Micro differential pressure transmitter
Product Description
Product Description: Use the object of liquid, gas, or steam.The measurement range is 0-0.125 to 1.5 kPa (0-12.5 to 152 m m H 2 O) with an output signal of 4 to 20 mA dC power supply of 24V dC, and the transmitter works at 12VdC, up to 45V dC.Load characteristics: working principle: Product characteristics: structural parameters: the table scale is 45mm long; the accuracy level 2.5.ds RⅡ BT5 is installed in dangerous places with level 0.5 digital indicator accuracy; this safety type laⅡ CT5; (see explosion-proof type 1151 transmitter manual for details) measuring range and zero point external continuously adjustable; positive and negative migration shall not exceed the measuring limit after positive and negative migration.Maximum positive migration to minimum adjustment range of 500% maximum negative migration to minimum adjustment range of 600% temperature range amplifier working at-29~93℃ sensitive element working at-40 to 104℃ storage temperature-50 to 120℃ static and overpressure cutoffs on either side or side of the transmitter plus 0 (absolute pressure) -6.89MPa transmitter is not damaged.The transmitter can operate between a static pressure of 3.5kPa (absolute pressure) and 6.89MPa; the relative humidity of 0-100% volume variation of less than 0.16cm3 damping time constant is continuously adjustable between 0.4-4.0S.Start time 2S, no preheating.Technical indicators (vertical installation, range 0-0.25~1.5.kPa, no migration, under standard conditions).0.5% of soil with precision calibration range. Integrated errors including linear, variation and reproducibility.The insensitive zone instability does not exceed 0.5% of the maximum range of the ± within six months.Temperature impact maximum range 0-1.5 kPa zero point error: ± l% / 28℃ of the range.Total error: ± 1.5%mp ℃ of the range.static pressure affects zero error: 6.89MPa static pressure. Error is ± 1.0% range error: error is-1.75±0.75/%6.89Mpa Scale error is a systematic error that can be corrected in advance before installation.Vibration affects on an arbitrary axis with a frequency of 200Hz, resulting in an error of ± 0.05% / g of the maximum range.Power supply impact output changes are less than 0.005% / V.The load has no load impact on power supply stability.Installation location impact. When the measurement diaphragm is not vertically installed vertically, a zero error is less than 0.25kPa, but has no effect on the range, which can be corrected and eliminated.Structural index structural material isolation diaphragm and exhaust / exhaust valve: 316 stainless steel flange and joint: 316 stainless steel contact medium O type diagram: fluorinated rubber filling liquid: silicone oil bolt: carbon steel galvanized amplifier housing: low copper aluminum alloy coating: polyester epoxy resin.The two flanges are connected to 1 / 4-NPT, 54mm (218 "), 1 / 2-NPT, and 51,54,57mm (2", 218 ", 214").The l / 2-NPT thread end wire pipe and micro incense for electrical connection
Product Image
Send Inquiry to this Member
Related Products of this Company
This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please
click here.
China Suppliers Quick Searching:
,