 pc |
Last Online:08 Jun, 2007 |
Castle series UPS
Key Features
True online double conversion technology
Wide input voltage range
Zero transfer time
Protection against all types of power problems
No add-on CNTL unit required for parallel connection
Low initial investment and flexible for future expansion
Highest reliability and maximum performance for power sharing and redundancy
Equipped with Maintenance Bypass Switch
N+1 Parallel Redundancy:
Allows a 6 kva to grow upto 18kva or 12kva with 6 kva redundancy and a 20 kva to 60 kva or 40 kva with 20 Kva redundancy allowing user to add capacity as needed and lower investment.
Simplified board separation:
Dependent on the Units all operation are separated into 5 pcb boards allowing quick respond to damages and provides our valued dealers with simplified inventory and faster service to the end users.
Dynamic Bypass:
Automatic dynamic Bypass and manual Bypass provide a loop to repair UPS with out having to disconnect loads ideal for non stop computing for critical applications.
Sine-wave output:
True sine-wave output with a 3% THD on batteries. This feature provides dependable and compatible power for your most critical applications.
True double conversion technology with zero Transfer Time:
This advance design provides the closest you can get to Pure constant power in the industry
Applications: Server, Data-center, Critical network devices, Sensitive electronic equipment, Telecom…
Technical Specifications
Model | ||||||
Rated Power | VA/W | 10KVA/7KW | 15KVA/10.5KW | 20KVA/14KW | ||
Input | Nominal Voltage | 380VAC | ||||
304 ~ 478VAC | ||||||
Phase | 3 phase (4 wires plus ground) | |||||
46 ~ 54Hz | ||||||
Power Factor | 0.95 | |||||
Connection | Hardwired | |||||
Output | Voltage | 220VAC ±1%, Single phase | ||||
Frequency | 50Hz ±0.1% ( | |||||
Waveform | Sine Wave | |||||
Power factor | 0.7 | |||||
Voltage Distortion | £ 2% under linear load | |||||
Overload Capability | 105% ~ 130% for 10 min., ³130% for 1 min. | |||||
Current Crest Ratio | 3:1 max. | |||||
Type | Sealed, Maintenance free, Lead-Acid | |||||
Nominal DC Voltage | 240VDC | |||||
Back-up time (full load) | Depends on the capacity of the external battery capacity | |||||
Connection | External | Hardwired | ||||
Transfer time | 0 ms | |||||
Maintenance Bypass Switch | Yes | |||||
LED indicators | Status | Load level/Battery level, | ||||
Audible alarm | Bypass | Alarm beeps every two minutes | ||||
Alarm beeps every four seconds, every second if battery low | ||||||
Overload | Alarm beeps two for every second | |||||
Fault | Alarm beeps continuously | |||||
Acoustic noise | At 1 meter distance | £ 55 dBA | £ 60 dBA | |||
Communications | DB-9 Port | RS232 serial interface | ||||
Intelligent Slot | Options: WebPower, As400 or WinPower CMC | |||||
up to three units in parallel for power redundancy and load sharing | ||||||
Environmental | Operating temperature | 0 ~ |