Home > Products > Security & Protection > Surveillance Equipment

AV input MMS Alarm System  1AV input MMS Alarm System  2AV input MMS Alarm System  3
  • AV input MMS Alarm System  1
  • AV input MMS Alarm System  2
  • AV input MMS Alarm System  3

AV input MMS Alarm System

Model:DVR Alarm
Brand:SANGGANG
Origin:Made In China
Category:Security & Protection / Surveillance Equipment
Label:DVR alarm , AV alarm , MMS alarm
Inquire Now

Product Description

GSM-AV MMS Alarm System
 
Manual
 
 
 
 
 
 
 
 
GSM-AV MMS visual alarm system use to the villa, houses, shops, company, the factory workshop, school, hospital financial business place, etc .where important parts of the security alarm, monitoring photo taking, wireless transmission, MMS received.
1)      Basic function of base
1 Use CCD/CMOS analog camera with NTSC/ PAL formats on the market.
2, Two video input alarm and take pictures.
3, Video input motion detect.
4, Video output to TV screen, change screen automatically when alarm.
5, Record photos in SD card.
6, Wireless control to control base.
7, Support all kinds of wireless detector, infrared fences, smoke, gas, etc.
8, Two line input, convenient connection line alarm equipment.
9, Sixteen wireless zones with 16 messages to show alarm places.
10, Each camera can fit any wire or wireless zones detectors.
11, A relay output, convenient to control power on or off.
12, A external speaker interface, can alarm mute/ siren.
13,Five groups of different alarm phone and room information.
14, One center alarm phone.
15, Two E-mail box.
16, IP network if needs.
17,Call in to controller the base alarm or disarm, monitor and taking pictures. etc.
18, Password to ensure system security.
19, With GSM 850/900 /1800 /1900MHz.
20, Built-in lithium battery and automatic charger.
 
2) The pin behind base
1 , RESET button, hold down RESET button and then power on, 3 seconds after hearing a loud ( or orange lamp change to red light, again, change to orange light), the base recovery to the initial state, the password is 123456, the base of all the detector memory is empty.
2, SIM card, with a pen pressure the edge of the yellow spot, you can take out the GSM card.
3, MIC, a hole for monitor.
4, 8 core connection: L1; L2; RELAY1; RELAY2; SIREN; GND; VDD; ANT;
L1and L2 are cable inputs, each port short or open to triggered alarm. RELAY1; RELAY2; this two port usually disconnect, it close 3 minutes when alarm, it can connect with power supply to the lights and work; you can control it on or off also. SIREN is the external alarm the port, direct connection active siren, the other end of the siren connect with GND. GND. VDD (+ 12 V) output, which can be used for a camera or cable detector power supply. ANTENNAis for the remote control.
 
5, Power on/ off, turn right to power on.
6, power supply12V/1.5A DC, which core is positive and shell is negative.
7, Analog camera 1 put Vin1, analog camera 2 put Vin2, VOUT to TV screen.
7, SD card socket, can insert 2G or more memory card.
8, LED indicator light, a green light, base show removal state. a green slow flash, base show protection status. Red lights flashing, the host in a state of alarm.
Note: antenna is a ANT.
 
3Power on base
1, buy a new SIM card, put it into the back of the base, connect with GSM antenna.
2, cameras connect to Vin1 and Vin2. TV connected to the Vout
3, SD card in the base if you have.
4, Put the DC power supply (12 V / 1.5A) into the base, turn on the switch, the base orange lamp slow flash show checking the GSM network and testing the SIM card. The base orange lights flash to detect a camera. After 20 second, green light show base self-check success, the base inter into disarm state. If the green slow flash, it show in protection state. If the red slow flash, it sent SMS; if the red fast flash, it send MMS.
 
4Set5 groups of phone in base
User can send SMS to base with the SIM card to setting, format as follows:
Serial number # telephone number # message switch # MMS switch # phone switch #; (0-shut, and 1-open), as:
123456#31#13905950001#1#1#1#, it can send SMS, MMS, and call out 13905950001 when alarm.
123456#32#13905950002#1#1#0#, it can send SMS, MMS to 13905950002 when alarm.
123456#33#13905950003#1#0#1#, it can send SMS, and call out 13905950003 when alarm.
123456#34#13905950004#0#1#1#, it can send MMS, and call out 13905950004 when alarm.
123456#35#13905950005#0#0#1#, it can call out 13905950005 when alarm.
 
