Model: | MKV-710B |
---|---|
Brand: | KEM |
Origin: | Made In Japan |
Category: | Electronics & Electricity / Electronic Instrument / Analysis Instrument |
Label: | Compact , Volumetric , KF Titrator |
Price: |
-
|
Min. Order: | 1 pc |
Last Online:01 Jun, 2024 |
Karl Fischer Moisture Titrator (Volumetric titration) [MKV-710B]
A single burette is equipped as standard.
High-performance titrator at a lower price
Features
New burette unit
Measurement results are converted to PDF and can be stored in a USB flash drive
End point detection by compensating liquid resistance is adopted. (Japanese Patent No. 1896338)
Can resume titration automatically after interruption
By connecting an Android device , a titration curve can be displayed in real-time
Specifications
Type |
Karl Fischer Moisture Titrator |
||||||||||||||||||||
Model |
MKV-710B |
||||||||||||||||||||
Product configuration |
MKV-710+IDP-100+Automatic Solvent Change unit |
||||||||||||||||||||
Measuring method |
Karl Fischer Volumetric titration |
||||||||||||||||||||
Measuring range |
1) Water content : 0.1 to 500mgH2O (depends on KF reagent factor)
|
||||||||||||||||||||
Burette precision |
10mL burette +/- 0.015mL ; reproducibility +/- 0.005mL |
||||||||||||||||||||
Endpoint detection |
By polarized potential level detected with a twin platinum electrode |
||||||||||||||||||||
EP sense method |
Detection of potential level maintained during preset end time.
|
||||||||||||||||||||
Titration form |
Normal titration / Back titration (Option additional burette required) |
||||||||||||||||||||
Required solvent |
30 to100mL (in S-type titration vessel) |
||||||||||||||||||||
Method |
20 |
||||||||||||||||||||
Key operation |
Sheet key |
||||||||||||||||||||
Displays |
1) Black and white LED-backlit LCD
|
||||||||||||||||||||
Calculation |
Concentration of water content , statistics data processing (mean , SD and RSD) and automatic averaging of blank value and factor value |
||||||||||||||||||||
Data storage |
100 samples |
||||||||||||||||||||
GLP conformance |
Registration of operator /Record of check results / Record of factor measurement / Management of conduction time |
||||||||||||||||||||
External I/O |
RS-232C port x2 :
|
||||||||||||||||||||
Extensibility |
Automatic piston burette : Can control max 2 burette drives
|
||||||||||||||||||||
Ambient condition |
|
||||||||||||||||||||
Power source |
AC100 to 240V +/- 10% 50/60 Hz |
||||||||||||||||||||
Power consumption |
|
||||||||||||||||||||
Dimensions |
|
||||||||||||||||||||
Weight |
|
||||||||||||||||||||
Conformity standard |
CE marking EMC : EN61326-1 LVD : EN61010-1 RE Directive
|