Home > Products > Services > Therapies

( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 1( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 2( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 3( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 4( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 5( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 6( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 7( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 8
  • ( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 1
  • ( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 2
  • ( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 3
  • ( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 4
  • ( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 5
  • ( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 6
  • ( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 7
  • ( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 8

( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma

Model:-
Brand:WASTON
Origin:Made In China
Category:Services / Therapies
Label:polyaxial screw , low-profile , spinal fracture
Price: -
Min. Order:-
Inquire Now

Member Information

Detail

Product Description


Product Name

M9 Spinal System

Consist

M9 U-screw+Fixed rod II+ Crosslinks

Indication

Used for dislocation,correction and fracture of spines

Product Name

Product No.

Dia

(mm)

Lengthmm)

Fixed rod II(Ø5.5)

10114-(060-200)

5.5 

60~200(in 10mm increments)

10114-(220-240)

5.5

220/240

10114(300-500)

5.5

300/400/500

Dynamic rod II

10119-(040/050/060)

5.5 

40/50/60

Application:L4-L5

10119-(140/150)

5.5

40/50

Application:L5-S1

10119-(280/290/210)

5.5

80/90/100

Application:L4-S1

10119-(390/310/311)

5.5

90/100/110

Application:L3-L5

10119-(413/414/415)

5.5

130/140/150

Application:L3-S1

Crosslinks III (Ø5.5)

10133-(160-175)

5.5 

60/65/70/75

Crosslinks IV (Ø5.5)

10134-(260-270)

5.5

60/65/70

U-screw VII(mono-axial)

10157-(130-140)

4.5 

30/35/40

10157-(235-240)

5.0 

35/40/45

10157-(335-350)

5.5 

35/40/45/50

10157-(435-455)

6.0 

35/40/45/50/55

10157-(535-555)

6.5 

35/40/45/50/55

10157-(635-650)

7.0 

35/40/45/50

U-screw VIII(poly-axial)

10158-(130-140)

4.5 

30/35/40

10158-(235-240)

5.0 

35/40/45

10158-(335-350)

5.5 

35/40/45/50

10158-(435-455)

6.0 

35/40/45/50/55

10158-(535-555)

6.5 

35/40/45/50/55

10158-(635-650)

7.0 

35/40/45/50

U-screw IX(long mono-axial)

10159-(235-245)

5.0

35/40/45

10159-(335-350)

5.5

35/40/45/50

10159-(440-455)

6.0 

40/45/50/55


Product Image

( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 1
Img 1
( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 2
Img 2
( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 3
Img 3
( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 4
Img 4
( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 5
Img 5
( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 6
Img 6
( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 7
Img 7
( Master 9 ) Spinal System--Titanium Alloy, Minimally invasive, Spinal, Trauma 8
Img 8

Send Inquiry to this Member

Changzhou Waston Medical Appliance Co., Ltd.

9 Xihu Road, Wujin Hi-Tech Industry Zone, Jiangsu Province, China 5 Longxiang Road, Nanxiashu Street, Wujin Hi-Tech Industry Zone, Jiangsu Province, China

Phone:
86-519-86522226
Fax:
86-519-86522226
Contact:
Marketing department (Director)
Mobile:
86522226
This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.