5)  Test base alarm function
When base is in removal state with green light on, you can use the remote control or send SMS (123456 # 11 # 1 #) to base to make in protection state. When base is in protection state with green light slow flash, line detector and wireless detector trigger alarm (wireless infrared, wireless door magnetic ,emergency button ), all can make alarm, and sent out the alarm information.
1, base open SMS/MMS alarm function, it can send SMS/MMS and dial out. If base closed SMS/MMS alarm functions, is directly dial out. In the alerting, you can use the remote control to end it.
2, In the alerting, you answer the phone, you can monitoring it and use the keyboard to controller base.
3, In the alerting, base can take pictures save in SD card if you set.
4, Normal, you can send SMS to controller the base.
 
6Set base by SMS
Send SMS to base, message formats such as: password # operation codes #.
123456#11#1#, set base in protection state with green light slow flash.
123456#16#1#, set the current monitor camera for Vin 1(Image motion detection), and it connect to Vout
123456#1#1#5#, set Vin1 camera to take pictures immediately and sent out 5 pcs to the phone.
123456#18#888000#, change the password to 888000
123456#41#269999 @163.com#, set the first email address.
If you need to install alarm center phone without CID, you can send SMS as 123456#51# 88886666#0001#0#, show alarm center phone is 88886666 (0-15 bit), the user base ID is 0001(4 bit), the user base will dial 88886666 and send 0001(DTMF signal) to the center phone when alarm . The last 0#,means it can not dial out when the base is protection or removal. The last 1#,means it can dial out when the base is protection or removal.
123456#52#88883333#88884444#, set protection center phone is 88883333, removal center phone is 88884444, the user makes alarm, base will dial 88883333,The user makes disarm, base will dial 88884444, center phone don't answer, it can know that users is protection or removal according to CID.
123456#53#125.077.224.103# 0900#0001#,          set IP alarm center, IP address is 125.077.224.103, port : 0900, the user ID: 0001, according to the local fixed IP address and port number.
123456#54#13900000000#, Set alarm SMS center number is 13900000000.
When you send SMS to the base, the base will return a message after setting, the format (according to different Settings):
disarm; Siren on; MMS picture 1; Image serial number 1: image detect open; Password 123456; Version: Chinese
 
 
operation
Function description
Ask picture:            1# (camera serial number 1-2 ) # (picture number 1-20) #
2#-#
3#-#
5#-#
Control relay: 5#1#; relay close,  #5#0#; relay open, (normally, relay will close 3 Min when alarm)
11#-#
Set base arm or disarm:        11 # 1 # ;protection,    11 # 0 #; removal
13#-#
Set siren on/off when alarm      13#1#; siren on,    13#0#; siren off
14#-#
Set send MMS number of sheets when alarm: 14 # (MMS number 1-20) #
16#-#
Set the current monitor camera: 16# (camera serial number 1-2) #
17#-#
Set image detect switch: 17#1# :on, 17#0#: off
18#-#
change the password:         18#(new code 1-6bit)#
19#-#
Set Version:         19#1#, Chinese19#0#, English
20##
Check the MMS configuration:       20##
Set MMS configuration:   21# APN# USER# PASS# IP# PORT# MMS Home#
30##
Checkphones:   30##
31#-35#
phone:     (31-35)#phone(1-5)# SMS(1,0)# MMS(1,0)#dial(1,0)#
Checkmailbox:  40##
41#-#
42#-#
Set Email 2:     41# ( Email Address 2)#
50##
Check center number configuration:   50#(1-5)#
51#-#-#
Set center phone 51# (center phone) # ID (4 bit) # arm or disarm report(1,0)#
52#-#-#
Set protection or removal center phone 52# protection phone # removal phone #
53#-#-#
Set IP center :       53#IP#PORT#user ID#
54#-#
Set SMS center :       54# SMSphone #
55#-#-#-#
Inspection time:(1-99 )hourtype0 =(SMS)1 =(MMS)2 =(SMS+MMS)
60#-#
Check line portstatus:    60#1# or 60#2#
61#-62#
(61-62)# arm status(0-2) # Triggering mode(0-1) # camera Number(1-2) # message(1-24bit)#
Arm status (0—disarm,1--arm,2--24hours arm), Triggering mode(0—input close,1-- input open), Camera Number(1-2,which camera will take picture when input trigger).
70##
Check wireless detectors status:   70# (1-16)#
71#-86#
(71-86)# arm status(0-2) # camera Number(1-2) # message(1-24bit)#
Arm status(0--disarm,1--arm,2--24hours arm), Camera Number(1-2,which camera will take picture when input trigger).
 
