Model: | - |
---|---|
Brand: | - |
Origin: | - |
Category: | Electronics & Electricity / Power Transmission Equipment & Transformer |
Label: | - |
Price: |
-
|
Min. Order: | - |
Last Online:10 Aug, 2011 |
Ø Power production and CO2 emission reduction calculation for 5
Ø Flexible output setup, suitable to various countries' local regulationSpecialized remote setting and detecting software, make the computer adjusting more intelligently
Ø Delicate machinery design and light component configuration
Ø Multi-protection design, make it more safe and reliable
Ø Electrophoresis painting and machinery design of high protection grade, suitable for install indoor and outdoor
Ø Wider range of operating temperature of -25~+50℃
Ø Plug-in connection for all DC and AC water proof connector and communication cable, easy to field wiring
Model |
SM3-3KTL |
SM3-5KTL |
SM3-7KTL |
SM3-10KTL |
|
INPUT(DC) |
(W)Recommended Input PV Power (W) |
3150 |
5250 |
7350 |
10500 |
(V)Max.PV Open Circuit Voltage |
270 |
270 |
315 |
270 |
|
(A)Max.PV Input DC Current |
18.53 |
30.9 |
43.2 |
61.76 |
|
(V)PV-voltage range, MPPT |
180~360 |
||||
Number of MPPT trackers/Max.number of strings (parallel) |
1/1 |
1/2 |
1/2 |
1/3 |
|
OUTPUT(AC) |
(W)Nom.AC Output Power |
3000 |
5000 |
7000 |
10000 |
(A)Max.AC Output Current |
5.45 |
9.09 |
12.72 |
18.18 |
|
(V±%)Nom.Grid Voltage/range |
380/380±20% of normal grid voltage by default, adjusted to local regulation |
||||
(Hz±%)Nom.AC Grid Frequency/Range |
50±0.5Hz of normal grid frequency by default, adjusted to local regulation |
||||
Factor |
≥0.99(Rated power) |
||||
Output Current THD(%) |
<5%(Rated power) |
||||
Max.Efficiency |
97.0% |
||||
Euro-Eta |
95.5% |
||||
Protection Devices |
Over/Under Voltage Protection |
● |
|||
Over/Under Frequency Protection |
● |
||||
Non-islanding |
● |
||||
Over Current Protection |
● |
||||
AC short-circuit protection |
● |
||||
Ground Fault Monitoring |
● |
||||
All-pole Sensitive Residual-current Monitoring Unit |
● |
||||
Reverse Polarity Protection |
● |
||||
Over Load Protection |
● |
||||
General Data |
Dimensions(H/W/D) |
510×315×183 |
605×550×205 |
695×648×232 |
|
Weight(kg) |
15 |
22 |
32 |
45 |
|
Operating temperature range |
-25~+50℃ |
||||
(W)Power consumption at night |
0.25W |
||||
Noise |
≤ 42 dB(A) |
||||
Topology |
Transformerless |
||||
Cooling concept |
Natural Cooling |
||||
Installation: Indoors/Outdoors (IP65 electronics) |
● /● |
||||
Features |
Graphic display: |
LCD |
|||
Interfaces: |
RS485/RS232 |
||||
SFENGINEER |
|||||
Warranty: |
5years |
||||
Certificates and approvals: |
www.sunfinepower.com |