Model: | E1000 |
---|---|
Brand: | SOTENG-CNC |
Origin: | Made In China |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | Variable inverter , AC inverter , VFD |
Price: |
-
|
Min. Order: | 1 pc |
Last Online:09 Aug, 2017 |
AC INVETER----E1000 Technical Specifications
|
Items
|
Contents
|
Input
|
Rated Voltage Range
|
3-phase 400V±15%; single-phase 230V±15%
|
Rated Frequency
|
50/60Hz
|
|
Output
|
Rated Voltage Range
|
3-phase 0~400V;3-phase 0~230V
|
Frequency Range
|
0.50~650.0Hz
|
|
Control
Mode
|
Carrier Frequency
|
2K~10KHz;
|
Input Frequency Resolution
|
Digital setting: 0.01Hz, analog setting: max frequency 0.1%
|
|
Control Mode
|
V/F control
|
|
Overload Capacity
|
150% rated current, 60 seconds.
|
|
Torque Elevating
|
Auto torque promotion, Manual Torque Promotion 0.1%~30.0%
|
|
V/F Curve
|
4 kinds of modes: beeline type, square type, under-defined V/F curve and auto torque compensation. .
|
|
DC Braking
|
DC braking frequency: 1.0~5.0 Hz, braking time: 0.0~10.0s
|
|
Jogging Control
|
Jogging frequency range: min frequency~ max frequency, jogging acceleration/deceleration time: 0.1~3000.0s
|
|
Auto Circulating Running and multi-stage speed running
|
Auto circulating running or terminals control can realize 15-stage speed running.
|
|
Built-in PID adjusting
|
Easy to realize a system for process closed-loop control
|
|
Operation Function
|
Frequency Setting
|
Potentiometer or external analog signal (0~5V, 0~10V, 0~20mA); keypad (terminal)▲/▼ keys, external control logic and automatic circulation setting.
|
Start/Stop Control
|
Terminal control, keypad control MODBUS control.
|
|
Running Command Channels
|
3 kinds of channels from keypad panel, control terminal and MODBUS.
|
|
Frequency Source
|
given digit, given analog voltage, given analog current, given pulse frequency, given MODBUS, PID adjusting and stage-speed control.
|
|
Accessorial frequency Source
|
given digit, given analog voltage, given analog current, PID adjusting and stage-speed control.
|
|
Optional
|
Built-in EMI filter, built-in braking unit, tele-control panel
|
|
Protection Function
|
Input out-phase, input under-voltage, DC over-voltage, over-current, over-load, current stall, over-heat, external disturbance
|
|
Display
|
LED nixie tube showing present output frequency, present rotate-speed (rpm), present output current, present output voltage, present linear-velocity, types of faults, and parameters for the system and operation; LED indicators showing the current working status of inverter.
|
|
Environment Conditions
|
Equipment Location
|
In an indoor location, Prevent exposure from direct sunlight, Free from dust, tangy caustic gases, flammable gases, steam or the salt-contented, etc.
|
Environment Temperature
|
-10℃~+50℃ |
|
Environment Humidity
|
Below 90% (no water-bead coagulation)
|
|
Vibration Strength
|
Below 0.5g (acceleration)
|
|
Height above sea level
|
1000m or below
|
|
Applicable Motor
|
0.2~500KW
|