Note: If not used in CHINA, the base will reset MMS configuration according to different countries.
The host has fix 16 messages, corresponding 16 wireless zones: "wireless alarm (zone 1-16)"
Line trigger alarm: "line alarm"
Wireless detector trigger alarm: "wireless alarm"
Emergency alarm: "emergency"
When the host is reset, wireless detector in empty in the base, the first wireless detector study in the host is the wireless alarm zone 1, in turns, users can distinguish it.
The user can send text messages to a wire or wireless zone for arm or disarm and change the message display:
123456#61#2#1#1# the window was opened #, instead of " line alarm (zone 1) ", and began to 24 hour protection and take picture camera 1 when line 1 break(open) make alarm.
123456#71#1#1# the front door open #, instead of "wireless alarm (zone 1), and began to protection and take picture camera 1 when alarm"
Note: the user set text message content is not more than 12 Chinese or 24 English letters. If the host reset, text messages will recover to fix 16 messages.
 
7) Dial in to monitor the spot
Users call the base, can hear a “ bi ”,then monitor spot voice.
 Note: base will not response you if your phone number is not save in the base.
 
8) Add new detector to base
when the base in normally (green bright or flashing), You can push on RESET button on the back of the base for a while, the base turned bright red lights, then set the detector emit, the LED flash or external siren“ bi ”a sound, show the base has confirmed the detector. If we hold down the RESET button a second or after 20 seconds later, the base turn back to be normal.
 
9) Cancel the lost detector saved in base
When the wireless detector (such as remote control) is lost, you need to be removed from the base. The method is: hold down the RESET button and open power supply, 3 seconds after hearing a loud or orange lamp change red light, again, a red light to orange light, the system restore to the initial state, the password for 123456, the base clear all the detectors. Message content for the recovery has fix 16 text message. you mush reprogram wireless detector again.
 
10) Use controller to remote base
Wireless remote control has four key: alarm keys, disarm key, emergency key, function keys.
When you click the alarm keys, the base panel LED lights flashing green, when detector trigger, base will delay ten seconds and make alarm, dial out and send SMS/MMS, this time the host panel lights flashing LED into the red. When you click the disarm key, the host panel LED light green, then detectors trigger will not make alarm.
When you press the emergency button, base can make alarm, no matter base is in alarm or disarm status.
 

Emergency

 
Function
Alarm
Disarm

 

 11) LED light on base panel
when the base power on, LED is orange, when the base check the GSM network and test the SIM card, LED is orange slow flash. When the base check camera, LED is orange flash. After 20 seconds, LED is green light, show the base self-check success. The base to be automatic into disarm state. The base is in alarm state with green slow flash. The base is in alarming state with red slow flash. The slow flash shows to send SMS; The red light flash shows to send MMS.
 
12) Main technical parameters
1, state current: 40mA
2, power supply: 12 V / 2A
3, work temperature:-40℃-- 85℃
4, support GSM850/900/1800/1900 MHz
5, receive code: ASK
6, receive frequency: 315/433 MHz
7, remote distance: 100 m (open)
8, detector number: 16
Note: 0: pin connect low level; 1: pin connect high level; ∞: pin not connect.
 
type
2262 IC (pin)
10
11 
12 
13 
Outdoor alarm
1
0
0
0
Indoor alarm
0
0
0
1
Disarm
0
0
1
0
Emergency
0
1
0
0
Door detect
0
0
IR- detect
1
0
1
0
Smoke detect
1
1
1
0
Help
0
1
0

Product Image

AV input MMS Alarm System  1
Img 1
AV input MMS Alarm System  2
Img 2
AV input MMS Alarm System  3
Img 3

Send Inquiry to this Member

Quanzhou Licheng Xingguang New Technology Development Co., Ltd.

Sanpinjie,2-59,Quanzhou ,Fujian,China

Phone:
86-595-22993198 22286818
Fax:
86-595-22280025
Contact:
zheng canmin (direct)
Mobile:
0595-22993198

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Surveillance Equipment Made In China Products

,  

Surveillance Equipment China Suppliers and China Manufacturers